APC Smart-UPS SRT 2200VA RM 230V Network Card

Share:

APC Smart-UPS SRT 2200VA RM 230V Network Card

SRT2200RMXLI-NC

Description: High density, double-conversion on-line power protection with scalable runtime

Includes : CD with software , Country-specific detachable power cord , Documentation CD , Installation guide , Network Management Card , Rack Mounting brackets , Rack mounting hardware , Rack Mounting support rails , USB cable , Warranty card

APC Smart-UPS SRT 2200VA RM 230V Network Card

Call for More Information
44553010
Includes: CD with software , Country-specific detachable power cord , Documentation CD , Installation guide , Network Management Card , Rack Mounting brackets , Rack mounting hardware , Rack Mounting support rails , USB cable , Warranty card

Related Products, Accessories & Services

View all accessories and replacement batteries for this product

SRT2200RMXLI-NC Features

APC Smart-UPS SRT 2200VA RM 230V Network Card

  • Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • ECO Mode
    Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
  • LCD graphics display
    Text and mimic diagrams that display modes of operation, system parameters and alarms.
  • Rack/Tower convertible
    Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

Smart-UPS On-Line Features & Benefits

  • Predicitive failure notification
    Provides early-warning fault analysis ensuring proactive component replacement.
  • Disconnected battery notification
    Warns when a battery is not available to provide backup power.
  • Audible alarms
    Provides notification of changing utility power and UPS power conditions
  • User-replaceable batteries
    Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Rack/Tower convertible
    Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
  • Plug-and-Play external batteries
    Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
  • Flash upgradeable firmware
    Install maintenance releases of firmware remotely using FTP.
  • Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Resettable circuit breaker
    Easy recovery from overloads; no need to replace a fuse.
  • Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Power conditioning
    Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Cold-start capable
    Provides temporary battery power when the utility power is out.
  • Generator compatible
    Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Frequency and voltage regulation
    Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Avoids costly power problems by keeping your IT equipment and data protected and available.
    Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
  • Peace of mind that comes with full equipment compatibility and reliability of a leader
    Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
  • Save time with easy and convenient remote/network accessibility.
    Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
  • Low operating and maintenance costs with proven reliability and intelligent battery management.
    Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
  • InfraStruXure Manager Compatible
    Enables centralized management via the APC InfraStruXure Manager.
  • SmartSlot
    Customize UPS capabilities with management cards.
  • Network manageable
    Provides remote power management of the UPS over the network.
  • Serial connectivity
    Provides management of the UPS via a serial port.
  • LED status indicators
    Quickly understand unit and power status with visual indicators.
  • Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Scalable runtime
    Allows additional run time to be quickly added as needed.
  • Automatic internal bypass
    Supplies utility power to the connected loads in the event of a UPS power overload or fault.
  • Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Automatic restart of loads after UPS shutdown
    Automatically starts up the connected equipment upon the return of utility power.
Product Distribution
Product Distribution

Andorra , United Arab Emirates , Afghanistan , Antigua and Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Australia , Aruba , Azerbaijan , Bosnia and Herzegovina , Barbados , Bangladesh , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Bermuda , Brunei , Bolivia , Bahamas , Bhutan , Botswana , Belarus , Belize , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Cook Islands , Chile , Cameroon , Colombia , Costa Rica , Serbia and Montenegro , Cuba , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Dominica , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , Fiji , Falkland Islands , France , Gabon , United Kingdom , Grenada , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Guatemala , Guyana , Hong Kong , Honduras , Croatia , Haiti , Hungary , Indonesia , Ireland , Israel , Iraq , Iran , Iceland , Italy , Jamaica , Jordan , Kenya , Cambodia , Saint Kitts And Nevis , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , Saint Lucia , Liechtenstein , Sri Lanka , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Madagascar , Macedonia , Mali , Myanmar , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Malaysia , Mozambique , Namibia , Niger , Nigeria , Nicaragua , Netherlands , Norway , Nepal , New Zealand , Oman , Panama , Peru , Papua New Guinea , Philippines , Pakistan , Poland , Puerto Rico , Portugal , Paraguay , Qatar , Reunion , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Turks And Caicos Islands , Chad , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , TP , Turkey , Trinidad and Tobago , Tanzania , Ukraine , Uganda , Uruguay , Uzbekistan , Saint Vincent And The Grenadines , Venezuela , U.S. Virgin Islands , Vietnam , XF , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Output

  • Output power capacity
    1.98 KWatts / 2.2 kVA
  • Max Configurable Power (Watts)
    1.98 KWatts / 2.2 kVA
  • Nominal Output Voltage
    230V
  • Output Voltage Distortion
    Less than 2%
  • Output Frequency (sync to mains)
    50/60Hz +/- 3 Hz
  • Other Output Voltages
    220, 240
  • Load Crest Factor
    3 : 1
  • Topology
    Double Conversion Online
  • Waveform type
    Sine wave
  • Output Connections
    (2) IEC 320 C19 (Battery Backup)
    (8) IEC 320 C13 (Battery Backup)
    (2) IEC Jumpers (Battery Backup)
  • Bypass
    Built-in Bypass

Input

  • Nominal Input Voltage
    230V
  • Input frequency
    40 - 70 Hz (auto sensing)
  • Input Connections
    IEC-320 C20, Schuko CEE 7 / EU1-16P, British BS1363A
  • Cord Length
    2.44meters
  • Input voltage range for main operations
    160 - 275V
  • Input voltage adjustable range for mains operation
    100 - 275 (half load)V
  • Number of Power Cords
    1
  • Other Input Voltages
    220, 240

