Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15

Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Left
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Left
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Left
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Left
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Right
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Right
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Straight
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Back
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Detailed
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Left
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Left
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Right
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Right
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Front Straight
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Back
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 Detailed
  • Switched Rack Power Distribution Units (Rack PDU) provide advanced load management plus on/off control at the outlet level for power cycling, delayed power sequencing ...

  • Includes: Cord retention bracket(s), Horizontal mounting brackets, Installation guide, User manual

View Product Overview
Our Partners

AP7900B Features

Key Features

Rack Height
1U
Output Connections
(8) NEMA 5-15R
Nominal Output Voltage
120V
Nominal Input Voltage
100V, 120V
Input Connections
NEMA 5-15P
Cord Length
12ft (3.7meters)
Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15
Switched Rack Power Distribution Units (Rack PDU) provide advanced load management plus on/off control at the outlet level for power cycling, delayed power sequencing, and outlet use management.
Includes: Cord retention bracket(s), Horizontal mounting brackets, Installation guide, User manual

NetShelter Switched Rack PDUs Features & Benefits

Marketing features

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Adaptability

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.

Manageability

Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Multi-tier user access
Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.
Network port sharing
Allows four rack PDUs to be connected using In and Out ports so that only one network connection is necessary.
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Product Distribution

Antigua and Barbuda, Anguilla, Netherlands Antilles, Argentina, Aruba, Barbados, Bermuda, Bolivia, Bahamas, Belize, Canada, Chile, Colombia, Costa Rica, Czech Republic, Dominica, Dominican Republic, Ecuador, France, Grenada, Greece, Guatemala, Guyana, Honduras, Haiti, Jamaica, Japan, Saint Kitts And Nevis, Cayman Islands, Saint Lucia, Mexico, Nicaragua, Panama, Peru, Puerto Rico, Paraguay, Slovakia, El Salvador, Trinidad and Tobago, Taiwan, United States, Uruguay, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands

Technical Specifications

Output

Maximum Total Current Draw
15

Input

Input frequency
50/60 Hz
Acceptable Input Voltage
100 - 120VAC
Number of Power Cords
1
Load Capacity
1440VA
Maximum Input Current
15A
Regulatory Derated Input Current (North America)
12A

Physical

Maximum Height
1.7inches (44MM, 4.4CM)
Maximum Width
17.5inches (445MM, 44.5CM)
Maximum Depth
4.3inches (108MM, 10.8CM)
Net Weight
5.0lbs. (2.27KG)
Shipping weight
7.61lbs. (3.45KG)
Shipping Height
2.8inches (70MM, 7.0CM)
Shipping Width
18.5inches (470MM, 47.0CM)
Shipping Depth
13.5inches (343MM, 34.3CM)
Color
Black

Environmental

Operating Temperature
32 - 113 °F (0 - 45 °C)
Operating Relative Humidity
0 - 95 %
Operating Elevation
0 - 10000ft (0 - 3048meters)
Storage Temperature
-25 - 65 °C
Storage Elevation
0 - 50000ft (0 - 15240meters)

Conformance

Approvals
CUL listed, FCC part 15 class A, ICES-003, UL listed
Standard warranty
2 years repair or replace