Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain

Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain Front Left
Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain Front Left
Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain Front Left
Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain Front Straight
Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain Back
Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain Front Left
Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain Front Straight
Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain Back
  • Close-coupled, chilled water cooling for medium to large data centers

  • Includes: Installation guide, Operations and maintenance manual, User manual

View Product Overview

ERC612CD0CGE Features

Key Features

Rack Height
48U
Row CW 600mm 48U 1200mm Deep,380V,Dual feed, Gravity drain
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation guide, Operations and maintenance manual, User manual
  • Capacity Control
    Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.
  • Casters
    Provides flexibility to move the unit to wherever cooling is required.
  • Dual power inputs
    (Optional) Dual power supplies for incoming power redundancy
  • Electronically Commutated Fans
    Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
  • Scalable Design
    Modular design provides scalable solutions to add cooling as demand increases.
  • Top and bottom chilled water connections
    Provide flexibilty in installation based on the constraints of a given area.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Washable filters
    Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

Easy Cooling Row CW Features & Benefits

Total cost of Ownership

Capacity Control
Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

Adaptability

Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Redundant fans
In the event of fan failure, redundant fans will provide increased airflow.
Dual power inputs
(Optional) Dual power supplies for incoming power redundancy
Flexibility
Support for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment
Top and bottom chilled water connections
Provide flexibilty in installation based on the constraints of a given area.
Active Airflow Control
Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
Casters
Provides flexibility to move the unit to wherever cooling is required.

Serviceability

Microprocessor controller
The system is controlled by a microprocessor, with an 80-character LCD backlit alphanumeric display, that provides communication and alarm indication.
Washable filters
Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Product Distribution

Belgium, Bulgaria, Brazil, Switzerland, Chile, China, Colombia, Costa Rica, Serbia and Montenegro, Czech Republic, Germany, Denmark, Algeria, Estonia, Egypt, Spain, Finland, France, United Kingdom, Greece, Hong Kong, Croatia, Hungary, Indonesia, Ireland, Israel, India, Italy, Japan, South Korea, Kazakhstan, Lithuania, Latvia, Morocco, Macedonia, Mexico, Malaysia, Nigeria, Netherlands, Norway, New Zealand, Peru, Philippines, Poland, Portugal, Romania, Russia, Saudi Arabia, Sweden, Singapore, Slovenia, Slovakia, Thailand, Tunisia, Turkey, Taiwan, Ukraine, Vietnam, South Africa

Technical Specifications

Input

Input frequency
50 Hz
Power Feeds
2.0

Communications & Management

Control panel
7" touch screen display

Physical

Maximum Height
2200MM, 220.0CM
Maximum Width
600MM, 60.0CM
Maximum Depth
1200MM, 120.0CM
Net Weight
235.0KG
Shipping weight
265.0KG
Shipping Height
2390MM, 239.0CM
Shipping Width
720MM, 72.0CM
Shipping Depth
1320MM, 132.0CM
Color
Black

Conformance

Standard warranty
1 year on-site repair or replace with factory authorized Start-Up