In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16

In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Left
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Left
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Left
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Left
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Right
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Straight
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Back
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
  • Close-coupled, chilled water cooling for medium to large data centers

  • Includes: Installation Guide, Operations and Maintenance Manual

View Product Overview

ACRC103 Features

In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation Guide, Operations and Maintenance Manual
  • Hot swappable fans
    Allows system to remain operational if a fan replacement is required.
  • Washable filters
    Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

InRow Chilled Water Cooling Features & Benefits

Total Cost of Ownership

Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Agility

Casters
Provides flexibility to move the unit to wherever cooling is required.
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Modular design
Modular design provides scalable solutions to add cooling as demand increases.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Manageability

Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Real-Time Capacity Monitoring
Real-time display of current and available cooling.

Availability

Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Product Distribution

Andorra, Afghanistan, Albania, Armenia, Angola, Argentina, Austria, Australia, Azerbaijan, Bosnia and Herzegovina, Bangladesh, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, Brunei, Bhutan, Botswana, Belarus, Canada, Central African Republic, Congo, Switzerland, Côte d'Ivoire, Cook Islands, Chile, Cameroon, China, Serbia and Montenegro, Cyprus, Czech Republic, Germany, Djibouti, Denmark, Algeria, Estonia, Egypt, Western Sahara, Eritrea, Spain, Ethiopia, Finland, Fiji, France, Gabon, United Kingdom, Georgia, Ghana, Gibraltar, Gambia, Guinea, Equatorial Guinea, Greece, Hong Kong, Croatia, Hungary, Indonesia, Ireland, Israel, India, Iraq, Iran, Iceland, Italy, Jordan, Japan, Kenya, Cambodia, South Korea, Kuwait, Cayman Islands, Kazakhstan, Lebanon, Liechtenstein, Sri Lanka, Liberia, Lesotho, Lithuania, Luxembourg, Latvia, Morocco, Moldova, Macedonia, Mali, Myanmar, Mongolia, Mauritania, Malta, Malaysia, Mozambique, Namibia, Niger, Nigeria, Netherlands, Norway, Nepal, New Zealand, Oman, Papua New Guinea, Philippines, Pakistan, Poland, Portugal, Romania, Russia, Rwanda, Sudan, Sweden, Singapore, Slovenia, Slovakia, Sierra Leone, Senegal, Somalia, Suriname, Chad, Togo, Thailand, Tajikistan, Turkmenistan, Tunisia, TP, Turkey, Taiwan, Tanzania, Ukraine, Uganda, United States, Uzbekistan, Vietnam, XF, Yemen, South Africa, Zambia, Zimbabwe

Input

Nominal Input Voltage
200V
Input frequency
50/60 Hz
Input Connections
IEC 309 16A 2P+E
Number of Power Cords
2
Input Power
1000.0Watts

Communications & Management

Control panel
Multi-function LCD status and control console
Audible Alarm
Audible and visible alarms prioritized by severity

Physical

Maximum Height
78.39inches (1991MM, 199.1CM)
Maximum Width
11.8inches (300MM, 30.0CM)
Maximum Depth
42.13inches (1070MM, 107.0CM)
Rack Height
42U
Net Weight
358.0lbs. (162.73KG)
Shipping weight
425.5lbs. (193.41KG)
Shipping Height
83.39inches (2118MM, 211.8CM)
Shipping Width
29.38inches (746MM, 74.6CM)
Shipping Depth
44.75inches (1137MM, 113.7CM)
Color
Black
Units per Pallet
1.0

Conformance

Approvals
C-tick, CE, EN 55022 Class A, EN 55024, EN 60950, GOST, IEC 60950, IEC 61000-3-2, IEC 61000-3-3, MEA, VDE
Standard warranty
1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

General

Air Discharge Patterns
Horizontal
Air Flow
2900.0CFM (1368.64lps)
Condensate Pump Capacity
1.3gal/hour (0.002lps)
Intake Air
Rear Return
Minimum Water Inlet Temperature
45.0 °F (7.0 °C)

Options

Services