InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14

InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Left
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Left
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Left
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Right
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Front Straight
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Back
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14 Miscellaneous
  • Close-coupled, chilled water cooling for medium to large data centers

  • Includes: Installation Guide, Operations and Maintenance Manual

View Product Overview

ACRC101 Features

InRow RC Chilled Water, 200-240V 50/60 Hz, IEC 320-C14
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation Guide, Operations and Maintenance Manual
  • Hot swappable fans
    Allows system to remain operational if a fan replacement is required.
  • Modular design
    Increases adaptability with an open architecture configurable to any IT environment.
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Rack inlet control
    Rack inlet control guarantees inlet temperature to IT equipment.
  • Top or Bottom Piping Connections
    The unit includes both top and bottom piping connections.

InRow Chilled Water Cooling Features & Benefits

Total Cost of Ownership

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Availability

Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Manageability

Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time Capacity Monitoring
Real-time display of current and available cooling.

Agility

Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Casters
Provides flexibility to move the unit to wherever cooling is required.

Product Distribution

Andorra, United Arab Emirates, Afghanistan, Antigua and Barbuda, Anguilla, Albania, Armenia, Netherlands Antilles, Angola, Argentina, Austria, Australia, Aruba, Azerbaijan, Bosnia and Herzegovina, Barbados, Bangladesh, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, Bermuda, Brunei, Bolivia, Brazil, Bahamas, Bhutan, Botswana, Belarus, Belize, Canada, The Democratic Republic Of Congo, Central African Republic, Congo, Switzerland, Côte d'Ivoire, Cook Islands, Chile, Cameroon, China, Colombia, Costa Rica, Serbia and Montenegro, Cuba, Cyprus, Czech Republic, Germany, Djibouti, Denmark, Dominica, Dominican Republic, Algeria, Ecuador, Estonia, Egypt, Western Sahara, Eritrea, Spain, Ethiopia, Finland, Fiji, Falkland Islands, France, Gabon, United Kingdom, Grenada, Georgia, French Guiana, Ghana, Gibraltar, Gambia, Guinea, Guadeloupe, Equatorial Guinea, Greece, Guatemala, Guyana, Hong Kong, Honduras, Croatia, Haiti, Hungary, Indonesia, Ireland, Israel, India, Iraq, Iran, Iceland, Italy, Jamaica, Jordan, Japan, Kenya, Saint Kitts And Nevis, South Korea, Kuwait, Cayman Islands, Kazakhstan, Lebanon, Saint Lucia, Liechtenstein, Sri Lanka, Liberia, Lesotho, Lithuania, Luxembourg, Latvia, Morocco, Moldova, Madagascar, Macedonia, Mali, Myanmar, Mongolia, Martinique, Mauritania, Malta, Mauritius, Malawi, Mexico, Malaysia, Mozambique, Namibia, Niger, Nigeria, Nicaragua, Netherlands, Norway, Nepal, New Zealand, Oman, Panama, Peru, Papua New Guinea, Philippines, Pakistan, Poland, Puerto Rico, Portugal, Paraguay, Reunion, Romania, Russia, Rwanda, Saudi Arabia, Sudan, Sweden, Singapore, Slovenia, Slovakia, Sierra Leone, Senegal, Somalia, Suriname, El Salvador, Turks And Caicos Islands, Chad, Togo, Thailand, Tajikistan, Turkmenistan, TP, Turkey, Trinidad and Tobago, Taiwan, Tanzania, Ukraine, Uganda, United States, Uruguay, Uzbekistan, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands, Vietnam, XF, Yemen, Mayotte, South Africa, Zambia, Zimbabwe

Input

Nominal Input Voltage
200V
Input frequency
50/60 Hz
Input Connections
IEC-320 C14
Number of Power Cords
2
Input Power
1380.0Watts

Communications & Management

Control panel
Multi-function LCD status and control console

Physical

Maximum Height
1991MM, 199.11CM
Maximum Width
300MM, 29.97CM
Maximum Depth
1069MM, 106.88CM
Rack Height
42U
Net Weight
162.73KG
Shipping weight
193.41KG
Shipping Height
2118MM, 211.81CM
Shipping Width
746MM, 74.63CM
Shipping Depth
1137MM, 113.67CM
Color
Black
Units per Pallet
1.0

Environmental

Audible noise at 1 meter from surface of unit
79.0dBA

Conformance

Approvals
cUL Listed, C-tick, CE, EN 55022 Class A, EN 55024, EN 60950, EN 61000-3-2, Eurovent, FCC Part 15 Class A, GS Mark, ICES-003, IEC 60950, IEC 61000-3-2, IEC 61000-3-3, Industry Canada, UL Listed, VCCI, VDE
Standard warranty
1 year (parts only)

Sustainable Offer Status

Other Environmental Compliance
China RoHS

General

Minimum Water Inlet Temperature
7.0 °C

Options

Services