SYA16K16IXR Features

APC Symmetra LX 16kVA Scalable to 16kVA N+1 Ext. Run Tower, 220/230/240V or 380/400/415V

  • Removable input/output wiring tray
    Allows quick and easy installation and maintenance of the UPS.

Symmetra Features & Benefits

  • Avoids costly power problems by keeping your IT equipment and data protected and available.
    Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
  • Modular, Scalable, Redundant Architecture future proof initial investment, improves equipment availability, and simplifies maintenance.
    Symmetra LX’s redundant N+1 architecture enables the unit to withstand a failures of an intelligence module, battery or power module. Modules are easily replaceable in the field. Customers can add additional power modules or batteries after initial equipment purchase to accommodate loads of up to 16 kVA.
  • Low operating and maintenance costs with proven reliability and intelligent battery management.
    Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
  • Save time with easy and convenient remote accessibility.
    Network manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
  • Peace of mind that comes with complete equipment compatibility and reliability of a market leader.
    Safety agency tested and approved means that you can deploy Symmetra with confidence that they meet or exceed the industry’s most rigorous standards.
  • Frequency and voltage regulation
    Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Power conditioning
    Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Generator compatible
    Ensures clean, uninterrupted power to the loads in the event of an extended power outage
  • Cold-start capable
    Provides temporary battery power when the utility power is out.
  • Resettable circuit breakers
    Enables a quick recovery from overload events.
  • Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Audible alarms
    Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
  • Predictive failure notification
    Provides early-warning fault analysis ensuring proactive component replacement.
  • User-replaceable batteries
    Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Disconnected battery notification
    Warns when a battery is not available to provide backup power.
  • User-replaceable intelligence modules
    Enables simple upgrades and replacements of the Intelligence Modules.
  • User-replaceable power modules
    Enables simple upgrades and replacements of the Power Modules.
  • LCD display
    Alpha-Numeric Display which displays system parameters and alarms.
  • InfraStruXure Manager Compatible
    Enables centralized management via the APC InfraStruXure Manager.
  • SmartSlot
    Customize UPS capabilities with management cards.
  • Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Manageable external batteries
    Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
  • Network manageable
    Provides remote power management of the UPS over the network.
  • Scalable power capacity
    Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
  • Scalable runtime
    Allows additional run time to be quickly added as needed.
  • Plug-and-Play external batteries
    Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
  • Field-replaceable power distribution panel
    Ensures compatibility with equipment that has different plug types.
  • Programmable frequency
    Ensures compatibility with different input frequencies.
  • Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Hot-swappable power modules
    Ensures clean, uninterrupted power to protected equipment during Power Module replacement.
  • Hot-swappable intelligence modules
    Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.
  • Redundant Intelligence Modules
    Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
  • Configurable for N+1 internal redundancy
    Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
  • Modular design
    Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
  • Automatic internal bypass
    Supplies utility power to the connected loads in the event of a UPS power overload or fault.
  • Automatic restart of loads after UPS shutdown
    Automatically starts up the connected equipment upon the return of utility power.
  • Power Modules connected in parallel
    Enhances availability by allowing immediate, seamless recovery from isolated module failures.
  • Battery modules connected in parallel
    Delivers higher availability through redundant batteries.
Product Distribution
Product Distribution

