APC High-Density Cooling Valve Box Assembly

APC High-Density Cooling Valve Box Assembly Front Left
APC High-Density Cooling Valve Box Assembly Front Left
APC High-Density Cooling Valve Box Assembly Front Left
APC High-Density Cooling Valve Box Assembly Front Left
APC High-Density Cooling Valve Box Assembly Front Straight
APC High-Density Cooling Valve Box Assembly Detailed
APC High-Density Cooling Valve Box Assembly Front Left
APC High-Density Cooling Valve Box Assembly Front Left
APC High-Density Cooling Valve Box Assembly Front Straight
APC High-Density Cooling Valve Box Assembly Detailed
  • Self-contained rack enclosures with up to 18kW cooling capacity for high-density server deployments in space-constrained and/or uncontrolled environments.

  • Includes: Installation Guide

View Product Overview

ARACVB1 Features

APC High-Density Cooling Valve Box Assembly
Self-contained rack enclosures with up to 18kW cooling capacity for high-density server deployments in space-constrained and/or uncontrolled environments.
Includes: Installation Guide

High-Density Cooling Enclosures Features & Benefits

Manageability

Warning indicator light
Provides highly visible, local notification of problematic events.
Remote management
Remote monitoring of key alarm conditions such as fan failure and leak detection via SNMP, telnet, and web browser is possible with optional Remote Monitoring Unit, specifically designed for the High-Density Cooling Enclosure.

Adaptability

Base cable access
Allows power and data cable to be routed into the enclosure from under a raised floor.
Top cable access
Allows power and data cable to be routed into the enclosure from overhead.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Adjustable rear vertical mounting rails
Accommodate various mounting depths from IT equipment manufacturers.

Availability

Hot swappable cooling coil
Allows system to remain operational if a cooling coil replacement is required.
Hot swappable fans
Allows system to remain operational if a fan replacement is required.
Fail-safe control system
Ensures sufficient cooling is still provided by enabling maximum fan speed in the unlikely event of a control system failure.
Access independent airflow
Fans continue to provide adequate airflow even when doors are opened.
Leak detection
Notifies user in the event of a water leak within the coiling unit.
Horizontal airflow design
Ensures uniform delivery of cool air to installed IT equipment.
Temperature regulation
Ensures installed IT equipment always maintains acceptable inlet air temperatures.
N+1 redundant fans
Provide higher availability to installed equipment with six fans supporting installed equipment in an N+1 configuration.

Agility

Ships fully assembled
Allows for fast deployment.

Protection

Isolated cooling circuit
A separate, isolated section which houses all cooling components minimizes the risk of water contacting installed IT equipment in the unlikely event of a leak.
Smart card door access
Provides easy and secure access to system.
Insulated double wall construction
Prevents condensation from forming on the outside of the enclosure and reduces noise emission.
Sealed enclosure
Prevents infiltration of dust and moisture while preventing dissipation of heat into installation environment.
Dew point monitoring
Prevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature.

Product Distribution

Andorra, United Arab Emirates, Albania, Armenia, Angola, Austria, Azerbaijan, Bosnia and Herzegovina, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, Botswana, Belarus, Canada, The Democratic Republic Of Congo, Central African Republic, Congo, Switzerland, Côte d'Ivoire, Cameroon, Serbia and Montenegro, Cyprus, Czech Republic, Germany, Djibouti, Denmark, Algeria, Estonia, Egypt, Western Sahara, Eritrea, Spain, Ethiopia, Finland, France, Gabon, United Kingdom, Georgia, French Guiana, Ghana, Gibraltar, Gambia, Guinea, Guadeloupe, Equatorial Guinea, Greece, Croatia, Hungary, Ireland, Israel, Iraq, Iran, Iceland, Italy, Jordan, Kenya, Cambodia, Kuwait, Kazakhstan, Lebanon, Liechtenstein, Liberia, Lesotho, Lithuania, Luxembourg, Latvia, Morocco, Moldova, Madagascar, Macedonia, Mali, Mongolia, Martinique, Mauritania, Malta, Mauritius, Malawi, Mozambique, Namibia, Niger, Nigeria, Netherlands, Norway, Oman, Pakistan, Poland, Portugal, Reunion, Romania, Russia, Rwanda, Saudi Arabia, Sudan, Sweden, Slovenia, Slovakia, Sierra Leone, Senegal, Somalia, Suriname, Chad, Togo, Tajikistan, Turkmenistan, Turkey, Tanzania, Ukraine, Uganda, United States, Uzbekistan, XF, Yemen, Mayotte, South Africa, Zambia, Zimbabwe

Input

Number of Power Cords
1

Physical

Maximum Height
279MM, 27.94CM
Maximum Width
318MM, 31.75CM
Maximum Depth
660MM, 66.04CM
Net Weight
10.45KG
Shipping weight
12.27KG
Shipping Height
368MM, 36.83CM
Shipping Width
375MM, 37.47CM
Shipping Depth
730MM, 73.03CM

Conformance

Approvals
CE

Options