Batteries & Runtime

Communications & Management

  • Interface Port(s)
    RJ-45 10/100 Base-T , RJ-45 Serial , Smart-Slot , USB
  • Control panel
    Multi-function LCD status and control console
  • Audible Alarm
    Audible and visible alarms prioritized by severity
  • Emergency Power Off (EPO)
    Yes
  • Available SmartSlot™ Interface Quantity
    1

Surge Protection and Filtering

  • Surge energy rating
    340Joules
  • Filtering
    --

Physical

  • Maximum Height
    85mm , 8.5CM
  • Maximum Width
    432mm , 43.2CM
  • Maximum Depth
    584mm , 58.4CM
  • Rack Height
    2U
  • Net Weight
    25.0KG
  • Shipping weight
    34.02KG
  • Shipping Height
    246mm , 24.6CM
  • Shipping Width
    599mm , 59.9CM
  • Shipping Depth
    810mm , 81.0CM
  • Color
    Black
  • Units per Pallet
    12.0

Environmental

  • Operating Temperature
    0 - 40 °C
  • Operating Relative Humidity
    0 - 95% non-condensing %
  • Operating Elevation
    0-3000meters
  • Storage Temperature
    -20 - 50 °C
  • Storage Relative Humidity
    0 - 95% non-condensing %
  • Storage Elevation
    0-15000meters
  • Audible noise at 1 meter from surface of unit
    55.0dBA
  • Online thermal dissipation
    535.0BTU/hr
  • Protection Class
    IP 20

Conformance

  • Approvals
    CE, CE Mark, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, VDE
  • Standard warranty
    3 years repair or replace (excluding battery) and 2 years for battery

Sustainable Offer Status

  • RoHS
    Compliant
  • REACH
    REACH: Contains No SVHCs
  • Battery Directive
    Compliant
Manuals and Warranties
Title
Size
Updated On
PDF

Size

495KB

Updated On

2018-06-11

Installation manual for Smart-UPS On-Line SRTRK4 Tower to Rack-Mount Conversion
PDF

Size

1213KB

Updated On

2018-06-11

Installation guide Smart-UPS Online SRTRK3
PDF

Size

393KB

Updated On

2018-06-08

User manual for Smart-UPS On-Line SRT2200/SRT3000 Tower/Rack-Mount 2U
PDF

Size

320KB

Updated On

2018-06-07

Operation manual Smart-UPS On-Line SRT2200/SRT3000 Tower/Rack-Mount 2U
Brochure
Title
Size
Updated On
PDF

Size

2485KB

Updated On

2018-06-12

Part # 998-1243569_GMA-US This is a brochure of the new Smart-UPS On-Line SRT 2.2kVA-10kVA 230V models . It covers the feature/benefits, tech specs, runtimes and optional accessories.
Agency Approvals
Title
Size
Updated On
PDF

Size

3016KB

Updated On

2018-06-19

EN 62040-2:2006 Category C2; IEC 62040-2:2005 Category C2; EN 5022:2010 + AC:2011, Class A; IEC 61000-3-2:2014 ED.4.0, Class A; IEC 61000-3-3:2013 ED.3.0; IEC 61000-4-2:2008 ED.2.0; IEC 61000-4-3:2010 ED.3.2; IEC 61000-4-4:2012 ED.3.0; IEC 61000-4-5:2005 ED.2.0; IEC 61000-4-6:2013 ED.4.0; IEC 61000-4-8:2009 ED.2.0; IEC 61000-4-11:2004 ED.2.0; IEC 61000-2-2:2002 ED.2.0
PDF

Size

1688KB

Updated On

2018-06-14

IEC 62040-1 (ed.1);am1
PDF

Size

756KB

Updated On

2018-06-13

DIN EN 62040-1 (VDE 0558-510): 2013-11; EN 62040-1:2008+A1:2013
PDF

Size

1529KB

Updated On

2018-06-12

IEC 62040-1 (ed.1);am1
PDF

Size

130KB

Updated On

2018-06-07

2014/35/EU, 2014/30/EU, 2011/65/EU
Bid Spec
Title
Size
Updated On
Source ZIP

Size

65KB

Updated On

2018-06-14

Guide Specification
PDF

Size

450KB

Updated On

2018-06-14

Guide Specification
Title
Size
Updated On

Firmware Upgrades

Firmware Upgrades
Part Number
Updated On

Firmware Upgrades

PowerNet MIB v4.2.6

Part Number

SFPMIB426

Updated On

2018-01-24
PowerChute Network Shutdown
Part Number
Updated On

PowerChute Network Shutdown

PowerChute Network Shutdown v4.2

Compatible With: Solaris , Solaris , Linux , Solaris , Microsoft Hyper-V , Windows Server 2008 , Windows Server 2012 , Mac OS X , Solaris , Windows Server 2008 , Windows Server 2012 , Linux , AIX , HP-UX

Part Number

SFPCNS42

Updated On

2016-08-23

PowerChute Network Shutdown

PowerChute Network Shutdown v4.2 for Virtualization

Compatible With: VMware ESXi , VMware Virtual Appliance , Microsoft Hyper-V , Windows Server 2008 , Windows Server 2012 , VMware ESX

Part Number

SFPCNS42-V

Updated On

2016-08-23

Category

Sub-Category


APC Smart-UPS SRT 6000VA 230V

High density, double-conversion on-line power protection with scalable runtime

APC Smart-UPS SRT 6000VA RM 230V

High density, double-conversion on-line power protection with scalable runtime

APC Smart-UPS SRT 10000VA 230V

High density, double-conversion on-line power protection with scalable runtime

APC Smart-UPS SRT 6000VA RM 230V Marine

High availability, ruggedized power protection for shipboard and other transportation applications.

APC Replacement Battery Cartridge #141

Genuine APC RBC(TM) are tested and certified for compatibility to restore UPS performance to the original specifications.


Show results per page