MGE Galaxy 300i 30kVA 400V 3:3 with Transformer, Start-up 5x8

G3HTI30KHLS

Description: Effective three phase power protection against downtime and data loss for mission critical applications. Ruggedized version including dust filter,conformance coated boards, integrated transformer, and IP 21 Kit protection for harsh environments. UPS supplied without internal batteries. Requires purchase of external battery cabinet. Please click here for additional runtime information.

Includes : CD with software , Installation guide , Network Management Card , Start-Up Service , User Manual

MGE Galaxy 300i 30kVA 400V 3:3 with Transformer, Start-up 5x8

Effective three phase power protection against downtime and data loss for mission critical applications. Ruggedized version including dust filter,conformance coated boards, integrated transformer, and IP 21 Kit protection for harsh environments. UPS supplied without internal batteries. Requires purchase of external battery cabinet. Please click here for additional runtime information.

Includes: CD with software , Installation guide , Network Management Card , Start-Up Service , User Manual

G3HTI30KHLS Features

MGE Galaxy 300i 30kVA 400V 3:3 with Transformer, Start-up 5x8

  • Integrated transformer
    Can be configured on-site as either a bypass or output transformer for full galvanic isolation and increased load protection.

Galaxy 300 Features & Benefits

  • Integrated network management
    Provides complete remote monitoring and control of the UPS. Enables you to monitor remote UPS's from a web browser or industry standard Network Management System.
  • Easy to install
    Innovative design allows for fast, easy installation by almost anybody.
  • Cost of acquisition
    Designed to provide an optimized price/performance ratio, a number of exceptional features have been carefully selected to optimize both performance and cost benefits.
  • Front-access servicing
    Simplifies installation and UPS maintenance while minimizing space requirements.
  • 5x8 Start-up service included
    Required for full coverage of factory warranty
  • Dual feed input
    Allows installation of two independent power sources with the option of hot stand-by configuration to provide redundancy for mission critical applications.
  • Parallel-redundant capable
    Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
  • Double conversion on-line topology
    Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
  • Wide input voltage range
    Designed for harsh electrical environments to save battery life.
  • RoHS
    Certifies that electronic devices don't contain hazardous metals and flame retardants
  • EU CoC for UPS
    Ensures that UPSs sold in the EU are highly efficient
Product Distribution
Product Distribution

Andorra , United Arab Emirates , Afghanistan , Albania , Armenia , Angola , Austria , Australia , Azerbaijan , Bosnia and Herzegovina , Bangladesh , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Brunei , Bhutan , Botswana , Belarus , The Democratic Republic Of Congo , Central African Republic , Congo , Côte d'Ivoire , Cook Islands , Cameroon , China , Serbia and Montenegro , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Algeria , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , Fiji , France , Gabon , United Kingdom , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Hong Kong , Croatia , Hungary , Indonesia , Ireland , Israel , India , Iraq , Iran , Iceland , Italy , Jordan , Kenya , Cambodia , South Korea , Kuwait , Kazakhstan , Lebanon , Liechtenstein , Sri Lanka , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Madagascar , Macedonia , Mali , Myanmar , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Malaysia , Mozambique , Namibia , Niger , Nigeria , Netherlands , Norway , Nepal , New Zealand , Oman , Papua New Guinea , Philippines , Pakistan , Poland , Portugal , Qatar , Reunion , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , Turks And Caicos Islands , Chad , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , TP , Turkey , Taiwan , Tanzania , Ukraine , Uganda , Uzbekistan , Vietnam , XF , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Output

  • Output power capacity
    24.0 KWatts / 30.0 kVA
  • Max Configurable Power (Watts)
    24.0 KWatts / 30.0 kVA
  • Nominal Output Voltage
    400V 3PH
  • Output Voltage Note
    Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
  • Output Voltage Distortion
    Less than 5%
  • Output Frequency (sync to mains)
    50/60 Hz +/- 5%
  • Output Frequency (not synced)
    60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
  • Other Output Voltages
    380, 415
  • Load Crest Factor
    2.5 : 1
  • Topology
    Double Conversion Online
  • Waveform type
    Sine wave
  • Overload Operation
    60 seconds @ 120% and 30 seconds @ 145%
  • Maximum Output Current
    65
  • Output Voltage THD
    < 3% linear load and <5% non-linear load
  • Output Voltage Tolerance
    +/- 2% static and 100% load step

Input

  • Nominal Input Voltage
    400V 3PH
  • Input frequency
    45 - 65 Hz
  • Input Connections
    Hard Wire 5-wire (3PH + N + G)
  • Input voltage range for main operations
    340 - 477V
  • Input voltage adjustable range for mains operation
    323 - 437 (380V), 340 - 460 (400V), 357 - 477 (415V)V
  • Input Total Harmonic Distortion
    Less than 5% for full load
  • Type of Input Protection Required
    gL fuse
  • Other Input Voltages
    380, 415
  • Maximum Input Current
    47.0A
  • Input Power Factor at Full Load
    0.99

