InRow DX 300mm 30kW

InRow DX 300mm 30kW

ACRD301

InRow DX 300mm 30kW
Discontinued

ACRD301 

InRow DX 300mm 30kW

  • Active Airflow Control
    Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
  • Active response control
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
  • Air filtration
    Removes dirt and other particulates from the intake air for cleaner supply air.
  • Architecturally neutral
    Unobtrusive design and coloring, blends in with the surroundings.
  • Capacity Control
    Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.
  • Casters
    Provides flexibility to move the unit to wherever cooling is required.
  • Containment system compatible
    The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency
  • Continuous current monitoring
    Permits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).
  • Direct drive motors
    Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
  • Ease of Use
    Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.
  • Easy to install
    Innovative design allows for fast, easy installation by almost anybody.
  • Efficiency
    Increases the capacity of the air conditioner by supplying a warmer return air temperature.
  • Electronic expansion valve
    Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
  • Electronically Commutated Fans
    Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
  • Enclosure system compatible
    Specifically designed to work with Netshelter Enclosures.
  • Fan guards
    A safety measure that provides protection from the fan opening by covering the inlet.
  • Fault-tolerant fan system
    In the event of a fan failure, the remaining fan(s) will continue to operate.
  • Field replaceable components
    Fans and electronics module can be readily replaced without uninstalling the unit.
  • Flexibility
    Support for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment
  • Front service access
    The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
  • Green Refrigerant
    Environmentally friendly refrigerant that can offer LEED points.
  • High Sensible-to-Total Cooling Ratio
    Achieved by careful sizing of heat exchanger coils.
  • Horizontal airflow pattern
    Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.
  • Increased capacity
    Higher rate of heat removal allows more equipment to be installed in each rack.
  • Local area network
    Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
  • Minimizes Air Mixing
    Delivers cool, conditioned air directly to the inlet of IT equipment.
  • Modular strategy
    Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expenditure and provides deferred investment throughout the life of the facility.
  • Network interface
    Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
  • Operational efficiency
    Warmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Predictive failure notification
    Maximizes system availability by providing early warning of required fan or filter replacement.
  • Programmable input/output contacts
    Allows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.
  • Rear containment
    Ensures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.
  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
  • Scalable Design
    Modular design provides scalable solutions to add cooling as demand increases.
  • Small Footprint
    Efficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.
  • Temperature Display
    Monitors and displays temperature to prevent overheating.
  • Touch-screen GUI
    Enables easy configuration, full monitoring, and event logging

Uniflair Direct Expansion InRow Cooling Features & Benefits

  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Building management system integration
    Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Microprocessor controller
    Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Real-Time capacity monitoring
    Real-time display of current and available cooling.
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Rack inlet temperature control
    Reduces the risk of hot spots at the rack level
  • Scalable densities
    Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Modular design
    Modular design provides scalable solutions to add cooling as demand increases.
Product Distribution
Product Distribution

United Arab Emirates , Afghanistan , Antigua & Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Australia , Azerbaijan , Bosnia & Herzegovina , Barbados , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Bermuda , Bolivia , Brazil , Bahamas , Botswana , Belarus , Belize , Canada , Congo - Kinshasa , Switzerland , Côte d’Ivoire , Cameroon , Colombia , Costa Rica , Cyprus , Czechia , Germany , Djibouti , Denmark , Dominica , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Eritrea , Spain , Ethiopia , Finland , Fiji , France , Gabon , Grenada , Georgia , French Guiana , Ghana , Gambia , Guadeloupe , Greece , Guatemala , Guyana , Hong Kong SAR China , Honduras , Croatia , Haiti , Hungary , Indonesia , Ireland , Israel , India , Iraq , Iceland , Italy , Jamaica , Jordan , Kenya , Cambodia , St. Kitts & Nevis , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , St. Lucia , Liberia , Lithuania , Luxembourg , Latvia , Morocco , Madagascar , North Macedonia , Mali , Myanmar (Burma) , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Malaysia , Mozambique , Namibia , Nigeria , Nicaragua , Netherlands , Norway , New Zealand , Oman , Panama , Peru , Philippines , Pakistan , Poland , Puerto Rico , Portugal , Paraguay , Qatar , Réunion , Romania , Rwanda , Saudi Arabia , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Turks & Caicos Islands , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , Turkey , Trinidad & Tobago , Taiwan , Tanzania , Ukraine , Uganda , United States , Uruguay , Uzbekistan , St. Vincent & Grenadines , Venezuela , U.S. Virgin Islands , Vietnam , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Input

  • Input frequency
    50/60 Hz
  • Power Feeds
    2.0
  • Input Power
    850 Watts
  • Maximum Overcurrent Protection
    25.0A
  • Minimum Circuit Amp Capacity
    20.0

Communications & Management

  • Control panel
    Multifunction LCD status and control console

Physical

  • Maximum Height
    78.39inches ( 1991MM , 199.1CM )
  • Maximum Width
    11.81inches ( 300MM , 30.0CM )
  • Maximum Depth
    43.11inches ( 1095MM , 109.5CM )
  • Rack Height
    42U
  • Net Weight
    352.7lbs. ( 159.98KG )
  • Shipping weight
    440.9lbs. ( 199.99KG )
  • Shipping Height
    84.72inches ( 2152MM , 215.2CM )
  • Shipping Width
    44.76inches ( 1137MM , 113.7CM )
  • Shipping Depth
    26.02inches ( 661MM , 66.1CM )

