CKT BKR 3 P 20a 480vac ... CKT BKR 3 P K 16A ... CKT BKR 3 P K 20a ... CKT BRKR 3 P 100a 600v ... CKT BRKR 3 P 150a 600v ... CKT BRKR 3 P 25A 480v ... CKT BRKR 3 P 30a 600v ... CKT BRKR 3 P 40a 480v ... CKT BRKR 3 P 40a 600v ... CKT BRKR 3 P 50a 600v ... CKT BRKR 3 P 60a 480v ... CKT BRKR 3 P 70a 600v ... ... FIX SOLUTION # 3 ... 24V 50/ 60hz - MKC- ... ... 24V 50/ 60hz - MKC- ... ... PUMP HIGH LIFT 208 - 230v
What are the operational conditions for an InRoom (Stulz) Unit
Outdoor ambient conditions: Lower limit: -10°C (14°F) Upper limit: Depending on selected condenser ... 208 - 230v / 3ph / 60 Hz ... Voltage imbalance: < 3 % ... Maximum equivalent length of piping between the cooling unit and the air cooled condenser : 60 m (200 ft) Maximum level difference between the condenser and the cooling unit: 5 m (16 ft) when the condenser is below the cooling unit
APC Schneider Cooling Unit Identification
... Economizer BA= 208 -230/ 3 /60 ... = 480/ 3 /60 ... = 600/ 3 /60 E ... A= 3 row 20 BA= 208 -230/ 3 /60 ... = 480/ 3 /60 ... = 600/ 3 /60 AA= 208 / 208 / 3 /60 ... =480/ 208 / 3 /60 ... /480/ 3 /60 ... =600/ 208 / 3 /60 F ... ... = 600/ 3 /60 AA= 208 / 208 / 3 /60
acpa4000 Spare Parts List
... TO 70c ( condenser ) QTY 3 ... (120v/ 230v - AutoSelect ... 870-3640 Condenser Duct Tubing ( ... ... M-2411 Condenser Exhaust Kit ( ... 0M-2470 Condenser Fan (fan only 490-1045 Condenser Fan Box Sub Assy (fan housing assy 0M-5034b (0m2483) CONN PLUG 12 POS 3 .5MM (connects to Barrow Control Board ... 0M-5033a Filter 16 x 16 x 2 (air filter kit; ships w/ 3 filters ... 0w3401 Pwr Cord, 3 M iec309-16A TO C19 V-LOCK (OPTIONAL Power Cord Black
ACRP1XX, ACRD5XX, ACRP5XX, and ACRC5XX Parts List
... 0989 ADPTR PIPE 3 " ENGL TO ... ... , GAS SHUTOFF 3 /4" ... ... Cable Main Power 208 /400v For ... 208 VAC 3 Phase - Spare ... VAC 3 Phase - Spare ... ... r0357 Circuit Breaker 3 P 10a 280v ... r0457 Circuit Breaker 3 P 10a 480v ... r0427 Circuit Breaker 3 P 15A 480v ... r0457 Circuit Breaker 3 P 20a 240v ... r0487 Circuit Breaker 3 P 30a 240v ... r0527 Circuit Breaker 3 P 30a 480v ... t1n030tl Circuit Breaker 3 P 50a 480v ... t1n050tl Circuit Breaker 3 P 50a 280v ... t1n050tl Circuit Breaker 3 P 5A ...
ACSC1XX Spare Parts List
... SC, ROTARY 208 -230/ ... COMP, ROTARY 208 -230/1/60, SC, TOSHIBA - SPARE PART ... Condenser Fan 200mm Mixed Flow (INDIVIDUAL FAN) ... 3 ... 3 ... ELECTRONIC EXPANSION VALVE, 3 /8" ODF (HGBP) ... 3 ... 3 ... FILTER-DRIER 3 /8"ODF SOLDER ... GROMMET RUBBER 1 1/2"ID X 1 3 /4"GD X 1/8"GW (for power cable at the bottom) ... 3 ... 3 ... TXV VALVE 3 /8"ODM X 5/8" ODF r410a 1.5 TON
What is the input voltage required for the InRow ACRD?
The InRow ACRD unit uses a single phase 208v/ 60hz input in NAM and a 230v /50hz input in the rest of the ...
What is the input voltage required for the InRow acrd100/200? Is a power cord supplied with the unit?
The InRow RD unit uses a single phase 208v/ 60hz input in NAM and a 230v /50hz input in the rest of the ...
Are the fans in a 600mm Cooling unit single phase or 3-phase?
Resolution: 3 Phase either 208 -230vac, or 460vac