NetBotz Rack Monitor 250

Share:

NetBotz Rack Monitor 250

NBRK0250

Description: Cost-effective and flexible environmental monitoring for all IT environments, from small edge networks to large data centers

Includes : Country-specific detachable power cord , Installation guide , Rack Mounting brackets , Temperature/Humidity Sensor

NetBotz Rack Monitor 250

Call for More Information
+254 703 069000
Includes: Country-specific detachable power cord , Installation guide , Rack Mounting brackets , Temperature/Humidity Sensor

Related Products, Accessories & Services

View all accessories and replacement batteries for this product

NBRK0250 Features

NetBotz Rack Monitor 250

  • Customizable Output Relays
    Control output from external devices via output relay(s).
  • Native wireless sensor support
    Manage up to 47 NetBotz wireless temperature and temp/humidity sensors from a single NetBotz

NetBotz 200 Features & Benefits

  • Browser Accessible
    View the user interface with a browser. Provides quick access from anywhere on a secure network.
  • Adjustable threshold
    Customize threshold definitions (multiple thresholds per sensor, scheduling, severity levels) to your requirements.
  • Flexibility and adaptability
    Can be the environmental monitoring solution, or the rack access control solution, or both.
  • Slim form factor
    Can be mounted in a rack alongside other IT gear, or zero –U mounted in the back
  • Fault notification
    Real-time event notification minimizes response times to critical physical infrastructure situations. Enables IT Administrators to reduce mean time to repair, improve efficiency, and maximize uptime.
  • Access monitoring
    Detect access by unauthorized personnel via door switch.
  • Reboot equipment remotely
    Saves dispatching technicians to remote locations.
  • Reduce Cabling
    Features wireless sensors to reduce the clutter and expense of cabling.
  • Environmental monitoring
    Prevent equipment failure from a full range of threatening environmental conditions.
  • Browser Accessible
    View the user interface with a browser. Provides quick access from anywhere on a secure network.
  • Encryption
    Helps ensure effective access control and integrity for SSL browser and SSH sessions.
  • Fault notification
    Real-time event notification minimizes response times to critical physical infrastructure situations. Enables IT Administrators to reduce mean time to repair, improve efficiency, and maximize uptime.
  • Enterprise management system compatible
    Make device information available to your preferred enterprise management system by forwarding SNMP traps (events) across SNMPv1 and SNMPv3 using the PowerNet MIB
  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Easy Integration
    Integrates with APC racks, NetBotz sensors, and Data Center Expert for easy deployment, configuration, and management.
  • Password Security
    User-selectable password with strong password rules and reset password mechanism.
Product Distribution
Product Distribution

Andorra , United Arab Emirates , Afghanistan , Antigua and Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Australia , Aruba , Azerbaijan , Bosnia and Herzegovina , Barbados , Bangladesh , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Bermuda , Brunei , Bolivia , Brazil , Bahamas , Bhutan , Botswana , Belarus , Belize , Canada , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Cook Islands , Chile , Cameroon , China , Colombia , Costa Rica , Serbia and Montenegro , Cuba , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Dominica , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , Fiji , Falkland Islands , France , Gabon , United Kingdom , Grenada , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Guatemala , Guyana , Hong Kong , Honduras , Croatia , Haiti , Hungary , Indonesia , Ireland , Israel , India , Iraq , Iran , Iceland , Italy , Jamaica , Jordan , Japan , Kenya , Cambodia , Saint Kitts And Nevis , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , Saint Lucia , Liechtenstein , Sri Lanka , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Madagascar , Macedonia , Mali , Myanmar , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Malaysia , Mozambique , Namibia , Niger , Nigeria , Nicaragua , Netherlands , Norway , Nepal , New Zealand , Oman , Panama , Peru , Papua New Guinea , Philippines , Pakistan , Poland , Puerto Rico , Portugal , Paraguay , Qatar , Reunion , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Turks And Caicos Islands , Chad , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , TP , Turkey , Trinidad and Tobago , Taiwan , Tanzania , Ukraine , Uganda , United States , Uruguay , Uzbekistan , Saint Vincent And The Grenadines , Venezuela , U.S. Virgin Islands , Vietnam , XF , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Input

