Protect computers, wireless routers, IOT devices, and security systems with the APC Back-UPS 550VA. APC Back-UPS provide backup battery power during power outages and continuously safeguard devices from fluctuating power conditions and surges. With 8 outlets, this desktop UPS (uninterruptible power supply) provides seamless battery power to connected electronics. The 330w capacity is ideal for workstations, keeping you connected and productive during power fluctuations. This battery backup is designed to power wireless home networking devices (router and modem) for hours during utility outages so you can stay connected and productive. This computer backup offers lifetime guaranteed surge protection with a $75,000 equipment protection policy. The side of this 550VA UPS includes 2 keyhole sockets to easily mount the battery backup on a wall in hard to reach installations. The outlets are arranged with spaces to accommodate both average sized power plugs and transformer block power plugs. Use the included PowerChute software to configure settings and set up automatic graceful shutdown of a connected PC in the event of an extended power outage. Audible alarms provide notification of changing utility power and UPS conditions. Audible alarms can be muted. Package Contains UPS, user manual
arrow2_down

Specifications

Overview
Lead timeUsually in Stock
Main
Run time for load
W
information_circle
Enter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.
Min-max: 33-330 W
Max. Capacity Used
information_circle
The maximum percentage of UPS capacity used to support your specified load.
Main Input Voltage120 V
Main Output Voltage120 V
Kw Rating330 W
Rated power in VA550 VA
plug standardNEMA 5-15P
output connection type4 NEMA 5-15R
4 NEMA 5-15R surge
Cable length5 ft (1.52 m)
number of cables1
Battery TypeLead-Acid battery
provided equipmentUser Manual
USB cable
General
Number of power module free slots0
Number of power module filled slots0
RedundantNo
Physical
colorBlack
Height3.46 in (8.8 cm)
Width7.09 in (18 cm)
Depth11.89 in (30.2 cm)
Net Weight12.13 lb(US) (5.5 kg)
Mounting LocationFront
mounting preferenceNo preference
Mounting ModeNot rack-mountable
Two post mountable0
USB compatibleYes
Input
Input Frequency50/60 Hz +/- 3 Hz auto-sensing
Efficiency at full load88...139 V
Output
Max Configurable Power (Watts)330 W
Output Frequency (sync to mains)50/60 Hz +/- 3 Hz sync to mains
TopologyStandby
Waveform TypeStepped approximation to a sinewave
Maximum configurable power in VA550 VA
Transfer Time8ms typical : 12ms maximum
Conformance
Product CertificationsCalifornia (CEC) Battery Charger
ENERGY STAR V2.0 (USA)
NOM
TÜV-C
Equipment protection policyLifetime : $75000
Environmental
Ambient Air Temperature for Operation32…104 °F (0…40 °C)
Relative Humidity5…95 %
Operating altitude0...10000 ft
Ambient Air Temperature for Storage5…113 °F (-15…45 °C)
Storage Relative Humidity5…95 %
Storage altitude0…50000 ft (0.00…15240.00 m)
Acoustic level45 dBA
Heat dissipation16 Btu/h
Batteries & Runtime
Run TimeView Runtime Graphaction_new_window
EfficiencyView Efficiency Graphaction_new_window
Included Battery Modules0
Battery Slots Empty0
Typical recharge time24 h
RBC Quantity1
Battery Charge Power (Watts)3 W rated
Battery power in VAH82 VAh runtime
Battery life3…5 year(s)
Replacement batteryAPCRBC110action_new_window
Battery graph commentsThis graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several variables including battery age, battery charge level, environmental conditions and characteristics of the connected load.
Extendable Run Time0
Communications & Management
control panelLED status display with On Line : On Battery : Replace Battery and Building Wiring Fault
alarmAlarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating340 J
FilteringFull time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : mee
Data Line ProtectionRJ45 10/100 Base-T Ethernet protection
Let Through Voltage Rating330 V
Ordering and shipping details
Category11309 - APC RESALE PRODUCTS
GTIN00785901258940
ReturnabilityNo
Country of originPH
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.04 in (12.8 cm)
Package 1 Width15.47 in (39.3 cm)
Package 1 Length9.25 in (23.5 cm)
Package 1 Weight13.67 lb(US) (6.2 kg)
Package 3 Weight1503.16 lb(US) (681.82 kg)
SCC1410731304258947
Pallet unit layers20
Pallet layers5
Contractual warranty
Warranty3 years repair or replace
arrow2_down

Sustainability

Green premium brand logo
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn morearrow2_left
Resource performance

Energy efficient product

notification_ok

Take-back program available

notification_ok
Well-being performance

Mercury free

notification_ok

RoHS exemption information

External labels

ENERGY STAR UPS V2.0 (USA)

REACh Regulation

EU RoHS Directive

Environmental Disclosure

Circularity Profile

California proposition 65

WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

arrow2_down

Documents

arrow2_down

Software and Firmware

Need more information? Check our technical FAQs!

Easily find answers to the most frequently asked questions.