MGE Galaxy 300 60kVA 400V 3:3, 0min Start-up 5x8

Share:

MGE Galaxy 300 60kVA 400V 3:3, 0min Start-up 5x8

G3HT60KHLS

Description: Effective three phase power protection against downtime and data loss for mission critical applications. UPS with long backup charger, supplied without batteries. To be used with external batteries. Please click here for additional runtime information

Includes : CD with software , Dust filter , Installation guide , Network Management Card , Start-Up Service , User Manual

MGE Galaxy 300 60kVA 400V 3:3, 0min Start-up 5x8

Effective three phase power protection against downtime and data loss for mission critical applications. UPS with long backup charger, supplied without batteries. To be used with external batteries. Please click here for additional runtime information

Call for More Information
44553010
Includes: CD with software , Dust filter , Installation guide , Network Management Card , Start-Up Service , User Manual

Galaxy 300 Features & Benefits

  • Dual feed input
    Allows installation of two independent power sources with the option of hot stand-by configuration to provide redundancy for mission critical applications.
  • Parallel-redundant capable
    Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
  • Double conversion on-line topology
    Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
  • Wide input voltage range
    Designed for harsh electrical environments to save battery life.
  • EU CoC for UPS
    Ensures that UPSs sold in the EU are highly efficient
  • RoHS
    Certifies that electronic devices don't contain hazardous metals and flame retardants
  • Front-access servicing
    Simplifies installation and UPS maintenance while minimizing space requirements.
  • 5x8 Start-up service included
    Required for full coverage of factory warranty
  • Easy to install
    Innovative design allows for fast, easy installation by almost anybody.
  • Integrated network management
    Provides complete remote monitoring and control of the UPS. Enables you to monitor remote UPS's from a web browser or industry standard Network Management System.
  • Cost of acquisition
    Designed to provide an optimized price/performance ratio, a number of exceptional features have been carefully selected to optimize both performance and cost benefits.
Product Distribution
Product Distribution

Andorra , United Arab Emirates , Albania , Armenia , Angola , Argentina , Austria , Azerbaijan , Bosnia and Herzegovina , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Brunei , Bolivia , Botswana , Belarus , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Chile , Cameroon , China , Serbia and Montenegro , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Algeria , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , France , Gabon , United Kingdom , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Hong Kong , Croatia , Hungary , Indonesia , Ireland , Israel , Iraq , Iran , Iceland , Italy , Jamaica , Jordan , Kenya , Cambodia , South Korea , Kuwait , Kazakhstan , Lebanon , Liechtenstein , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Madagascar , Macedonia , Mali , Myanmar , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Malaysia , Mozambique , Namibia , Niger , Nigeria , Netherlands , Norway , Oman , Peru , Philippines , Pakistan , Poland , Portugal , Paraguay , Qatar , Reunion , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , Turks And Caicos Islands , Chad , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , Turkey , Taiwan , Tanzania , Ukraine , Uganda , Uruguay , Uzbekistan , Vietnam , XF , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Output

  • Output power capacity
    54.0 KWatts / 60.0 kVA
  • Max Configurable Power (Watts)
    54.0 KWatts / 60.0 kVA
  • Nominal Output Voltage
    400V 3PH
  • Neutral Output Current
    87A
  • Output Voltage Note
    kW/kVA = 0.9 PF with ambient temp up to 25° C. kW/kVA = 0.8 PF with ambient temp above 25° C
  • Efficiency at Full Load
    93.5 %
  • Output Voltage Distortion
    Less than 5%
  • Output Frequency (sync to mains)
    50/60 Hz +/- 5%
  • Output Frequency (not synced)
    50/60 Hz +/-1 Hz
  • Other Output Voltages
    380, 415
  • Load Crest Factor
    3 : 1
  • Topology
    Double Conversion Online
  • Overload Operation
    10 minutes @ 125% and 60 seconds @ 150%
  • Output Voltage THD
    < 3% linear load and <5% non-linear load
  • Output Voltage Tolerance
    +/- 2% static and 100% load step
  • Bypass
    Built-in Static Bypass

Input

  • Nominal Input Voltage
    400V 3PH
  • Input frequency
    45 - 65 Hz
  • Input Connections
    Hard Wire 5-wire (3PH + N + G)
  • Input voltage range for main operations
    340 - 477V
  • Input voltage adjustable range for mains operation
    323 - 437 (380V), 340 - 460 (400V), 357 - 477 (415V)V
  • Efficiency at Full Load
    93.5 %
  • Input Total Harmonic Distortion
    Less than 5% for full load
  • Type of Input Protection Required
    3-pole breaker
  • Other Input Voltages
    380, 415
  • Maximum Short Circuit Withstand (Icw)
    16.0kAmps
  • Maximum Input Current
    228.0A
  • Input Power Factor at Full Load
    99.0

