Issue:
Password error: unable to log on to PowerChute Network Shutdown web UI due to unknown username or password.
Product:
PowerChute Network Shutdown (PCNS) v3.X and 4.X
Environment:
All supported Operating Systems.
Cause:
Lost/unknown username or password
Solution:
To change your username or password:
Notes:
For security, the password line will be deleted from the pcnsconfig.ini file when the PowerChute service is restarted.
The new password must meet the password requirements laid out in the PowerChute Network Shutdown user manual or this process may fail.
Password error: unable to log on to PowerChute Network Shutdown web UI due to unknown username or password.
Product:
PowerChute Network Shutdown (PCNS) v3.X and 4.X
Environment:
All supported Operating Systems.
Cause:
Lost/unknown username or password
Solution:
To change your username or password:
1. Stop the PowerChute service.
On Windows open a command prompt as an administrator and enter the command net stop pcns1
On Linux enter from command window enter sudo service PowerChute stop
On Linux enter from command window enter sudo service PowerChute stop
2. Go to the group1 directory where PowerChute is installed.
On Windows the default path is
C:\Program files\APC\PowerChute\group1
On Linux the default path is
/opt/APC/PowerChute/group1
C:\Program files\APC\PowerChute\group1
On Linux the default path is
/opt/APC/PowerChute/group1
3. Make a backup of the pcnsconfig.ini file - copy it to another directory and rename it to pcnsconfig-backup.ini.
4. Open pcnsconfig.ini in a text editor.
5. In the [NetworkManagementCard] section of the INI file, set the following lines with your new values:
username= new user name
password= new password
6. Save pcnsconfig.ini.
7. Start the PowerChute service and log in with your new username and password.
On Windows open a command prompt as an administrator and enter the command net start pcns1
On Linux enter from command window enter sudo service PowerChute start
On Linux enter from command window enter sudo service PowerChute start
Notes:
For security, the password line will be deleted from the pcnsconfig.ini file when the PowerChute service is restarted.
The new password must meet the password requirements laid out in the PowerChute Network Shutdown user manual or this process may fail.