Condenser, 46kw, 95F/115F(35C/46C),230V/1, 60Hz , with CE

Share:

Condenser, 46kw, 95F/115F(35C/46C),230V/1, 60Hz , with CE

ACCD75233-C

Condenser, 46kw, 95F/115F(35C/46C),230V/1, 60Hz , with CE

null

Call for Availability
800-800-4272

ACCD75233-C 

Condenser, 46kw, 95F/115F(35C/46C),230V/1, 60Hz , with CE

  • Electronically Commutated Fans
    Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.

Uniflair Direct Expansion InRow Cooling Features & Benefits

  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Building management system integration
    Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Microprocessor controller
    Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Real-Time capacity monitoring
    Real-time display of current and available cooling.
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Rack inlet temperature control
    Reduces the risk of hot spots at the rack level
  • Scalable densities
    Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Modular design
    Modular design provides scalable solutions to add cooling as demand increases.
Product Distribution
Product Distribution

Afghanistan , Antigua & Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Australia , Azerbaijan , Bosnia & Herzegovina , Barbados , Bangladesh , Belgium , Burkina Faso , Bahrain , Burundi , Benin , Bermuda , Bolivia , Brazil , Bahamas , Botswana , Belarus , Belize , Canada , Congo - Kinshasa , Côte d’Ivoire , Chile , Cameroon , Colombia , Costa Rica , Serbia and Montenegro , Cyprus , Germany , Djibouti , Dominica , Dominican Republic , Ecuador , Eritrea , Ethiopia , Fiji , Gabon , Grenada , Georgia , French Guiana , Ghana , Gambia , Guadeloupe , Guatemala , Guyana , Honduras , Croatia , Haiti , Indonesia , India , Iraq , Iceland , Italy , Jamaica , Jordan , Kenya , Cambodia , St. Kitts & Nevis , South Korea , Kuwait , Cayman Islands , Lebanon , St. Lucia , Sri Lanka , Liberia , Luxembourg , Libya , Madagascar , Mali , Myanmar (Burma) , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Malaysia , Mozambique , Namibia , Nicaragua , Netherlands , New Zealand , Oman , Panama , Peru , Philippines , Pakistan , Puerto Rico , Paraguay , Qatar , Réunion , Rwanda , Singapore , Slovenia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Syria , Turks & Caicos Islands , Togo , Thailand , Tajikistan , Turkmenistan , Trinidad & Tobago , Tanzania , Uganda , United States , Uruguay , Uzbekistan , St. Vincent & Grenadines , Venezuela , U.S. Virgin Islands , Vietnam , Yemen , Mayotte , Zambia , Zimbabwe

Print Technical Specification

Input

  • Input frequency
    60 Hz
  • Input Power
    1440 Watts

Physical

  • Maximum Height
    52.91inches ( 1344MM , 134.4CM )
  • Maximum Width
    43.7inches ( 1110MM , 111.0CM )
  • Net Length
    6.86ft ( 2.1meters )
  • Maximum Depth
    82.28inches ( 2090MM , 209.0CM )
  • Net Weight
    297.62lbs. ( 135.0KG )
  • Shipping weight
    330.69lbs. ( 150.0KG )
  • Shipping Height
    55.0inches ( 1397MM , 139.7CM )
  • Shipping Width
    90.0inches ( 2286MM , 228.6CM )
  • Shipping Depth
    50.0inches ( 1270MM , 127.0CM )

Environmental

  • Operating Temperature
    -4 - 122 °F ( -20 - 50 °C )
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Audible noise at 1 meter from surface of unit
    56.6dBA

Conformance

  • Approvals
    CE
  • Standard warranty
    1 year (parts only)

Sustainable Offer Status

  • RoHS
    Compliant
  • Proposition 65 Warning
    Available in Documentation tab

General

  • Air Discharge Patterns
    Horizontal, Upflow
  • Air Flow
    11000.0CFM ( 5191.42lps )
  • Amp Draw In-Rush
    6.0A
  • Return Diameter
    0.87inches ( 22.0MM )
Design/Configuration
Title
Size
Updated On
PDF

Size

4538KB

Updated On

2023-10-04

InRow DX Gen 2 Technical Specifications
Title
Size
Updated On
Cooling Solutions, Chillers & Heat Rejection, Condensers
CAD Source File
8179KB
2023-10-04