Row CW 600mm 42U 1200mm Deep,380V,Dual feed, Cond pump,Humid control
-
Close-coupled, chilled water cooling for medium to large data centers
-
Includes: Installation guide, Operations and maintenance manual, User manual
ERC611CD0HPE Features
Key Features
Rack Height
42U
Row CW 600mm 42U 1200mm Deep,380V,Dual feed, Cond pump,Humid control
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation guide, Operations and maintenance manual, User manual
-
Capacity Control
Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.
-
Casters
Provides flexibility to move the unit to wherever cooling is required.
-
Condensate Pump
A condensate pump is factory wired and piped internally to the internal condensate drain pan.
-
Dual power inputs
(Optional) Dual power supplies for incoming power redundancy
-
Electronically Commutated Fans
Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
-
Humidifier
Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.
-
Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
-
Scalable Design
Modular design provides scalable solutions to add cooling as demand increases.
-
Top and bottom chilled water connections
Provide flexibilty in installation based on the constraints of a given area.
-
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
-
Washable filters
Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
Easy Cooling Row CW Features & Benefits
Adaptability
Redundant fans
In the event of fan failure, redundant fans will provide increased airflow.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Top and bottom chilled water connections
Provide flexibilty in installation based on the constraints of a given area.
Casters
Provides flexibility to move the unit to wherever cooling is required.
Active Airflow Control
Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
Flexibility
Support for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment
Dual power inputs
(Optional) Dual power supplies for incoming power redundancy
Serviceability
Microprocessor controller
The system is controlled by a microprocessor, with an 80-character LCD backlit alphanumeric display, that provides communication and alarm indication.
Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Washable filters
Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
Total cost of Ownership
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
Capacity Control
Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.
Product Distribution
United Arab Emirates, Argentina, Austria, Australia, Belgium, Bulgaria, Brazil, Switzerland, Chile, China, Colombia, Costa Rica, Czech Republic, Germany, Denmark, Algeria, Estonia, Egypt, Spain, Finland, France, Greece, Hong Kong, Croatia, Hungary, Indonesia, Ireland, Israel, India, Italy, Japan, South Korea, Kazakhstan, Lithuania, Latvia, Morocco, Macedonia, Mexico, Malaysia, Nigeria, Netherlands, Norway, New Zealand, Peru, Philippines, Poland, Portugal, Romania, Russia, Saudi Arabia, Sweden, Singapore, Slovenia, Slovakia, Thailand, Tunisia, Turkey, Taiwan, Ukraine, Vietnam, South Africa
Input
Input frequency
50 Hz
Power Feeds
2.0
Communications & Management
Control panel
7" touch screen display
Physical
Maximum Height
2000MM, 200.0CM
Maximum Width
600MM, 60.0CM
Maximum Depth
1200MM, 120.0CM
Net Weight
225.0KG
Shipping weight
255.0KG
Shipping Height
2190MM, 219.0CM
Shipping Width
720MM, 72.0CM
Shipping Depth
1320MM, 132.0CM
Conformance
Standard warranty
1 year on-site repair or replace with factory authorized Start-Up