Uniflair InRow RC, 300mm, Chilled Water, 100-240V, 50/60 Hz - ST

Uniflair InRow RC, 300mm, Chilled Water, 100-240V, 50/60 Hz - ST

ACRC301S

Uniflair InRow RC, 300mm, Chilled Water, 100-240V, 50/60 Hz - ST

null

Call for More Information
800-800-4272
Includes: Installation guide,Operations and maintenance manual

ACRC301S 

Uniflair InRow RC, 300mm, Chilled Water, 100-240V, 50/60 Hz - ST

  • Active Airflow Control
    Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
  • Hot swappable fans
    Allows system to remain operational if a fan replacement is required.
  • Leak detection
    Notifies user in the event of a water leak within the coiling unit.
  • Top and bottom chilled water connections
    Provide flexibility in installation based on the constraints of a given area.
  • Washable filters
    Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

Uniflair Chilled Water InRow Cooling Features & Benefits

  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Dual A-B power inputs
    Draws power from the UPS for power protection with dual feeds for redundancy.
  • Top and bottom chilled water connections
    Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
  • Rack inlet control
    Rack inlet control guarantees inlet temperature to IT equipment.
  • Scalable densities
    Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Modular design
    Modular design provides scalable solutions to add cooling as demand increases.
  • Casters
    Provides flexibility to move the unit to wherever cooling is required.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Real-Time capacity monitoring
    Real-time display of current and available cooling.
  • Microprocessor controller
    Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
  • Building management system integration
    Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Product Distribution
Product Distribution

United Arab Emirates , Albania , Armenia , Angola , Argentina , Austria , Australia , Azerbaijan , Bosnia & Herzegovina , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Brazil , Botswana , Belarus , Canada , Congo - Kinshasa , Switzerland , Côte d’Ivoire , Chile , Cameroon , China , Colombia , Costa Rica , Serbia and Montenegro , Cyprus , Czechia , Germany , Djibouti , Denmark , Algeria , Estonia , Egypt , Eritrea , Spain , Ethiopia , Finland , France , Gabon , United Kingdom , Georgia , French Guiana , Ghana , Gambia , Guadeloupe , Greece , Hong Kong SAR China , Croatia , Hungary , Ireland , Israel , India , Iraq , Iceland , Italy , Jordan , Japan , Kenya , South Korea , Kuwait , Kazakhstan , Lebanon , Liberia , Lithuania , Luxembourg , Latvia , Morocco , Madagascar , North Macedonia , Mali , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Mozambique , Namibia , Nigeria , Netherlands , Norway , Oman , Philippines , Pakistan , Poland , Portugal , Qatar , Réunion , Romania , Rwanda , Saudi Arabia , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , Turks & Caicos Islands , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , Turkey , Taiwan , Tanzania , Ukraine , Uganda , United States , Uzbekistan , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Input

  • Input frequency
    50/60 Hz
  • Input Connections
    IEC 60309 16 A 2P + E, NEMA L5-20P
  • Number of Power Cords
    2
  • Power Feeds
    2.0
  • Input Power
    800 Watts

Communications & Management

  • Control panel
    Multifunction LCD status and control console

Physical

  • Maximum Height
    1991MM , 199.1CM
  • Maximum Width
    300MM , 30.0CM
  • Maximum Depth
    1095MM , 109.5CM
  • Rack Height
    42U
  • Net Weight
    184.0KG
  • Shipping weight
    192.0KG
  • Shipping Height
    2118MM , 211.8CM
  • Shipping Width
    1137MM , 113.7CM
  • Shipping Depth
    746MM , 74.6CM
  • Color
    Black

Conformance

  • Approvals
    C-Tick, CE, EN 55022 class A, EN 55024, EN 60950, GOST, IEC 60950, IEC 61000-3-2, IEC 61000-3-3, MEA, VDE
  • Standard warranty
    1 year (parts only)

Sustainable Offer Status

  • Other Environmental Compliance
    China RoHS

General

  • Air Discharge Patterns
    Horizontal
  • Air Flow
    1510.2lps
  • Intake Air
    Rear return
  • Minimum Water Inlet Temperature
    7.2 °C
Manuals and Warranties
Title
Size
Updated On
PDF

Size

580KB

Updated On

2024-02-29

Installation; General Specifications
PDF

Size

737KB

Updated On

2024-01-03

PDF

Size

1055KB

Updated On

2023-10-04

PDF

Size

129KB

Updated On

2023-10-04

Manangement information base document.
PDF

Size

3144KB

Updated On

2023-09-29

InRow RC Gen 2 300 mm Upper Piping Kit (ACRC301S) Installation
PDF

Size

1769KB

Updated On

2023-09-29

PDF

Size

1475KB

Updated On

2023-09-29

InRow RC Gen 2 300mm Online Users Guide
PDF

Size

116KB

Updated On

2023-09-29

InRow RC 300mm Release Notes for v6.2.2
PDF

Size

6639KB

Updated On

2023-09-29

Installation instructions for the InRow RC ACRC301S and ACRC301H air conditioners.
PDF

Size

91KB

Updated On

2023-09-29

Declaration of Conformity
PDF

Size

173KB

Updated On

2023-07-26

InRow RC Gen 2 300mm Modbus Register Map
Catalogs
Title
Size
Updated On
PDF

Size

724KB

Updated On

2023-10-04

Brochure outlining Uniflair Chilled Water InRow Cooling. This brochure contains detailed product overview as well as SKU specific information technical data
Design/Configuration
Title
Size
Updated On
PDF

Size

4172KB

Updated On

2023-09-29

Technical specifications for the ACRC600/P series of cooling units and the ACRC301S and ACRC301H cooling units
Agency Approvals
Title
Size
Updated On
PDF

Size

2762KB

Updated On

2024-02-22

CMIM Declararation of Conformity for InRow Chilled Water Air Conditioners models ACRC301S and ACRC301H.
PDF

Size

301KB

Updated On

2024-02-22

This is EC Declaration of Conformity for InRow Chilled Water 300mm Products
Bid Spec
Title
Size
Updated On
PDF

Size

356KB

Updated On

2023-10-04

Guide Specification for the InRow Chilled Water product line
Title
Size
Updated On
Cooling Solutions, InRow Chilled Water, Package
Cooling Solutions, InRow Chilled Water, Accessories
CAD Source File
1760KB
2023-10-04

Cooling Solutions, Close Coupled Air Conditioners, InRow Chilled Water
CAD Source File
1088KB
2023-10-04

BIM Models, Cooling Solutions, InRow RC

Category

Sub-Category


Custom quoted service contract

An APC factory trained technician will arrive on site to diagnose or repair your APC equipment

ACRC301S LEVEL 1 SPARE PARTS KIT

Close-coupled, chilled water cooling for medium to large data centers

ACRC301S LEVEL 2 SPARE PARTS KIT

10-100 kVA high performance, compact, pre- engineered 3 phase UPS for light and heavy industrial applications.

ACRC301S LEVEL 3 SPARE PARTS KIT

Close-coupled, chilled water cooling for medium to large data centers

Start-Up Service 5X8 for InfraStruXure® InRow RC

A set of service options designed to deliver the vital resources, expertise, and tools needed to quickly and efficiently implement your APC by Schneider Electric solution

Start-Up Service 7x24 for InfraStruXure® InRow RC

A set of service options designed to deliver the vital resources, expertise, and tools needed to quickly and efficiently implement your APC by Schneider Electric solution

Advanced Operator Training for In-Row Cooling

Increase your knowledge and confidence to operate and manage your data center physical infrastructure learning from our industry proven professionals


Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product