The APC Computer Interface Port
- Document Date: 03/05/2004
- Reference: SPD_TDOY-5UQVBL_EN
- Description: This application note provides technical information regarding APC UPS computer interface ports...
- Size: 765.8 kb
- Version: V1
- Language: English
-
Practices for Pressure Relief Valve Discharge Piping
- Document Date: 06/04/2007
- Reference: SPD_KSIH-6Y6TEA_EN
- Description: Many mechanical refrigeration systems containing large quantities of refrigerant possess pressure relief devices...
- Size: 188.3 kb
- Version: V0
- Language: English
-
Modbus Register Map: Uniflair Rack Mounted Room Cooling ACRMD4Kxxx 990-91589
- Document Date: 21/02/2022
- Reference: Modbus_Register_Map_990-91589
- Size: 268.5 kb
- Version: 1.0
- Language: English
-
ACRP Requirements for Selecting 3rd Party Remote Air-Cooled Condenser and Flooded Receiver
- Document Date: 30/03/2007
- Reference: SPD_KSIH-6Y6SJP_EN
- Description: The InfraStruXure InRow RP (ACRP100, ACRP101, and ACRP102) is an air-cooled DX air conditioner for data centers...
- Size: 497 kb
- Version: V0
- Language: English
-
Modular PDU Slot Locks
- Document Date: 10/03/2016
- Reference: SPD_ACOS-9L8QVZ_EN
- Description: This application note explains the purpose of Schneider Electric Modular PDU slot locks and Schneider Electric service policy for electrical work...
- Size: 1.3 mb
- Version: V1
- Language: English
-
USB HID Implementation in Smart-UPS
- Document Date: 19/08/2013
- Reference: SPD_MPAO-99NQF6_EN
- Description: This App Note explains how to manage the behaviour of the Smart-UPS and its outlets through a custom application making use of USB connectivity.
- Size: 591.5 kb
- Version: V1
- Language: English
-
Modbus Installation and Troubleshooting for AP9635/41/43/44 Network Management Card
- Document Date: 21/01/2022
- Reference: SPD_AKAR-8KETBK_EN
- Description: This application note explains how to install the Modbus wiring for an AP9635/41/43/44 Network Management Card, gives an overview of the Modbus...
- Size: 710.4 kb
- Version: V3
- Language: English
-
Smart-UPS configuration application note
- Document Date: 18/04/2005
- Reference: SPD_AKOV-699KQK_EN
- Description: Smart-UPS and Smart-UPS XL behavior can be flexibly adjusted to the actual operating condition through an extended set of user-configurable...
- Size: 3.1 mb
- Version: V0
- Language: English
-
Smart-UPS Communications
- Document Date: 10/07/2019
- Reference: SPD_MPAO-9E5RB5_EN
- Description: This document outlines the various connection options available in the Smart-UPS products to communicate with your PC or server
- Size: 2.7 mb
- Version: V2
- Language: English
-
Rack Air Containment Application Guidelines and Approved Configurations
- Document Date: 25/03/2011
- Reference: SPD_KDUP-6LERQJ_EN
- Description: The Rack Air Containment System (RACS) is a modular front and rear plenum for use in isolating the supply and return air between an APC Netshelter SX...
- Size: 565.1 kb
- Version: V3
- Language: English