3.5kW split system Indoor unit, Gravity Drain

3.5kW split system Indoor unit, Gravity Drain Front Left
3.5kW split system Indoor unit, Gravity Drain Front Left
3.5kW split system Indoor unit, Gravity Drain Front Left
3.5kW split system Indoor unit, Gravity Drain Front Left
3.5kW split system Indoor unit, Gravity Drain Front Right
3.5kW split system Indoor unit, Gravity Drain Front Right
3.5kW split system Indoor unit, Gravity Drain Front Straight
3.5kW split system Indoor unit, Gravity Drain Front Straight
3.5kW split system Indoor unit, Gravity Drain Back
3.5kW split system Indoor unit, Gravity Drain Back
3.5kW split system Indoor unit, Gravity Drain Front Left
3.5kW split system Indoor unit, Gravity Drain Front Left
3.5kW split system Indoor unit, Gravity Drain Front Right
3.5kW split system Indoor unit, Gravity Drain Front Right
3.5kW split system Indoor unit, Gravity Drain Front Straight
3.5kW split system Indoor unit, Gravity Drain Front Straight
3.5kW split system Indoor unit, Gravity Drain Back
3.5kW split system Indoor unit, Gravity Drain Back
  • Rack Mounted cooling solution to meet the specific needs of Micro Data Center and Edge computing solutions

  • Includes: 120/240 V power supply, Built-in modbus protocol adapter

View Product Overview

ACRMD4KI-1 Features

Key Features

Rack Height
5U
3.5kW split system Indoor unit, Gravity Drain
Rack Mounted cooling solution to meet the specific needs of Micro Data Center and Edge computing solutions
Includes: 120/240 V power supply, Built-in modbus protocol adapter
  • Active response control
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Air filtration
    Removes dirt and other particulates from the intake air for cleaner supply air.
  • Automatic restart
    Returns the unit to its last operating status in the event of a power failure.
  • Capacity metering
    Measures how much IT load is being cooled by the unit in real time.
  • Compressors
    Scroll and screw compressors utilize few moving parts for increased reliability and life expectancy
  • Counterflow cooling coil
    Designed for high-sensible heat ratios, the coil is constructed with copper tubes, raised lance type aluminum fins, and 18 gauge galvanized steel end plates. Coil headers are equipped with anti-drip shields in the event of condensation.
  • Dehumidification
    Dehumidification is achieved without any reduction in airflow rate, ensuring continuous and uniform air distribution.
  • Ease of Use
    Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Easy to install
    Innovative design allows for fast, easy installation by almost anybody.
  • Efficiency
    Increases the capacity of the air conditioner by supplying a warmer return air temperature.
  • Eliminates Air Mixing
    Isolates hot exhaust air, ensuring consistent supply air to IT equipment.
  • High performance technological solutions
    Optimize the unit operation at any load or ambient condition, guaranteeing an extremely low power consumption
  • Increased capacity
    Higher rate of heat removal allows more equipment to be installed in each rack.
  • Minimizes Air Mixing
    Delivers cool, conditioned air directly to the inlet of IT equipment.
  • Modulating compressors
    Part loading of compressors during start-up ensures low starting torque on the mechanical system with lower inrush current on the electrical system. (only for IS** and BC** models)
  • No minimum heat load requirement
    Refrigerant cooling system will operate from 0 - 100% of the design capacity
  • Noise dampening
    Containment of both front and rear provides reduction of noise caused by installed equipment.
  • Promotes Proper Airflow
    Helps to maintain proper rack temperatures within the enclosure by promoting top to bottom airflow movement.
  • Quick restart
    Full load operation in less than 3 minutes with specific arrangements permits undersizing of the storage tanks
  • Scalable Design
    Modular design provides scalable solutions to add cooling as demand increases.
  • Top or Bottom Piping Connections
    The unit includes both top and bottom piping connections.
  • Variable frequency drives
    Enables the fans to be soft started, saving energy during power up. Controlling the motor speed simplifies the adjustment for static pressure and gives the option of back-draft prevention.
  • Variable Speed Control
    Controls fan speed based on temperature with selectable set points.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Washable filters
    Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

Uniflair Rack Mounted Room Cooling Features & Benefits

Adaptability

Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Vendor-neutral Solution
Installs and integrates quickly and simply at the bottom of the IT rack. Ideal for existing/retrofit racks as well as new, pre-integrated racks.
Easy to install
Innovative design allows for fast, easy installation by almost anybody.

