Uniflair Chilled Water Unit, EC fans, Downflow, 140-250 kW

Share:

Uniflair Chilled Water Unit, EC fans, Downflow, 140-250 kW

HXCV

Uniflair Chilled Water Unit, EC fans, Downflow, 140-250 kW

For the specifications, please refer to the product brochure and catalogue

Call for More Information
0800 2799254

HXCV 

Uniflair Chilled Water Unit, EC fans, Downflow, 140-250 kW

  • Air filters
    High efficiency EU4 or EU5 filters. Surface maximization for low air pressure drops.
  • Coil module
    For installation above the raised floor, the coil module internal aeraulic layout optimizes airflow management and maximizes fan efficiency.
  • Electronically Commutated Fans
    Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
  • High temperature operation
    High Temperature version units can operate with water at 20 -30°C up to 32°C.
  • Optimized airflow management
    Room units communicate with external chillers. Chilled water temperature varies dynamically to minimize compressor consumption and maximize the use of free-cooling.
  • Power supply
    Single and double power supply. Ultracapacitor option.
  • Underfloor fans
    The fan module can be installed underneath the floor for more heat exchange surface and less internal air-side pressure drop. This ensures less power consumption and more cooling capacity in the same footprint.

Uniflair Med/Large Room Cooling Features & Benefits

  • Multi-functional Microprocessor Controller
    Allows the units to restart after a power failure without intervention; Allows for room level redundancy with up to ten units operating in a group; User friendly navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System protocols.
  • Active response control
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
  • Redundant Components
    Single points of failure in the system have redundant components to maintain availability and reliability.
  • Direct drive motors
    Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
  • Electronic expansion valve
    Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
  • Local area network
    Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
  • Network interface
    Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
  • Automatic Floor Pressurization System
    Ensures stable airflow pressurization under floor regardless of changes made above the floor
  • Building Management Systems
    Units are designed to work with the most common BMS systems including BACnet and Modbus.
  • Service monitoring
    All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Operational Service
    Allows critical components to be maintained/replaced while the system is in operation.
  • Optimized management
    Connection between the Computer Room Air Conditioners and the chillers guarantees energy efficiency, based on real instantaneous load conditions (optional)
  • Electronically Commutated Fans
    Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
  • Modular strategy
    Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expenditure and provides deferred investment throughout the life of the facility.
Product Distribution
Product Distribution

United Arab Emirates , Austria , Australia , Belgium , Bulgaria , Switzerland , Chile , Serbia and Montenegro , Czechia , Germany , Denmark , Algeria , Estonia , Egypt , Spain , Finland , France , United Kingdom , Greece , Croatia , Hungary , Indonesia , Ireland , Israel , India , Italy , South Korea , Kazakhstan , Lithuania , Latvia , Morocco , North Macedonia , Malaysia , Nigeria , Netherlands , Norway , New Zealand , Philippines , Portugal , Romania , Saudi Arabia , Sweden , Singapore , Slovenia , Thailand , Tunisia , Turkey , Taiwan , Ukraine , Vietnam , South Africa

Print Technical Specification

Input

  • Input frequency
    50 Hz

Communications & Management

  • Control panel
    7" touch screen display

General

  • Air Discharge Patterns
    Downflow
  • Intake Air
    Front return, Top return
Title
Size