Flooded Receiver, 20L, 219mm diameter, 640mm length, ASME with heater

Flooded Receiver, 20L, 219mm diameter, 640mm length, ASME with heater Front Left
Flooded Receiver, 20L, 219mm diameter, 640mm length, ASME with heater Front Left
Flooded Receiver, 20L, 219mm diameter, 640mm length, ASME with heater Front Left
Flooded Receiver, 20L, 219mm diameter, 640mm length, ASME with heater Front Right
  • Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers

View Product Overview

ACAC75014 Features

Flooded Receiver, 20L, 219mm diameter, 640mm length, ASME with heater
Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers

InRow Direct Expansion Features & Benefits

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Agility

Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Modular design
Modular design provides scalable solutions to add cooling as demand increases.

Total Cost of Ownership

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Availability

Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Rack inlet temperature control
Reduces the risk of hot spots at the rack level
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Manageability

Microprocessor controller
Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
Real-Time capacity monitoring
Real-time display of current and available cooling.
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Product Distribution

Canada, United States

Physical

Maximum Height
9.41inches (239MM, 23.9CM)
Maximum Width
9.41inches (239MM, 23.9CM)
Maximum Depth
25.98inches (660MM, 66.0CM)
Net Weight
85.98lbs. (39.0KG)
Shipping weight
150.0lbs. (68.04KG)
Shipping Height
14.96inches (380MM, 38.0CM)
Shipping Width
16.14inches (410MM, 41.0CM)
Shipping Depth
43.5inches (1105MM, 110.5CM)
Color
Black

Environmental

Operating Temperature
-4 - 122 °F (-20 - 50 °C)
Operating Elevation
0-10000ft (0-3000meters)

Options