+ 13
APC Symmetra LX 16kVA Scalable to 16kVA N+1 Tower, 220/230/240V or 380/400/415V
SYA16K16I
Environmental performance of the product Learn more
Sustainable by Design
Compatible Software
Specifications
Presentation | High performance, redundant power protection with scalable power and runtime for space-constrained server rooms, and voice and data networks. |
---|---|
Lead time | Usually in Stock |
Run time for load WEnter the total load (power draw) of all devices that will be protected by the UPS. This will be used to estimate the run time of your devices during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Min-max: 1120-11200 W | |
---|---|
Max. Capacity Used The maximum percentage of UPS capacity used to support your specified load. | |
Main Input Voltage | 230 V 400 V 3 phases |
Other Input Voltage | 220 V 240 V 380 V 415 V |
Main Output Voltage | 230 V |
Other Output Voltage | 220 V 240 V |
Rated power in W | 11200 W |
Rated power in VA | 16000 VA |
Output connector type | Hard wire 3-wire (H N + E) 1 |
Battery type | Lead-acid battery |
Provided equipment | CD with software Documentation CD Installation guide User manual Web/SNMP management card |
product web sub-family | 4kVA power increments |
---|---|
Number of power module free slots | 1 |
Number of power module filled slots | 4 |
Redundant | Yes |
Colour | Black Silver |
---|---|
Height | 93.7 cm |
Width | 48.3 cm |
Depth | 72.6 cm |
Net weight | 307.73 kg |
Mounting location | Front |
Mounting preference | No preference |
Mounting mode | Not rack-mountable |
Two post mountable | 0 |
USB compatible | No |
Network frequency | 45...65 Hz auto-sensing |
---|---|
Number of input connectors | 1 hard wire 3-wire (1P + N + E) 1 hard wire 5-wire (3P + N + E) |
Input voltage limits | 155...276 V 290...480 V 3:1 |
Input harmonic distortion | Less than 7 % for full load |
Input Power Factor at Full Load | 0.98 |
Maximum configurable power in W | 11200 W |
---|---|
Harmonic distortion | Less than 5 % at full load |
Output frequency | 47...63 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
Crest factor | Up to 5 : 1 |
UPS type | Double conversion online |
Wave type | Sine wave |
Bypass type | Internal bypass (automatic and manual) |
Maximum output current | 73 A |
Maximum configurable power in VA | 16000 VA |
Product certifications | C-Tick CE GOST VDE |
---|---|
Standards | EN 50091-1 EN 50091-2 EN 55022 class A EN 55024 EN 60950 IEC 60950 |
Ambient air temperature for operation | 0…40 °C |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0...10000 ft |
Ambient air temperature for storage | -15…45 °C |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…4572.00 m |
Acoustic level | 62 dBA |
Heat dissipation | 3707 Btu/h |
Run Time | View Runtime Graph |
---|---|
Efficiency | View Efficiency Graph |
Number of battery filled slots | 4 |
Number of battery free slots | 0 |
Battery recharge time | 3 h |
Additional information | Configurable for 220 : 230 or 240 nominal output voltage |
Battery charger power | 1148 W rated |
Battery power in VAH | 3456 VAh runtime |
Battery life | 3…5 year(s) |
Battery option | SYAXR9B9I 1 11232 VAh SYAXR9B9I 2 19008 VAh SYAXR9B9I 3 26784 VAh SYAXR9B9I 4 34560 VAh SYAXR9B9I 5 42336 VAh SYAXR9B9I 6 50112 VAh SYAXR9B9I 7 57888 VAh |
Extended runtime | 1 |
Free slots | 1 |
---|---|
Preinstalled device | Network management card 2 with environmental monitoring |
Control panel | Multifunction LCD status and control console |
Alarm | Audible and visible alarms : prioritized by severity |
Emergency power off | Yes |
Unit Type of Package 1 | Db |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 118.1 cm |
Package 1 Width | 59.9 cm |
Package 1 Length | 99.7 cm |
Package 1 Weight | 337.73 kg |
Warranty | 2 years repair or replace |
---|
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance.
Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products.
Learn more
Resource performance
Energy efficient product
Take-back program available
Well-being performance
Mercury free
Certifications & Standards
REACh Regulation
EU RoHS Directive
WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Documents
Software and Firmware
Need more information? Check our technical FAQs!
Easily find answers to the most frequently asked questions.