APC Back-UPS 575VA, 120V, AVR, LAM, 6 NEMA outlets (2 surge)
BX575U-LM Features
Key Features
Run time for load
Min-max
W
Run time for load
Enter the total load (power draw) of all devices to be protected by the UPS here. Based on the value entered we will estimate the run time that you will have during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.
—
The total load (power draw) entered exceeds the maximum value for this product (320 W)
Please enter load to see estimated run time
The total load (power draw) entered is less than the minimum value for this product ({} W)
Max. Capacity Used
Max. Capacity Used
The maximum percentage of UPS capacity used to support your specified load.
—
Please enter load to see calculated "Max. Capacity Used"
Output power capacity
320 Watts
/ 575VA
Output Connections
(2)
NEMA 5-15R
(Surge Protection)
(4)
NEMA 5-15R
(Battery Backup)
Nominal Output Voltage
120V
Nominal Input Voltage
120V
Input Connections
NEMA 5-15P
Cord Length
1.5meters
Maximum Input Current
12.0A
APC Back-UPS 575VA, 120V, AVR, LAM, 6 NEMA outlets (2 surge)
Battery Backup & Surge Protector for Electronics and Computers
-
Audible alarms
Provides notification of changing utility power and UPS power conditions
-
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
-
Cold-start capable
Provides temporary battery power when the utility power is out.
-
Disconnected battery notification
Warns when a battery is not available to provide backup power.
-
Overload protection
Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
-
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
-
Telephone dataline surge protection
Provides protection of connected equipment from power surges traveling on telephone lines.
-
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Back-UPS Features & Benefits
Marketing features
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Manageability
LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Availability
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Product Distribution
Anguilla, Netherlands Antilles, Aruba, Barbados, Bermuda, Bahamas, Belize, Costa Rica, Dominican Republic, Ecuador, Guatemala, Honduras, Haiti, Italy, Jamaica, Mexico, Nicaragua, Panama, Puerto Rico, Reunion, El Salvador, Turks And Caicos Islands, Togo, Venezuela, U.S. Virgin Islands
Output
Max Configurable Power (Watts)
320 Watts
/ 575VA
Output Frequency (sync to mains)
50/60 Hz +/- 1 Hz Sync to mains, 50/60 Hz +/- 1 Hz Unsynchronised
Topology
Line interactive
Waveform type
Square wave
Maximum Output Current
12
Output Voltage Tolerance
+/- 1% static and +/- 5% at 100% load step
Transfer Time
6 ms typical : 10 ms maximum
Input
Input frequency
47 - 63 Hz
Input voltage range for main operations
78 - 150V
Number of Power Cords
1
Type of Input Protection Required
3-pole circuit breaker
Batteries & Runtime
Battery type
Lead-acid battery
Included Battery Modules
1
Typical recharge time
6hour(s)
Replacement Battery
Expected Battery Life (years)
3 - 5
Battery Charge Power (Watts)
13 Watts
Runtime
Communications & Management
Control panel
LED status display with on line : on battery : replace battery and overload indicators
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating
273Joules
Data Line Protection
RJ11 modem/fax protection
Physical
Maximum Height
279MM, 27.85CM
Maximum Width
160MM, 16.0CM
Maximum Depth
89MM, 8.85CM
Net Weight
5.2KG
Shipping weight
5.4KG
Shipping Height
399MM, 39.9CM
Shipping Width
215MM, 21.5CM
Shipping Depth
128MM, 12.8CM
Color
Black
Master Carton Dimensions (Length x Width x Height)
406 x 279 x 254MM
Master Carton Units
2.0
Master Carton Weight
11.88
SCC Codes
10731304310096
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0 - 3048meters
Storage Temperature
-15 - 45 °C
Storage Relative Humidity
0 - 95 %
Audible noise at 1 meter from surface of unit
45.0dBA
Conformance
Approvals
UL 1778
Standard warranty
3 years repair or replace
Sustainable Offer Status
RoHS
Compliant