Batteries & Runtime

Communications & Management

  • Control panel
    Multi-function LCD status and control console
  • Emergency Power Off (EPO)
    Yes

Physical

  • Maximum Height
    1900mm , 190.0CM
  • Maximum Width
    700mm , 70.0CM
  • Maximum Depth
    950mm , 95.0CM
  • Net Weight
    375.0KG
  • Shipping weight
    395.0KG
  • Shipping Height
    1978mm , 197.8CM
  • Shipping Width
    824mm , 82.4CM
  • Shipping Depth
    1120mm , 112.0CM

Environmental

  • Operating Temperature
    0 - 40 °C
  • Operating Relative Humidity
    0 - 95% non-condensing %
  • Operating Elevation
    0-900meters
  • Storage Temperature
    -15 - 40 °C
  • Storage Relative Humidity
    0 - 95% non-condensing %
  • Storage Elevation
    0-4500meters
  • Audible noise at 1 meter from surface of unit
    65.0dBA
  • Protection Class
    IP 20

Conformance

  • Approvals
    CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 62040-4, ISTA 2B
  • Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up

Sustainable Offer Status

  • RoHS
    Compliant

General

  • Bypass Connection
    5 wire (3PH + N + G)
Manuals and Warranties
Title
Size
Updated On
PDF

Size

1220KB

Updated On

2018-06-18

Providing the user with information on operation, maintenance and troubleshooting of the Galaxy 300 system
PDF

Size

1370KB

Updated On

2018-06-15

Providing the certified electrician with information on how to install the Galaxy 300 classic battery cabinet
PDF

Size

2298KB

Updated On

2018-06-13

Contains information about earthing principles for MGE Galaxy 3500, Smart-UPS VT and MGE Galaxy 300
PDF

Size

1637KB

Updated On

2018-06-11

Providing the certified electrician with information on how to install the Galaxy 300 UPS without internal batteries
Brochure
Title
Size
Updated On
PDF

Size

511KB

Updated On

2018-06-19

Galaxy 300 - 3 Phase power protection brochure
Design/Configuration
Title
Size
Updated On
PDF

Size

865KB

Updated On

2018-06-15

Battery runtime charts for standard non -modular battery configurations
PDF

Size

963KB

Updated On

2018-06-11

Contains Technical data, Facility planning, drawings, options
Agency Approvals
Title
Size
Updated On
PDF

Size

668KB

Updated On

2018-06-18

PDF

Size

72KB

Updated On

2018-06-15

Certificate of Origin
PDF

Size

191KB

Updated On

2018-06-15

EU Declaration of Conformity
Bid Spec
Title
Size
Updated On
PDF

Size

183KB

Updated On

2018-06-19

Bid spec for Galaxy 300 60-80 kVA 400 V
Source ZIP

Size

120KB

Updated On

2018-06-19

Bid spec for Galaxy 300 60-80 kVA 400 V

Firmware Upgrades

Firmware Upgrades
Part Number
Updated On

Firmware Upgrades

PowerNet MIB v4.2.6

Part Number

SFPMIB426

Updated On

2018-01-24
PowerChute Network Shutdown
Part Number
Updated On

PowerChute Network Shutdown

PowerChute Network Shutdown v4.2

Compatible With: Solaris , Solaris , Windows Server 2008 , Windows Server 2012 , Linux , Solaris , Solaris , HP-UX , AIX , Microsoft Hyper-V , Windows Server 2008 , Windows Server 2012 , Mac OS X , Linux

Part Number

SFPCNS42

Updated On

2016-08-23

PowerChute Network Shutdown

PowerChute Network Shutdown v4.2 for Virtualization

Compatible With: VMware ESXi , VMware ESX , VMware Virtual Appliance , Microsoft Hyper-V , Windows Server 2008 , Windows Server 2012

Part Number

SFPCNS42-V

Updated On

2016-08-23

Category

Sub-Category


Certified Operator Training for Galaxy 300 - 2 days - private session up to 6 trainees

Get the most from your Schneider Electric solution while learning from our industry proven professionals. Increase your knowledge and confidence operating your data center and managing your facility's physical infrastructure.

External Battery breaker box 60-80KVA

External battery breaker box for use with third party battery configurations. *Actual breaker may vary from image.


Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product