InRow RC, 600mm, Chilled Water, 460-480V, 60Hz

InRow RC, 600mm, Chilled Water, 460-480V, 60Hz Front Left
InRow RC, 600mm, Chilled Water, 460-480V, 60Hz Front Left
InRow RC, 600mm, Chilled Water, 460-480V, 60Hz Front Left
InRow RC, 600mm, Chilled Water, 460-480V, 60Hz Front Right
InRow RC, 600mm, Chilled Water, 460-480V, 60Hz Front Straight
InRow RC, 600mm, Chilled Water, 460-480V, 60Hz Back
InRow RC, 600mm, Chilled Water, 460-480V, 60Hz is rated 5.0 out of 5 by 1.
  • y_2019, m_7, d_22, h_22
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.13
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_ACRC601, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_apc
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 307ms
  • REVIEWS, PRODUCT
Rated 5 out of 5 by from Efficient and effective We used a number of these in a large datacenter deployment with many cooling issues. These were efficient and run effectively in our customer's site while maintaining necessary temps.
Date published: 2019-01-23
  • y_2019, m_7, d_22, h_22
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.13
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_ACRC601, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_apc
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 138ms
  • REVIEWS, PRODUCT
  • Close-coupled, chilled water cooling for medium to large data centers

  • Includes: Installation guide, Operations and maintenance manual

View Product Overview

ACRC601 Features

InRow RC, 600mm, Chilled Water, 460-480V, 60Hz
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation guide, Operations and maintenance manual

InRow Chilled Water Cooling Features & Benefits

Manageability

Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time Capacity Monitoring
Real-time display of current and available cooling.
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.

Agility

Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Casters
Provides flexibility to move the unit to wherever cooling is required.
Modular design
Modular design provides scalable solutions to add cooling as demand increases.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Total Cost of Ownership

Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Availability

Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.

Product Distribution

Antigua and Barbuda, Anguilla, Netherlands Antilles, Aruba, Barbados, Bermuda, Brazil, Belize, Canada, Colombia, Costa Rica, Cuba, Dominican Republic, Ecuador, Falkland Islands, Guatemala, Guyana, Honduras, Jamaica, Mexico, Nicaragua, Panama, Peru, Puerto Rico, El Salvador, Trinidad and Tobago, United States, Venezuela, U.S. Virgin Islands