Environmental

  • Operating Temperature
    -13 - 104 °F ( -25 - 40 °C )
  • Operating Relative Humidity
    0 - 95 %
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Storage Temperature
    -20 - 50 °C
  • Audible noise at 1 meter from surface of unit
    77.1dBA

Conformance

  • Approvals
    CE, cUL listed, UL listed
  • Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up

General

  • Air Discharge Patterns
    Horizontal
  • Air Flow
    3400.0CFM ( 1604.62lps )
  • Compressor Type
    Scroll
  • Intake Air
    Rear return
  • Refrigerant Charge
    33.0pounds ( 14.97pounds )
Manuals and Warranties
Title
Size
Updated On
PDF

Size

182KB

Updated On

2024-04-03

Management Information Base
PDF

Size

341KB

Updated On

2024-04-03

Modbus Register Map: InRow DX ACRD301 ACRH301 Cooling Units
PDF

Size

1375KB

Updated On

2024-02-06

Installation procedure for the temperature and humidity sensor for the ACRD300 series of InRow DX units.
PDF

Size

6424KB

Updated On

2024-02-06

Technical specifications for the ACRD300 Series of cooling units. Information includes component identification, electrical specifications, and unit identification information.
PDF

Size

186KB

Updated On

2024-01-11

BACnet Application Map
PDF

Size

14379KB

Updated On

2023-09-29

Installation procedures for the ACRD300 Series of cooling units with ACCU30000 Series of condensing units.
PDF

Size

168KB

Updated On

2023-09-29

BACnet Application Map for ACRD300 Series firmware v.6.6.4.
PDF

Size

443KB

Updated On

2023-09-29

Modbus addressing information for the InRow ACRD300 series of cooling units
PDF

Size

502KB

Updated On

2023-09-29

Installation procedure for the ACAC10035 SKU accessory.
PDF

Size

2372KB

Updated On

2023-09-29

PDF

Size

138KB

Updated On

2023-09-29

Installation procedure for the ball valve and union accessory for the ACRD300 series of InRow DX units.
PDF

Size

231KB

Updated On

2023-09-29

Provides OIDs to developers.
PDF

Size

982KB

Updated On

2023-09-29

The Online Guide provides information on the Web user interface, various options to connecting to the unit, and how to update firmware.
PDF

Size

243KB

Updated On

2023-09-29

Installation procedure for the fan PSU.
PDF

Size

118KB

Updated On

2023-09-29

Release notes for v6.6.4 firmware for the ACRD300 series of cooling units.
Catalogs
Title
Size
Updated On
Brochure
Title
Size
Updated On
PDF

Size

918KB

Updated On

2023-09-29

One page overview of the InRow DX 300mm 25kW model with technical specifications and features
Agency Approvals
Title
Size
Updated On
PDF

Size

2703KB

Updated On

2024-02-22

CMIM Declaration of Conformity for InRow 300-mm Direct Expanstion Air Conditioner models ACRD301, ACRD301G, ACCU30201, ACCU30202
PDF

Size

254KB

Updated On

2024-02-22

PDF

Size

267KB

Updated On

2024-02-22

This is cULus listed certificate for InRow Air cooled 300mm Gen2 product
PDF

Size

606KB

Updated On

2024-02-22

This is InRow Air Cooled 300mm Gen2 product EMC Verification of Conformity
Title
Size
Updated On
Cooling Solutions, InRow Direct Expansion, Package
CAD Source File
9138KB
2023-10-04

BIM Models, Cooling Solutions, InRow RD

Category

Sub-Category


(1) Year Advantage Prime Service Plan for (1) In Row ACRD 300 and 301 series

Comprehensive service packages that allow you to design the coverage you need to operate your solution efficiently, minimize downtime and manage costs.

Warranty extension, for 14 to 30kW compressor, 1yr

Get an extension of factory warranty coverage beyond the original factory warranty term for peace of mind and protection from failure

1 Year On-Site Warranty Extension for (1) In Row ACRD 300 and 301 Series

Comprehensive service packages that allow you to design the coverage you need to operate your solution efficiently, minimize downtime and manage costs.

1 Year 4HR Response Upgrade to Existing Service Contract for (1) Cooling Product

Comprehensive service packages that allow you to design the coverage you need to operate your solution efficiently, minimize downtime and manage costs.

Custom quoted service contract

An APC factory trained technician will arrive on site to diagnose or repair your APC equipment

Start-up Service 5X8 for (1) In Row ACRD 300 and 301 series

A set of service options designed to deliver the vital resources, expertise, and tools needed to quickly and efficiently implement your APC by Schneider Electric solution

(1) Year Advantage Ultra Service Plan for (1) In Row ACRD 300 and 301 Series

Comprehensive service packages that allow you to design the coverage you need to operate your solution efficiently, minimize downtime and manage costs.

Start-up Service 7x24 for (1) In Row ACRD 300 and 301 Series

A set of service options designed to deliver the vital resources, expertise, and tools needed to quickly and efficiently implement your APC by Schneider Electric solution

Service On Demand (Micellaneous Services Provided on Request)

An APC factory trained technician will arrive on site to diagnose or repair your APC equipment