{}

Our Brands

Search FAQs
ACPA4000 Spare Parts List
Issue:
ACPA4000 Spare Parts List

Product line:
ACPA4000

Environment:
All Serial Numbers

Cause:
Parts

Resolution:
Please contact Cooling Tech Support to confirm the part numbers before quoting as some may have changed. 888-695-6500 Option 2, Option 2, Option 2

DescriptionAPC PN#
ASSY PUMP CONDENSATE WITH FLOAT0N-0228A
CABLE POWERVIEW ACPA (cable from CAT-5e coupler to Display)0W1621
CAP MTL PPR 20UF 10% 370VAC -20C TO 70C (condenser) QTY 3234-4206
CAP MTL PPR 45UF 10% 370VAC (compressor) QTY 2234-0456
CASTER 50MM LOCKING (REAR)870-3787
CASTER FRONT BARROW (FRONT)870-3520
Ceiling Tile Adapter (for drop ceiling)870-3641A
CKT BRKR 20A 250VAC UL/VDE (Rear of the unit)530-0850
COIL COND 18 X 15 2ROW 14 FPI (condenser coil)875-0428B
COIL EVAP 14 X 13.50 2 ROW (evaporator coil)875-0427A
COMPLETE 872 PCB ASSY NPOLE (Barrow - Brain Board)W0P4576
COMPLETE 873 PCB ASSY NPOLE (Powerboard - all 120v comes through here)W0P4577
COMPLETE 878 PCB ASSY NPOLE (supply/return temperature sensor)0P4582
COMPRESSOR ROTARY 115/1/60 (PANASONIC style compressor) (CAT2P16S3R126B-1A)875-3544
Condensate Drain hose (PVC Tube .125IN ID .250IN OD)875-0481
Condensate Drain QUICK DISCONNECT COUPLER Sub Assembly (rear drain disconnect)0M-2725
Condensate Pump Door Assy (Includes Pump)[do not rma]0M-6326A
Condensate Pump EC-400 Little Giant (YK0501 below) (this pump only)491-0464
Condensate Pump Pacific Yellow PCF3000.4 (YK0501 above) (120V/230V - AutoSelect)
(you need to ship this with the water sensor pn#W0H-0213 )
W0N-7166
Condensate Tray with Dual float (actual condensate tray)870-3640
Condenser Duct Tubing (Assy. Intake/Exhaust DUCT 10 FT X 8 IN)0M-2411
Condenser Exhaust Kit (includes hose connectors & ceiling tile)0M-2470
Condenser Fan (fan only)490-1045
Condenser Fan Box Sub Assy (fan housing assy)0M-5034B (0M2483)
CONN PLUG 12 POS 3.5MM (connects to Barrow Control Board)715-0105
DEFLECTOR ROOF ADAPTER ACPA (ceiling air deflector)870-3662
DISCHARGE BYPASS ADRI-1-1 _4- 0_ 75 (HGBP)W875-4198
Duct Collars (connects ducts to the unit and ceiling)870-3663
Evaporator Fan Box Assy (fan only)490-1046
Evaporator Fan Box Sub Assy (fan w/ housing assy)0M-5033A
Filter 16 x 16 x 2 (air filter kit; ships w/3 filters)ACPA4000RF
Filter 16 x 16 x 2 (individual)875-2145
Filter Drier (Liquid Line Filter Drier) (C-033-S)875-2131
Float Switch (dual floats)540-0097
FLOAT SWITCH, BULKHEAD MOUNT (single float)540-0205
HARNESS BOARD INTERCONNECT ACPA0W1618C
HARNESS For POWER VIEW (connects to powerview from board)0W1623
HIGH PRESSURE SWITCH (CO 350 PSI CI 250 PSI)540-0087
LABEL POWERVIEW NETWORKAIR885-1577
LEUR CHECK VALVE ASSEMBLY (condensate pump check valve assy)0M-6332
LUER CHECK VALVE ACPA (condensate pump check valve)870-11676
PowerView Display (a.k.a. thermostat, display, controller, interface, control pad)AP9231E
Pwr Cord, 20A, 100-120V, C19 to 5-20 (OPTIONAL Power Cord w/out GFCI)AP9873
Pwr Cord, 20A, 100-120V, C19 to L5-20 (OPTIONAL Power Cord)AP9874
Pwr Cord, 20A, 100-120V, Spare Part (White w/ GFCI)0W3401
Pwr Cord, 3M IEC309-16A TO C19 V-LOCK (OPTIONAL Power Cord Black)960-0121
Quick connect for drain (condensate drain line on the rear of the unit)0M-2726
Quick Disconnect Body (condensate pump) 875-0854
RELAY 120V/15A SPDT 120V COIL (Evaporator) (AZ2280-1C-120A)450-0001
Replacement Breaker (Unit Circuit Breaker)530-1200
SWITCH DIFFERENTIAL PRESSURE 0-2 INWG P232 (air differential pressure switch)540-0088
Switch Thermal Overload Protector (for compressor pecker head)540-0128
TELECOUPLNG 8P8C RJ45 STRAIGHT (ethernet telecoupler)W750-0034
Temperature & Humidity Sensor (Remote)AP9512THBLK
TEV SPORLAN BBIVE-1-CP100-B20 (BBIVE-1-CP100-B20)875-4199A
TUBE TWIN INSERT 1/8" (O-ring) (condensate pump) 875-0853
Water Carry-Over-Kit (Air Dam kit 870-0656)0M-0844
Water Sensor Kit For ACPA4000
(you need to ship this with the condensate pump pn# W0N-7166)
W0H-0213
WIRE HARNESS 10" SMART-SLOT (connects NMC to the brain board)0W0436
Services Description:Price:
1 Year Extended Warranty for NetworkAir ACPA4000 (WEXTWAR1YR-AX-12)$369.99
LABEL HOLD FOR FAILURE ANALYSIS885-3997















APC USA

Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: