APC Back-UPS ES 8 Outlet 550VA 120V

Best Seller
APC Back-UPS ES 8 Outlet 550VA 120V Front Left
APC Back-UPS ES 8 Outlet 550VA 120V Front Left
APC Back-UPS ES 8 Outlet 550VA 120V Front Left
APC Back-UPS ES 8 Outlet 550VA 120V Front Left
APC Back-UPS ES 8 Outlet 550VA 120V Back
APC Back-UPS ES 8 Outlet 550VA 120V Detailed
Green Premium™
RoHS
  • Battery Backup & Surge Protector for Electronics and Computers

  • Includes: USB cable, User Manual

View Product Overview
Our Partners
Sorry, currently we don't have additional content for this product, but we are working on it.
Want additional product information?
Load the product overview with videos, comparison and features.

BE550G Features

APC Back-UPS ES 8 Outlet 550VA 120V
Battery Backup & Surge Protector for Electronics and Computers
Includes: USB cable, User Manual
  • Building Wiring Fault Indicator
    This LED informs users of potentially dangerous wiring problems in the wall circuit.
  • Cold-start capable
    Provides temporary battery power when the utility power is out.
  • Dataline surge protection
    Provides protection of connected equipment from power surges on the data lines.
  • Disconnected battery notification
    Warns when a battery is not available to provide backup power.
  • Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Lifetime data recovery warranty
    Provides peace of mind by providing professional data recovery services in the event data is lost due to the failure of the unit.
  • Simple battery replacement
    Increases UPS availability by allowing quick, easy battery replacement.
  • Transformer-block spaced outlets
    Protect equipment with input transformer blocks without blocking access to other receptacles.
  • USB connection
    Use your PC to access additional power protection and management features for your UPS via a USB Port.

Back-UPS Features & Benefits

Availability

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Protection

Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

Safety

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Manageability

LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions

Marketing Features

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Product Distribution

Anguilla, Netherlands Antilles, Aruba, Barbados, Bermuda, Bahamas, Belize, Canada, Dominican Republic, Falkland Islands, Guyana, Haiti, Jamaica, Cayman Islands, Puerto Rico, Trinidad and Tobago, United States, U.S. Virgin Islands

Output

Output power capacity
330Watts / 550VA
Max Configurable Power (Watts)
330Watts / 550VA
Nominal Output Voltage
120V
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Topology
Standby
Waveform type
Stepped approximation to a sinewave
Output Connections
(4) NEMA 5-15R (Battery Backup)
(4) NEMA 5-15R (selector_surgetitle)
Transfer Time
8ms typical : 12ms maximum

Input

Nominal Input Voltage
120V
Input frequency
50/60 Hz +/- 3 Hz (auto sensing)
Input Connections
NEMA 5-15P
Cord Length
5ft (1.52meters)
Input voltage range for main operations
88 - 139V
Number of Power Cords
1

Batteries & Runtime

Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time
24hour(s)
Replacement Battery
Expected Battery Life (years)
3 - 5
RBC Quantity
1
Battery Volt-Amp-Hour Capacity
82

Communications & Management

Interface Port(s)
USB
Control panel
LED status display with On Line : On Battery : Replace Battery and Building Wiring Fault
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

Surge energy rating
340Joules
Data Line Protection
RJ45 10/100 Base-T Ethernet protection
Filtering
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449

Physical

Maximum Height
3.46inches (88MM, 8.8CM)
Maximum Width
7.09inches (180MM, 18.0CM)
Maximum Depth
11.89inches (302MM, 30.2CM)
Net Weight
12.1lbs. (5.5KG)
Shipping weight
13.64lbs. (6.2KG)
Shipping Height
5.04inches (128MM, 12.8CM)
Shipping Width
9.25inches (235MM, 23.5CM)
Shipping Depth
15.47inches (393MM, 39.3CM)
Color
Black
Master Carton Dimensions (Length x Width x Height)
16inches (405MM)
Master Carton Units
2.0
Master Carton Weight
28.6lbs. (13.0)
# of Layers per Pallet
5.0
# of Units per Layer per Pallet
20.0
Pallet Weight
1500.0lbs.
Units per Pallet
64.0
SCC Codes
1073130425894 7

Environmental

Operating Temperature
32 - 104 °F (0 - 40 °C)
Operating Relative Humidity
5 - 95 %
Operating Elevation
0-10000ft (0-3000meters)
Storage Temperature
-15 - 45 °C
Storage Relative Humidity
5 - 95 %
Storage Elevation
0-50000ft (0-15000meters)
Audible noise at 1 meter from surface of unit
45.0dBA
Online thermal dissipation
16.0BTU/hr

Conformance

Approvals
California (CEC) Battery Charger, ENERGY STAR V2.0 (USA), FCC Part 15 Class B, FCC Part 68, NOM, TUV-C, UL 497A, UL 497B, UL 1778
Equipment protection policy
Lifetime : $75000
Standard warranty
3 years repair or replace

Sustainable Offer Status

RoHS
Compliant
REACH
REACH: Contains No SVHCs
PEP
Available in Documentation tab
EOLI
Available in Documentation tab
Proposition 65 Warning
Available in Documentation tab

Options

Services