Batteries & Runtime

  • Battery type
    No internal battery - uses external battery system
  • Nominal Battery Voltage
    +/-192 V (split battery referenced to neutral)
  • Expected Battery Life (years)
    3 - 5
  • End of Discharge Battery Voltage
    +/-154 V

Communications & Management

  • Control panel
    Multi-function LCD status and control console
  • Emergency Power Off (EPO)
    Yes

Physical

  • Maximum Height
    1300mm , 130.0CM
  • Maximum Width
    500mm , 50.0CM
  • Maximum Depth
    950mm , 95.0CM
  • Net Weight
    200.0KG
  • Shipping weight
    226.0KG
  • Shipping Height
    1440mm , 144.0CM
  • Shipping Width
    800mm , 80.0CM
  • Shipping Depth
    965mm , 96.5CM

Environmental

  • Operating Temperature
    0 - 35 °C
  • Operating Relative Humidity
    0 - 95 %
  • Operating Elevation
    0-9000meters
  • Storage Temperature
    -10 - 60 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0-9000meters
  • Audible noise at 1 meter from surface of unit
    53.6dBA
  • Online thermal dissipation
    1804.0BTU/hr
  • Protection Class
    IP 21

Conformance

  • Approvals
    CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUV, VFI-SS-111
  • Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up
Manuals and Warranties
Title
Size
Updated On
PDF

Size

6078KB

Updated On

2018-06-19

Providing the user with information on operation, maintenance and troubleshooting of the Galaxy 300 and 300i system
PDF

Size

1096KB

Updated On

2018-06-18

Schneider Electric Important Safety Instructions in English, Chinese Simplified, French, German, European Spanish, Italian, Russian, Portuguese Brazilian, Dutch, Japanese and Korean
PDF

Size

7722KB

Updated On

2018-06-15

Providing the certified electrician with information on how to install and connect the Galaxy 300i UPS
PDF

Size

5210KB

Updated On

2018-06-12

Providing information on storage conditions and how to unpack the galaxy 300 and 300i cabinets and remove them from the pallet
Brochure
Title
Size
Updated On
PDF

Size

2465KB

Updated On

2018-06-19

Technical brochure for sales.partners
Design/Configuration
Title
Size
Updated On
PDF

Size

250KB

Updated On

2018-06-19

Battery runtime charts for standard non -modular battery configurations
PDF

Size

8392KB

Updated On

2018-06-11

Providing information on technical data, facility planning, drawings, and options
Agency Approvals
Title
Size
Updated On
PDF

Size

377KB

Updated On

2018-06-15

TUV certificate
PDF

Size

83KB

Updated On

2018-06-15

Certificate of Origin
Title
Size
Updated On
MGE Galaxy 300i,3:3 Version with Isolation XFMR,System One Line Diagram
MGE Galaxy 300i,3:3 Version with Isolation XFMR,Mechanicals
MGE Galaxy 300i,3:1 Version with Isolation XFMR,System One Line Diagram

Firmware Upgrades

Firmware Upgrades
Part Number
Updated On

Firmware Upgrades

PowerNet MIB v4.2.6

Part Number

SFPMIB426

Updated On

2018-01-24

Category

Sub-Category


Refresh-UPS MGE Galaxy 300 30kVA 400V 3:3 with 10min Batt, Start-up 5x8, RMS and 2 Yrs Service Plan

Go from OUTDATED to UPGRADED. It's time to update or renovate your aging 3-phase UPS or cooling system. Extending its lifespan can reduce costs and boost uptime!

External Battery breaker box 60-80KVA

External battery breaker box for use with third party battery configurations. *Actual breaker may vary from image.

Refresh-UPS MGE Galaxy 300 30kVA 400V 3:3 with 25min Batt, Start-up 5x8, RMS and 2 Yrs Service Plan

Go from OUTDATED to UPGRADED. It's time to update or renovate your aging 3-phase UPS or cooling system. Extending its lifespan can reduce costs and boost uptime!

Refresh-UPS MGE Galaxy 300 30kVA 400V 3:1 with 25min Batt, Start-up 5x8, RMS and 2 Yrs Service Plan

Go from OUTDATED to UPGRADED. It's time to update or renovate your aging 3-phase UPS or cooling system. Extending its lifespan can reduce costs and boost uptime!

1 Year On-Site Warranty Extension for (1) Galaxy 300 30 kVA UPS

Comprehensive service packages that allow you to design the coverage you need to operate your solution efficiently, minimize downtime and manage costs.

Refresh-UPS MGE Galaxy 300 30kVA 400V 3:1 with 10min Batt, Start-up 5x8, RMS and 2 Yrs Service Plan

Go from OUTDATED to UPGRADED. It's time to update or renovate your aging 3-phase UPS or cooling system. Extending its lifespan can reduce costs and boost uptime!


Show results per page
Installation Services

UPS Network Management Cards

Related Products, Accessories & Services

View all accessories and replacement batteries for this product