Andorra , United Arab Emirates , Afghanistan , Antigua and Barbuda , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Australia , Azerbaijan , Bosnia and Herzegovina , Bangladesh , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Brunei , Bolivia , Brazil , Bhutan , Botswana , Belarus , The Democratic Republic Of Congo , Central African Republic , Congo , Switzerland , Côte d'Ivoire , Cook Islands , Chile , Cameroon , Serbia and Montenegro , Cyprus , Czech Republic , Germany , Djibouti , Denmark , Dominica , Algeria , Estonia , Egypt , Western Sahara , Eritrea , Spain , Ethiopia , Finland , Fiji , Falkland Islands , France , Gabon , United Kingdom , Grenada , Georgia , French Guiana , Ghana , Gibraltar , Gambia , Guinea , Guadeloupe , Equatorial Guinea , Greece , Hong Kong , Croatia , Hungary , Indonesia , Ireland , Israel , India , Iraq , Iran , Iceland , Italy , Jamaica , Jordan , Kenya , Cambodia , Saint Kitts And Nevis , South Korea , Kuwait , Kazakhstan , Lebanon , Saint Lucia , Liechtenstein , Sri Lanka , Liberia , Lesotho , Lithuania , Luxembourg , Latvia , Morocco , Moldova , Madagascar , Macedonia , Mali , Myanmar , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Malaysia , Mozambique , Namibia , Niger , Nigeria , Netherlands , Norway , Nepal , New Zealand , Oman , Peru , Papua New Guinea , Philippines , Pakistan , Poland , Portugal , Paraguay , Qatar , Reunion , Romania , Russia , Rwanda , Saudi Arabia , Sudan , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , Turks And Caicos Islands , Chad , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , TP , Turkey , Taiwan , Tanzania , Ukraine , Uganda , Uruguay , Uzbekistan , Saint Vincent And The Grenadines , Vietnam , XF , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Output

  • Output power capacity
    11.2 KWatts / 16.0 kVA
  • Max Configurable Power (Watts)
    11.2 KWatts / 16.0 kVA
  • Nominal Output Voltage
    230V
  • Output Voltage Note
    Configurable for 220 : 230 or 240 nominal output voltage
  • Output Voltage Distortion
    Less than 5% at full load
  • Output Frequency (sync to mains)
    47 - 63 Hz
  • Output Frequency (not synced)
    60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
  • Other Output Voltages
    220, 240
  • Load Crest Factor
    up to 5 : 1
  • Topology
    Double Conversion Online
  • Waveform type
    Sine wave
  • Maximum Output Current
    73
  • Output Connections
    (1) Hard Wire 3-wire (H N + G) (Battery Backup)
  • Bypass
    Internal Bypass (Automatic and Manual)

Input

  • Nominal Input Voltage
    230V , 400V 3PH
  • Input frequency
    45 - 65 Hz (auto sensing)
  • Input Connections
    Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH + N + G)
  • Input voltage range for main operations
    155 - 276 (1:1), 290 - 480 (3:1)V
  • Input Total Harmonic Distortion
    Less than 7% for full load
  • Other Input Voltages
    220V, 240V, 380V, 415V
  • Input Power Factor at Full Load
    0.98

Batteries & Runtime

Communications & Management

  • Interface Port(s)
    DB-9 RS-232 , RJ-45 10/100 Base-T , Smart-Slot
  • Pre-Installed SmartSlot™ Cards
    AP9631
  • Control panel
    Multi-function LCD status and control console
  • Audible Alarm
    Audible and visible alarms prioritized by severity
  • Emergency Power Off (EPO)
    Yes
  • Available SmartSlot™ Interface Quantity
    1

Physical

  • Maximum Height
    1516mm , 151.6CM
  • Maximum Width
    483mm , 48.3CM
  • Maximum Depth
    726mm , 72.6CM
  • Net Weight
    503.64KG
  • Shipping weight
    535.45KG
  • Shipping Height
    1880mm , 188.0CM
  • Shipping Width
    599mm , 59.9CM
  • Shipping Depth
    997mm , 99.7CM
  • Color
    Black , Silver
  • Units per Pallet
    1.0

Environmental

  • Operating Temperature
    0 - 40 °C
  • Operating Relative Humidity
    0 - 95 %
  • Operating Elevation
    0-3000meters
  • Storage Temperature
    -15 - 45 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0-4500meters
  • Audible noise at 1 meter from surface of unit
    62.0dBA
  • Online thermal dissipation
    3707.0BTU/hr

Conformance

  • Approvals
    C-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 55024, EN 60950, GOST, IEC 60950, VDE
  • Standard warranty
    2 years repair or replace
Manuals and Warranties
Title
Size
Updated On
PDF