Total cost of Ownership

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
Powerfully Compact
One unit provides precise temperature control to cool single racks of IT equipment without the need of any additional cooling systems.
Rack Mount Installation
Frees up valuable IT floor space by placing the IT cooling at the bottom of any IT rack.

Availability

Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Redundant Components
Single points of failure in the system have redundant components to maintain availability and reliability.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Operational Service
Allows critical components to be maintained/replaced while the system is in operation.

Product Distribution

United Arab Emirates, Afghanistan, Antigua & Barbuda, Anguilla, Albania, Armenia, Netherlands Antilles, Angola, Argentina, Austria, Australia, Azerbaijan, Bosnia & Herzegovina, Barbados, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, Bermuda, Bolivia, Brazil, Bahamas, Botswana, Belarus, Belize, Congo - Kinshasa, Switzerland, Côte d’Ivoire, Chile, Cameroon, China, Colombia, Costa Rica, Serbia and Montenegro, Cyprus, Czechia, Germany, Djibouti, Denmark, Dominica, Dominican Republic, Algeria, Estonia, Egypt, Eritrea, Spain, Ethiopia, Finland, Fiji, France, Gabon, United Kingdom, Grenada, Georgia, French Guiana, Ghana, Gambia, Guadeloupe, Greece, Guatemala, Guyana, Honduras, Croatia, Haiti, Hungary, Indonesia, Ireland, Israel, India, Iraq, Iceland, Italy, Jamaica, Jordan, Kenya, Cambodia, St. Kitts & Nevis, South Korea, Kuwait, Cayman Islands, Kazakhstan, Lebanon, St. Lucia, Liberia, Lithuania, Luxembourg, Latvia, Morocco, Madagascar, North Macedonia, Mali, Myanmar (Burma), Mongolia, Martinique, Mauritania, Malta, Mauritius, Malawi, Mexico, Malaysia, Mozambique, Namibia, Nigeria, Nicaragua, Netherlands, Norway, New Zealand, Oman, Panama, Peru, Philippines, Pakistan, Poland, Puerto Rico, Portugal, Paraguay, Qatar, Réunion, Romania, Rwanda, Saudi Arabia, Sweden, Singapore, Slovenia, Sierra Leone, Senegal, Somalia, Suriname, El Salvador, Turks & Caicos Islands, Togo, Thailand, Tajikistan, Turkmenistan, Tunisia, Turkey, Trinidad & Tobago, Tanzania, Ukraine, Uganda, Uruguay, Uzbekistan, St. Vincent & Grenadines, U.S. Virgin Islands, Vietnam, Yemen, Mayotte, South Africa, Zambia, Zimbabwe

Technical Specifications

Input

Input frequency
50 Hz
Power Feeds
1.0

Physical

Maximum Height
218MM, 21.8CM
Maximum Width
474MM, 47.4CM
Maximum Depth
752MM, 75.2CM
Net Weight
26.0KG
Shipping weight
30.0KG
Shipping Height
330MM, 33.0CM
Shipping Width
950MM, 95.0CM
Shipping Depth
580MM, 58.0CM

Environmental

Audible noise at 1 meter from surface of unit
62.5dBA

Conformance

Approvals
CCC, CE
Standard warranty
1 year repair or replace

General

Air Discharge Patterns
Upflow
Air Flow
193.5lps
Compressor Type
Scroll
Intake Air
Rear return

Options

Services