  • Number of Power Cords
    1
  • Input Power
    2400.0Watts

Physical

  • Maximum Height
    43mm , 4.3CM
  • Maximum Width
    432mm , 43.2CM
  • Maximum Depth
    43mm , 4.3CM
  • Rack Height
    1U
  • Net Weight
    1.09KG
  • Shipping weight
    2.39KG
  • Shipping Height
    64mm , 6.4CM
  • Shipping Width
    457mm , 45.7CM
  • Shipping Depth
    222mm , 22.2CM

Environmental

  • Operating Temperature
    0 - 45 °C
  • Operating Relative Humidity
    0 - 95 %
  • Operating Elevation
    0-3000meters
  • Storage Temperature
    -15 - 65 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0-15000meters

Conformance

  • Standard warranty
    2 years repair or replace

Sustainable Offer Status

  • Battery Directive
    Compliant

General

  • Type of Camera Pods Supported
    Rack Sensor Pod 150
  • Type of External Sensors Supported
    Door Contact, Dry Contact, Humidity, Smoke, Fluid Spot Leak, Temperature, Vibration
  • Number of Additional Camera Pods
    6.0
  • Number of Additional Sensor Pods
    6.0
  • Sensor Humidity Range
    ±3% RH from 11% to 89% RH %
  • External Sensor Ports
    0 Integrated, 0 Networked, 0 USB
  • Sensor Temperature Range
    15°C to 50°C (32°F to 122°F) +/- 1°C (1.8°F) °F
Manuals and Warranties
Title
Size
Updated On
PDF

Size

640KB

Updated On

2018-06-20

Includes physical description, inventory list, installation procedures, network configuration procedures, specifications, warranty details.
PDF

Size

349KB

Updated On

2018-06-18

Release notes for the NetBotz Rack Monitor 250 firmware version 6.5.6
PDF

Size

419KB

Updated On

2018-06-15

Configuration; Customization
PDF

Size

337KB

Updated On

2018-06-12

Rack access handles for use with the NetBotz Rack Monitor 250 only
PDF

Size

1293KB

Updated On

2018-06-11

Provides complete details on how to use the NetBotz Rack Monitor 250 software interface
PDF

Size

456KB

Updated On

2018-05-11

Security Configuration
Brochure
Title
Size
Updated On
PDF

Size

8248KB

Updated On

2018-06-14

Customer Facing NetBotz 250 Inforgraphic
PDF

Size

615KB

Updated On

2018-06-12

Product brochure detailing the NetBotz 250 benefits and options.
PDF

Size

6001KB

Updated On

2018-06-11

eGuide focused on Environmental Monitoring
Agency Approvals
Title
Size
Updated On
PDF

Size

362KB

Updated On

2018-06-18

CCC Exemption
PDF

Size

218KB

Updated On

2018-06-01

Regulatory requirement in the EU
Title
Size
Updated On

Firmware Upgrades

Firmware Upgrades
Part Number
Updated On

Part Number

SFNBY646

Updated On

2017-03-30
Release notes for the NetBotz Rack Monitor 250 firmware version 6.5.6

Part Number

SFNBY375

Updated On

2015-10-08

Part Number

SFNBY645

Updated On

2016-10-03

Part Number

SFNBY356

Updated On

2009-11-30

Part Number

SFNBY650

Updated On

2017-11-15

Category

Sub-Category


NetBotz Room Monitor 455 (with 120/240V PoE Injector)

Features integrated camera and sensors (temperature, humdity, airflow, dewpoint, camera motion). Supports 3 additional external cameras pods, 2 sensor pods and up to 16 Universal Sensors.

NetBotz Wireless USB Coordinator & Router

Wireless USB receiver and router. When plugged into compatible appliances, it enables a wireless network to be created. When used with the included power supply, it extends the range of the wireless network.

NetBotz Smoke Sensor - 10 ft.

Universal Sensor that detects smoke in IT spaces. This sensor supplements the existing life safety system already in place.

NetBotz Room Sensor Pod 155

Sensor pod optimized for wall mounting that supports 4 Universal Sensors.

NetBotz Room Monitor 355 (without PoE Injector)

Features integrated camera and sensors (temperature, humdity, airflow, dewpoint, camera motion). Supports up to 4 Universal Sensors.

NetBotz Vibration Sensor - 12 ft.

Universal Sensor that detects vibration in racks that may indicate movement of IT assets.


Show results per page