Our Brands

Personal SurgeArrest 5 Outlet BS1363 230V

Personal SurgeArrest 5 Outlet BS1363 230V Front Left
Personal SurgeArrest 5 Outlet BS1363 230V Front Left
Personal SurgeArrest 5 Outlet BS1363 230V Front Left
Personal SurgeArrest 5 Outlet BS1363 230V Front Left
Personal SurgeArrest 5 Outlet BS1363 230V Front Straight
Personal SurgeArrest 5 Outlet BS1363 230V Front Left
Personal SurgeArrest 5 Outlet BS1363 230V Front Left
Personal SurgeArrest 5 Outlet BS1363 230V Front Straight
  • Basic Protection Against Power Surges for Computers and Electronics

  • Includes: User manual

View Product Overview

PER5-UK Features

Key Features

Nominal Input Voltage
230V
Input Connections
BS1363A British
Personal SurgeArrest 5 Outlet BS1363 230V
Basic Protection Against Power Surges for Computers and Electronics
Includes: User manual
  • Catastrophic Event Protection
    SurgeArrest components such as MOVs and Thermal fuse ensure instantaneous reaction to lightning strikes and wiring faults. If the surge components are damaged due to power spike or over voltage, excess power cannot reach your equipment. Unlike the APC SurgeArrest products, most surge suppressors continue to let power through even after circuits have been damaged, leaving your equipment exposed to other damaging surges.
  • Lightning and Surge Protection
    When measured via ANSI/IEEE 587 Category ''A" and "B" tests, the suppression performance of the APC Smart-UPS is superior to virtually all separate surge suppressors.
  • Receptacle Shock Safety Shutters
    Shutters protect users from accidental contact with unused outlets.
  • Status Indicator LED's
    Dual Status Indicator - Alerts you to the unit's power status. Green indicates it's ready for use. The Red indicator signals the unit's shutdown to save your automobile battery from draining.

SurgeArrest Essential Features & Benefits

Marketing features

Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Data-line Protection
Protection of data lines (Ethernet, Coaxial and Phone lines) ensures complete protection of your equipment from surges. It is very important to protect your equipment from “back door” electric surges traveling through data lines, as they can be as damaging to your equipment as surges traveling over power lines.

Safety

Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.
Catastrophic Event Protection
SurgeArrest components such as MOVs and Thermal fuse ensure instantaneous reaction to lightning strikes and wiring faults. If the surge components are damaged due to power spike or over voltage, excess power cannot reach your equipment. Unlike the APC SurgeArrest products, most surge suppressors continue to let power through even after circuits have been damaged, leaving your equipment exposed to other damaging surges.
Fail Safe Mode
Most other surge suppressors continue to let power through even after their circuits have been damaged, leaving your equipment exposed to future surges. APC's SurgeArrest fail safe, which means that once the circuit of an APC SurgeArrest has been compromised the unit disconnects equipment from the power supply ensuring that no damaging surges reach your equipment.
Protection working indicator
SurgeArrest will warn you if its circuitry has been damaged by heavy strike or power line surge and it is unable to provide 100% protection. If still under warranty, APC will then replace your damaged SurgeArrest free of charge.

Protection

IEEE let-through ratings and regulatory agency compliance
APC surge protectors undergo stringent testing by IEEE, and are awarded "let-through ratings", which indicate the maximum voltage level that can possibly reach your equipment after a surge or voltage spike has passed through an electric surge protector. Lower IEEE let-through ratings indicate better protection and performance. The APC Essential SurgeArrest series offers optimal performance with a let-through rating of less than 330V to 500V for North American products, and a rating of less than 15% for products sold worldwide. All APC products comply with local agency safety requirements, including UL in North America and CE/Kema/Gost/C-tick/A-Tick/Telepermit in their respective regions.
Lightning and Surge Protection
To prevent damage to your equipment from electric power surges and spikes.
Noise Filtering
Attenuates EMI/RFI line noise that can cause data errors and keyboard lockups, ensuring better performance of protected equipment.

Product Distribution

United Arab Emirates, Antigua and Barbuda, Anguilla, Bahrain, Botswana, Cyprus, Eritrea, United Kingdom, Ghana, Gambia, Hong Kong, Ireland, Iraq, Jordan, Kenya, Kuwait, Myanmar, Malta, Malawi, Malaysia, Nigeria, Netherlands, Oman, Singapore, Sierra Leone, Tanzania, Zambia

Technical Specifications

Output

Number of Outlets
5.0
Receptacle Style
BS 1363 United Kingdom

Input

Input frequency
50/60 Hz
Number of Power Cords
1
Maximum Line Current
10A

Surge Protection and Filtering

eP Joule Rating
315
Peak Current Common Mode
11kAmps
Peak Current Normal Mode
6.5kAmps

Physical

Maximum Height
46MM, 4.58CM
Maximum Width
114MM, 11.44CM
Maximum Depth
286MM, 28.58CM
Net Weight
0.86KG
Shipping weight
0.92KG
Shipping Height
51MM, 5.08CM
Shipping Width
173MM, 17.28CM
Shipping Depth
318MM, 31.76CM
Color
Grey
Master Carton Units
12.0
SCC Codes
20731304016445

Environmental

Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0 - 3048meters
Storage Temperature
-15 - 45 °C
Storage Elevation
0 - 15240meters

Conformance

Approvals
CE
Equipment protection policy
Lifetime : 20000 GBP
Standard warranty
Limited Lifetime (European Union countries only), 3 years (all other countries)

Options

Services