Easy Rack PDU, Switched Metered Outlet, 0U, 1 Phase, 3.7kW, 230V, 16A, (20) C13 and (4) C19 outlets, IEC60309 2P+E inlet

Easy Rack PDU, Switched Metered Outlet, 0U, 1 Phase, 3.7kW, 230V, 16A, (20) C13 and (4) C19 outlets, IEC60309 2P+E inlet Front Straight
Easy Rack PDU, Switched Metered Outlet, 0U, 1 Phase, 3.7kW, 230V, 16A, (20) C13 and (4) C19 outlets, IEC60309 2P+E inlet Front Straight
Easy Rack PDU, Switched Metered Outlet, 0U, 1 Phase, 3.7kW, 230V, 16A, (20) C13 and (4) C19 outlets, IEC60309 2P+E inlet Front Straight
Easy Rack PDU, Switched Metered Outlet, 0U, 1 Phase, 3.7kW, 230V, 16A, (20) C13 and (4) C19 outlets, IEC60309 2P+E inlet Front Straight
  • Easy Switched Rack Power Distribution Units (Rack PDU) provide on/off outlet switching, advanced power management, load monitoring and much more features than the ...

  • Includes: Installation guide

View Product Overview

EPDU2116SMBO Features

Key Features

Output Connections
(20) IEC 60320 C13
Nominal Output Voltage
230V
Nominal Input Voltage
200V
Input Connections
IEC 60309, IEC 60309 16 A 2P + E
Cord Length
3meters
Easy Rack PDU, Switched Metered Outlet, 0U, 1 Phase, 3.7kW, 230V, 16A, (20) C13 and (4) C19 outlets, IEC60309 2P+E inlet
Easy Switched Rack Power Distribution Units (Rack PDU) provide on/off outlet switching, advanced power management, load monitoring and much more features than the average power strip.
Includes: Installation guide

Easy Switched Rack PDU Features & Benefits

Manageability

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Outlet Power Sequencing
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released.
Network Port Sharing
Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series.
Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time.

Adaptability

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Product Distribution

United Arab Emirates, Argentina, Austria, Australia, Belgium, Bulgaria, Brazil, Switzerland, Chile, China, Serbia and Montenegro, Czechia, Germany, Denmark, Algeria, Estonia, Egypt, Spain, Finland, France, United Kingdom, Greece, Hong Kong SAR China, Croatia, Hungary, Indonesia, Ireland, Israel, Italy, Kazakhstan, Lithuania, Latvia, Morocco, North Macedonia, Malaysia, Nigeria, Netherlands, Norway, New Zealand, Peru, Philippines, Poland, Portugal, Romania, Saudi Arabia, Sweden, Singapore, Slovenia, Slovakia, Thailand, Tunisia, Turkey, Taiwan, Ukraine, Vietnam, South Africa

Technical Specifications

Output

Overload Protection
No
Cord Length
3meters
Maximum Total Current Draw
16

Input

Input frequency
50/60 Hz
Acceptable Input Voltage
200 - 240VAC
Number of Power Cords
1
Load Capacity
3680VA
Maximum Input Current
16A
Maximum Line Current
16A
Regulatory Derated Input Current (North America)
16A

Physical

Maximum Height
1800MM, 180.0CM
Maximum Width
55MM, 5.5CM
Maximum Depth
56MM, 5.6CM
Net Weight
6.67KG
Shipping weight
7.84KG
Shipping Height
2030MM, 203.0CM
Shipping Width
195MM, 19.5CM
Shipping Depth
130MM, 13.0CM
Color
Black

Environmental

Operating Temperature
-5 - 50 °C
Operating Relative Humidity
5 - 95 %
Operating Elevation
0 - 3000meters
Storage Temperature
-25 - 65 °C
Storage Relative Humidity
5 - 95 %
Storage Elevation
0 - 15000000meters

Conformance

Approvals
CE
Standard warranty
2 Years repair and Replace