Size

2264KB

Updated On

2018-07-10

Symmetra LX Tower Installation 220/230/240 VAC
PDF

Size

116KB

Updated On

2018-07-03

Warranty Registration Card
PDF

Size

664KB

Updated On

2018-06-15

Safety
PDF

Size

712KB

Updated On

2018-06-15

The Symmetra RT Safety and General Information manual contains:; - safety instructions; - radio frequency interference information; - life support policy; - limited warrenty
PDF

Size

263KB

Updated On

2018-06-15

Installation
PDF

Size

840KB

Updated On

2018-06-14

Electrical installation guide for Symmetra LX 220/230/240 Vac Tower/Rack-Mount
PDF

Size

1248KB

Updated On

2018-06-14

The manual contains information on how to operate the Powerview for the Symmetra RT UPS.
PDF

Size

326KB

Updated On

2018-06-14

Safety; Installation
PDF

Size

876KB

Updated On

2018-06-12

Physical Installation instructions for Symmetra LX 220/230/240 VAC
PDF

Size

1613KB

Updated On

2018-06-12

Start up manaul for Symmetra LX 220/230/240 VAC
Design/Configuration
Title
Size
Updated On
PDF

Size

9173KB

Updated On

2018-06-14

Contains Technical Data, Facility Planning, Connections, Drawings, Options, Warranty
Agency Approvals
Title
Size
Updated On
PDF

Size

3133KB

Updated On

2018-06-19

Includes Models: SYAF8KI, SYAF8KRMI, SYAF16KI, SYAF16KRMI, SYAF16KXR9I, SYAF20KRMI, SYBRXR3RMI, SYBFXR9I, SYBFXR9RMI, SYA4K8I, SYA4K8RMI, SYA8K16I, SYA8K16IXR, SYA8K16RMI, SYA8K8I, SYA8K8RMI, SYA12K16I, SYA12K16RMI, SYA16K16I, SYA16K16IXR, SYA16K16RMI.
PDF

Size

41KB

Updated On

2018-06-12

Declaration of Conformity Uninterruptible Power Supply (Symmetra Single Phase)
Bid Spec
Title
Size
Updated On
PDF

Size

432KB

Updated On

2018-06-12

Guide Specification
Source ZIP

Size

69KB

Updated On

2018-06-12

Guide Specification

Firmware Upgrades

Firmware Upgrades
Part Number
Updated On

Part Number

SFRMPV0014

Updated On

2006-07-19

Part Number

SFSY372

Updated On

2010-02-04
Wizards and Configurators
Part Number
Updated On

Part Number

SFNMCSECWIZ104

Updated On

2010-04-16
InfraStruxure Manager
Part Number
Updated On

Part Number

AP9430

Updated On

2018-05-23

Part Number

AP9431

Updated On

2018-05-23
Additional Software
Part Number

Category

Sub-Category


APC Symmetra LX Castor kit- right front, left rear

Highly available single phase UPS features redundant and scalable double-conversion on-line power protection

APC Symmetra LX top panel

Highly available single phase UPS features redundant and scalable double-conversion on-line power protection

1 Year of Remote Monitoring Service for (25) Nodes

A 7x24 monitoring service that acts as a primary or secondary support function. Trained technicians will monitor the health status of the physical infrastructure to help diagnose, notify and resolve problems before they become critical.

(1) Stand Alone PM Visit for (1) UPS up to 40 kVA UPS

Performed at any point for your UPS or cooling system lifecycle, regardless of your service contract status. On-demand services include part replacement services for batteries, parts, reactive time and materials (T&M), etc.

APC Symmetra LX 32U replacement door

Highly available single phase UPS features redundant and scalable double-conversion on-line power protection

3 Year Concurrent Extended Warranty for (1) Symmetra 13-16K

Get an extension of factory warranty coverage beyond the original factory warranty term for peace of mind and protection from failure

APC Symmetra LX Castor kit- left front, right rear

Highly available single phase UPS features redundant and scalable double-conversion on-line power protection

Scheduling Upgrade to 7X24 for Existing PM or Addnl PM Visit for up to 40 kVA UPS

Performed at any point for your UPS or cooling system lifecycle, regardless of your service contract status. On-demand services include part replacement services for batteries, parts, reactive time and materials (T&M), etc.


Show results per page