Trade-UPS For Edge Computing

Welcome to Trade-UPS

APC Trade-UPS is a 1-phase UPS program that offers new and existing customers the ability to trade in older battery backup units for the most up-to-date 1-phase power protection models at discounted prices.

More about the program Program rules
Trade-in UPS summary
Number of trade-ins:0
Trade-in VA total:0 VA
New trade-UPS VA range
Trade-UPS target VA range
0 VA 0 VA
min. max.
New UPS summary
Number of new UPS(s):0
New UPS VA total:0 VA

SMARTSLOT EXPANSION CHASSIS

SMARTSLOT EXPANSION CHASSIS

AP9600

Additional Management Cards and Options Features & Benefits

  • Graceful System Shutdown, Shutdown and Reboot Parameters
    Immediate, graceful shutdown/restart of servers.
Product Distribution
Product Distribution

United Arab Emirates , Afghanistan , Antigua & Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Australia , Azerbaijan , Bosnia & Herzegovina , Barbados , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Bermuda , Bolivia , Brazil , Bahamas , Botswana , Belarus , Belize , Canada , Congo - Kinshasa , Switzerland , Côte d’Ivoire , Chile , Cameroon , China , Colombia , Costa Rica , Serbia and Montenegro , Cyprus , Czechia , Germany , Djibouti , Denmark , Dominica , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Eritrea , Spain , Ethiopia , Fiji , France , Gabon , Grenada , Georgia , French Guiana , Ghana , Gambia , Guadeloupe , Greece , Guatemala , Guyana , Hong Kong SAR China , Honduras , Croatia , Haiti , Hungary , Indonesia , Ireland , Israel , India , Iraq , Iceland , Italy , Jamaica , Jordan , Kenya , St. Kitts & Nevis , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , St. Lucia , Liberia , Lithuania , Luxembourg , Latvia , Morocco , Madagascar , North Macedonia , Mali , Myanmar (Burma) , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Malaysia , Mozambique , Namibia , Nigeria , Nicaragua , Netherlands , Norway , New Zealand , Oman , Panama , Peru , Philippines , Pakistan , Puerto Rico , Portugal , Paraguay , Réunion , Romania , Rwanda , Saudi Arabia , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Turks & Caicos Islands , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , Turkey , Trinidad & Tobago , Taiwan , Tanzania , Ukraine , Uganda , United States , Uruguay , Uzbekistan , St. Vincent & Grenadines , Venezuela , U.S. Virgin Islands , Vietnam , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Input

  • Number of Power Cords
    1

Physical

  • Maximum Height
    2.52inches ( 64MM , 6.4CM )
  • Maximum Width
    5.0inches ( 127MM , 12.7CM )
  • Maximum Depth
    5.24inches ( 133MM , 13.3CM )
  • Net Weight
    2.01lbs. ( 0.91KG )
  • Color
    Beige

Environmental

  • Operating Temperature
    32 - 104 °F ( 0 - 40 °C )
  • Operating Relative Humidity
    0 - 95 %
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Storage Temperature
    -15 - 65 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0 - 50000ft ( 0 - 15240meters )

Conformance

  • Approvals
    C-Tick, CE, DOC/Industry Canada, EN 55022 class B, FCC part 15 class B, VCCI
  • Standard warranty
    2 years repair or replace
Manuals and Warranties
Title
Size
Updated On
PDF

Size

3539KB

Updated On

2022-08-01

Expansion Chassis Installation Manual
Agency Approvals
Title
Size
Updated On
PDF

Size

58KB

Updated On

2024-02-22

VCCI and complies to VCCI EMC Emissions
PDF

Size

787KB

Updated On

2024-02-22

CE Emissions,CTICK,FCC Verified for Application Shutdown Utilities,Displays,Environmental Monitoring,Firmware Upgrades,Interface Cables,Interface Expander,Management Platform Integration,NetworkAir Data Guard 5,NetworkAir Data Guard,Open Source Software,Out-of-Band SmartSlot Card,Panelmount Environmental Monitoring,PowerChute Business Edition,PowerChute Inventory Manager,PowerChute Network Shutdown,PowerChute plus,PowerChute Personal Edition,PowerChute Software,Relay I/O,Remote Power Off Device,SmartSlot Expansion Chassis,SmartSlot Hub,Web/SNMP SmartSlot Cards,Wizards and Configurators and complies to EN 55022,VCCI EMC Emissions,FCC part 15,CS03,AS/NZS 3548,CISPR 22: 1985,EN55022:1987
Quick Sales Reference Sheet
Title
Size
Updated On
PDF

Size

208KB

Updated On

2022-08-01

This reference sheet provides product descriptions, use cases, benefits and compatibility information for APC UPS management cards and accessories (excludes UPS Network Management Cards)
Title
Size
Updated On

Category

Sub-Category


UPS Communications Cable Smart Signalling 6'/2m - DB9 to RJ45

UPS Cables that provide dedicated connections between APC UPSs and desktops, workstations, and servers

AP940-0625A
$24.25
UPS Communications Cable Smart Signalling 15' / 4.5m

UPS Cables that provide dedicated connections between APC UPSs and desktops, workstations, and servers

Extension Cable for use w/ UPS communications cable 15'/5m

UPS Cables that provide dedicated connections between APC UPSs and desktops, workstations, and servers

UPS Communications Cable Smart Signalling 15' / 4.5m - DB9 to RJ45

UPS Cables that provide dedicated connections between APC UPSs and desktops, workstations, and servers

AP940-1525A
$37.00
UPS Communications Cable Simple Signalling

UPS Cables that provide dedicated connections between APC UPSs and desktops, workstations, and servers

UPS Signaling Offer for IBM AS/400 and IBMi (IBM Power Systems)

UPS Cables that provide dedicated connections between APC UPSs and desktops, workstations, and servers

UPS Communications Cable Smart Signalling

UPS Cables that provide dedicated connections between APC UPSs and desktops, workstations, and servers


Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product