APC Back-UPS 1000VA, 120V, AVR, LAM

APC Back-UPS 1000VA, 120V, AVR, LAM Front Left
APC Back-UPS 1000VA, 120V, AVR, LAM Front Left
APC Back-UPS 1000VA, 120V, AVR, LAM Front Left
APC Back-UPS 1000VA, 120V, AVR, LAM Back
RoHS
  • Battery Backup & Surge Protector for Electronics and Computers

  • Includes: Installation guide, User Manual

View Product Overview

BX1000L-LM Features

APC Back-UPS 1000VA, 120V, AVR, LAM
Battery Backup & Surge Protector for Electronics and Computers
Includes: Installation guide, User Manual
  • Audible alarms
    Provides notification of changing utility power and UPS power conditions
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Automatic Voltage Regulation (AVR)
    Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
  • Boost and Trim Automatic Voltage Regulation (AVR)
    Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
  • LED Indicators
    Provide easy-to-read status of the unit and utility power conditions.
  • Overload Indicator
    Indicator illuminates when connected equipment draws more power than unit’s capacity. To remedy the condition, unplug less vital equipment.
  • Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Back-UPS Features & Benefits

Marketing Features

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Safety

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Manageability

Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status display
Quickly understand unit and power status with visual indicators.

Availability

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Protection

Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

Product Distribution

Antigua and Barbuda, Anguilla, Netherlands Antilles, Argentina, Aruba, Bermuda, Bolivia, Bahamas, Belize, Chile, Colombia, Costa Rica, Cuba, Dominica, Dominican Republic, Ecuador, Falkland Islands, Grenada, Guatemala, Guyana, Honduras, Haiti, Saint Kitts And Nevis, Cayman Islands, Saint Lucia, Mexico, Nicaragua, Panama, Peru, Puerto Rico, Paraguay, El Salvador, Trinidad and Tobago, Uruguay, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands

Output

Output power capacity
600Watts / 1.0kVA
Max Configurable Power (Watts)
600Watts / 1.0kVA
Nominal Output Voltage
120V
Output Frequency (sync to mains)
60Hz +/- 3 Hz
Waveform type
Stepped approximation to a sinewave
Output Connections
(6) NEMA 5-15R (Battery Backup)
Transfer Time
6ms typical : 10ms maximum

Input

Nominal Input Voltage
110V, 120V
Input frequency
60 Hz +/- 5 Hz
Input Connections
NEMA 5-15P
Cord Length
1.22meters
Input voltage range for main operations
80 - 138 (Line to Neutral)V
Number of Power Cords
1
Maximum Input Current
8.0A
Input Power Factor at Full Load
0.6

Batteries & Runtime

Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Included Battery Modules
1
Typical recharge time
6hour(s)
Expected Battery Life (years)
2 - 4
Battery Volt-Amp-Hour Capacity
114

Communications & Management

Control panel
LED Status display with On Line : On Battery
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

Surge energy rating
160Joules

Physical

Maximum Height
182MM, 18.2CM
Maximum Width
130MM, 13.0CM
Maximum Depth
320MM, 32.0CM
Net Weight
8.2KG
Shipping weight
9.0KG
Shipping Height
197MM, 19.7CM
Shipping Width
285MM, 28.5CM
Shipping Depth
395MM, 39.5CM

Environmental

Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0-600meters
Storage Temperature
-20 - 50 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0-4500meters
Audible noise at 1 meter from surface of unit
40.0dBA

Conformance

Approvals
NOM, TUV
Standard warranty
2 years repair or replace

Sustainable Offer Status

RoHS
Compliant
REACH
REACH: Contains No SVHCs