APC Back-UPS 650VA, 120V,1 USB charging port, Retail

APC Back-UPS 650VA, 120V,1 USB charging port, Retail Front Left
APC Back-UPS 650VA, 120V,1 USB charging port, Retail Front Left
APC Back-UPS 650VA, 120V,1 USB charging port, Retail Front Left
APC Back-UPS 650VA, 120V,1 USB charging port, Retail Front Right
APC Back-UPS 650VA, 120V,1 USB charging port, Retail Front Straight
APC Back-UPS 650VA, 120V,1 USB charging port, Retail Miscellaneous
APC Back-UPS 650VA, 120V,1 USB charging port, Retail Front Left
APC Back-UPS 650VA, 120V,1 USB charging port, Retail Front Right
APC Back-UPS 650VA, 120V,1 USB charging port, Retail Front Straight
APC Back-UPS 650VA, 120V,1 USB charging port, Retail Miscellaneous
  • Battery Backup & Surge Protector for Electronics and Computers

View Product Overview

BVN650M1 Features

Key Features

Run time for load
Min-max
W
Run time for load
Enter the total load (power draw) of all devices to be protected by the UPS here. Based on the value entered we will estimate the run time that you will have during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.

The total load (power draw) entered exceeds the maximum value for this product (360 W)

Please enter load to see estimated run time

The total load (power draw) entered is less than the minimum value for this product ({} W)

Max. Capacity Used
Max. Capacity Used
The maximum percentage of UPS capacity used to support your specified load.

Please enter load to see calculated "Max. Capacity Used"

Output power capacity
360 Watts / 650VA
Output Connections
(2) NEMA 5-15R (Surge Protection)
(5) NEMA 5-15R (Battery Backup)
Nominal Output Voltage
120V
Nominal Input Voltage
120V
Input Connections
NEMA 5-15P
APC Back-UPS 650VA, 120V,1 USB charging port, Retail
Battery Backup & Surge Protector for Electronics and Computers
  • Adjustable voltage sensitivity
    Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • Audible alarms
    Provides notification of changing utility power and UPS power conditions
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Building Wiring Fault Indicator
    This LED informs users of potentially dangerous wiring problems in the wall circuit.
  • Cold-start capable
    Provides temporary battery power when the utility power is out.

Back-UPS Features & Benefits

Manageability

LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions

Safety

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Marketing features

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Availability

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Protection

Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .

Product Distribution

United States

Technical Specifications

Output

Max Configurable Power (Watts)
360 Watts / 650VA
Output Frequency (sync to mains)
50/60 Hz +/- 1 Hz Unsynchronised
Topology
Standby
Waveform type
Stepped approximation to a sinewave
Transfer Time
6 ms typical : 10 ms maximum

Input

Input frequency
50/60 Hz +/- 5 Hz Auto-sensing
Input voltage range for main operations
88 - 143V

Batteries & Runtime

Battery Charge Power (Watts)
8.0kWatts

Communications & Management

Interface Port(s)
USB
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

Surge energy rating
490Joules

Physical

Maximum Height
5.47inches (139MM, 13.9CM)
Maximum Width
4.13inches (105MM, 10.5CM)
Maximum Depth
10.79inches (274MM, 27.4CM)
Net Weight
6.83lbs. (3.1KG)
Shipping weight
7.94lbs. (3.6KG)
Shipping Height
8.7inches (221MM, 22.1CM)
Shipping Width
5.67inches (144MM, 14.4CM)
Shipping Depth
13.5inches (343MM, 34.3CM)
Master Carton Dimensions (Length x Width x Height)
14 x 12 x 10inches (356 x 305 x 254MM)
Master Carton Units
2.0
Master Carton Weight
16.98lbs. (7.7)
Pallet Dimensions
47.87 x 40.12 x 87.4inches
# of Layers per Pallet
11.0
Pallet Weight
1567.48lbs.

Environmental

Operating Temperature
32 - 104 °F (0 - 40 °C)
Operating Relative Humidity
0 - 90 %
Operating Elevation
0 - 6666ft (0 - 2031.8meters)
Storage Temperature
-15 - 45 °C
Storage Relative Humidity
0 - 95 (Non-condensing) %
Storage Elevation
0 - 10000ft (0 - 3048meters)

Conformance

Approvals
California Energy Commission (CEC), CSA C22.2 No 107.3, cTUVus, ENERGY STAR V2.0 (USA), FCC part 15 class B, UL 1778
Equipment protection policy
Lifetime : $75000
Standard warranty
3 years repair or replace (excluding battery) and 1 year for battery

Options

Services