Stacking limitations for single phase Symmetra and Matrix products
... available with the single phase Symmetra and Matrix family ... Symmetra and Matrix UPS Symmetra LX products in tower form factor were ... When stacking Symmetra LX products, please ... - One ( 1 ) SYBFXR9 can ... a 8kva or 16kva Symmetra LX chassis using the ... ... stacking options, APC always recommends the ... APC offers Symmetra LX Tower systems with integrated ... ... before purchasing the Symmetra LX UPS. Symmetra Power Array Products ... 1 SY4KEX on bottom, 1 SYXR4 on top ... Cabinet or SYMSTRF 16kva UPS Systems. 1 SmartcellXR on bottom, 1 mx3000pe/mx5000pe on top 1 mx3000pe/mx5000pe on bottom, 2 Smartcells (not XRs) on top
Why does my 8kva Symmetra LX system have a sticker on the back that specifies 100 amp input?
8kva Symmetra LX systems have a ... Symmetra LX Symmetra LX systems scalable to a maximum ... ... for an 8kva Symmetra LX frame to have ... ... the 8kva and 16kva Symmetra LX systems ship with ... means that each system's internal wiring is rated for 100 amps despite the fact that the 8kva LX must be put on a 50a circuit for proper over-current protection. ... The 8kva LX system requires the customer to install a 50 amp circuit breaker to feed the UPS. Refer to the Electrical Installation manual under the Documentation tab of the product page on apc .com.
Which service bypass panel should be used for single phase Symmetra UPS systems?
Hardwire Symmetra LX 200, 208 , 240v ; Power Array 240 Input; 12k RM 200, 208 , 240v
Are Symmetra LX Intelligence Modules Universal?
... -phase ( 208 / 240v ) Symmetra LX models as well as 3: 1 / 1 : 1 (220/230/ 240v or 380/ ... /415V) Symmetra LX models.
Hardwiring to 120v, 208v, and 240v loads from a 208v/240v SmartUPS RT UPS
... 208v, and 240v loads from a 208v/ 240v SmartUPS RT UPS ... for 208v/ 240v environments have unbalanced ... ... The 208v/ 240v Smart-UPS RT is a single phase UPS with ... ... you will see 208 volts (or 240v if so configured ... from 208v/ 240v utility power. ... measure 208v or 240v . ... be configured to 240v via the network ... ... down transformers, APC manufactures 3 larger ... ... To supply a 208 v load, ... ... you would measure 208 volts from Hot ... Symmetra LX ... If a 208v / 120v output panel is required you must use one of our split phase solutions.
Description of NEMA L6-30 Receptacle
... on the domestic APC Matrix-UPS ... models, and Symmetra RM 2-6kva UPS. The NEMA L6-30 receptacle is also used as an output receptacle for supplying 208 VAC in the Matrix-UPS, the Smart-UPS T models, and single phase Symmetra systems (Power Array, RM, LX ). ... When used with APC's UPS models, the receptacle will generally provide either 208v or 240v (depending on the UPS model). ... X= L 1 (Hot)
Converting Symmetra LX to and from rackmount and tower configuration
Symmetra LX APC by Schneider Electric ... UPS or a tower UPS at purchase ... ... to modify the Symmetra . ... from rackmount to tower form factor. CONVERTING FROM TOWER TO RACK- ... ... : SYAOPT1 - Symmetra LX rack mount 4 ... contact APC Customer Support ... to convert a Symmetra LX tower to a rack ... APCs recommendation is that an APC certified field service ... ... -MOUNT TO TOWER : ( 1 ) SYAFSU8 - Symmetra LX top panel ... ) SYAFSU6 - Symmetra LX castors (left ... ... ) SYAFSU7 - Symmetra LX castors (right ...
Symmetra LX Spare Parts List
... parts for the APC Symmetra LX UPS system? Symmetra LX ... for servicing a Symmetra LX UPS. ... Spare parts for 208 /240 VAC Symmetra LX systems ( Symmetra system part numbers ... Symmetra LX 4 kVA Power ... APC Symmetra LX Battery Module - ... APC Symmetra LX Battery Module with ... APC Symmetra LX Intelligence Module - ... Symmetra LX Four-Post ... Symmetra LX / Symmetra RM Two- ... Symmetra LX frame electronics module ... Symmetra LX Input/Output ... Symmetra LX Communications Card - ... Symmetra LX 13 U replacement ... Symmetra LX 19 U replacement ... Symmetra LX 32 U replacement ...
Information on Online and On Battery operation of 3:1 Symmetra UPS systems
... of 3: 1 Symmetra UPS systems? Symmetra Power Array Symmetra LX 3: 1 (International) ... ... of 3: 1 Symmetra UPS systems When a Symmetra 3: 1 is operating On ... ... with a maximum 16KVA load. ... and converted to single phase and sent ... The Symmetra 3: 1 will run On ... If any one of the phases fails, the Symmetra will still operate ... ... , then the Symmetra will go to ... When Symmetra 3: 1 is On Battery it will provide single phase output power ...
Powerview displays Rev. N, please wait or does not communicate with the UPS
Symmetra Power Array Symmetra RM Symmetra LX ... name from the Symmetra Main Intelligence module ... ... PowerView Rev. N please wait. ... as to what APC UPS it is ... ... UPS is a Symmetra LX , a faulty ... ... not possible with Symmetra RM or Symmetra Power Array because ... ... UPS is a Symmetra LX , connect the ... ... located on the Symmetra Communication Card at ... Reseat the Symmetra Communication Card to ... ... UPS is a Symmetra LX , disable the ... The Symmetra Communication card can ... ... 8 none, 1 . Flow control ... ... PCB of the Symmetra . If assistance is required with these troubleshooting steps, contact APC by Schneider Electric technical support.