Specifications
Lead time | Usually in Stock |
---|
Run time for load WEnter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Min-max: 66-660 W | |
---|---|
Max. Capacity Used The maximum percentage of UPS capacity used to support your specified load. | |
Main Input Voltage | 230 V |
Rated power in W | 660 W |
Rated power in VA | 1100 VA |
output connection type | 2 IEC 60320 C13 4 universal receptacle |
Cable length | 1.22 m |
number of cables | 2 |
Battery type | Lead-acid battery |
provided equipment | 1, detachable 1.2 m IEC power cord 1, detachable 2.0 m NEMA 5-15P to IEC C13 power cord |
---|---|
product web sub-family | Entry level |
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | No |
Height | 21.5 cm |
---|---|
Width | 13 cm |
Depth | 33.6 cm |
Net weight | 12 kg |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
Two post mountable | 0 |
USB compatible | No |
network frequency | 50/60 Hz +/- 3 Hz auto-sensing |
---|---|
input voltage limits | 150...280 V |
Maximum input current | 5 A |
Switching current capacity | 10 A |
input current | 5 A (1 phase) |
Maximum configurable power in W | 660 W |
---|---|
output frequency | 50/60 Hz +/- 3 Hz sync to mains 50/60 Hz +/- 1 Hz unsynchronised |
UPS type | Line interactive |
Wave type | Stepped approximation to a sinewave |
Maximum configurable power in VA | 1100 VA |
Transfer time | 8 ms typical : 10 ms maximum |
Equipment protection policy | No EPP for ASEAN |
---|
Ambient air temperature for operation | 0…40 °C |
---|---|
relative humidity | 0…95 % |
Operating altitude | 0...10000 ft |
Ambient air temperature for storage | -15…40 °C |
storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…9144.00 m |
Run Time | View Runtime Graph |
---|---|
Efficiency | View Efficiency Graph |
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Battery recharge time | 8 h |
battery charger power | 19 W rated |
Battery power in VAH | 156 VAh runtime |
Battery life | 2…4 year(s) |
Replacement battery | APCRBC113 |
Extended runtime | 0 |
control panel | LED status display with on line : on battery : replace battery and building wiring fault |
---|---|
alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge energy rate | 273 J |
---|---|
Noise suppression | Full time multi-pole noise filtering : 10% of IEEE surge let-through : zero clamping response time: instantaneous |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 29.48 cm |
Package 1 Width | 24.51 cm |
Package 1 Length | 43.993 cm |
Package 1 Weight | 12.946 kg |
SCC14 | 10731304303197 |
Warranty | 2 years repair or replace |
---|
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance.
Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn more
Resource performance
Energy efficient product
Take-back program available
Well-being performance
Mercury free
Certifications & Standards
REACh Regulation
EU RoHS Directive
Environmental Disclosure
Circularity Profile
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.
BX1100CI-MS is replaced by: