In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16

In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Left
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Left
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Left
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Left
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Right
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Front Straight
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Back
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16 Miscellaneous
  • Close-coupled, chilled water cooling for medium to large data centers

  • Includes: Installation Guide, Operations and Maintenance Manual

View Product Overview

ACRC103 Features

In Row RC Chilled Water, 200-240V 50/60 Hz, IEC 309-16
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation Guide, Operations and Maintenance Manual
  • Hot swappable fans
    Allows system to remain operational if a fan replacement is required.
  • Washable filters
    Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

InRow Chilled Water Cooling Features & Benefits

Total Cost of Ownership

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Availability

Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Manageability

Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time Capacity Monitoring
Real-time display of current and available cooling.

Agility

Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Casters
Provides flexibility to move the unit to wherever cooling is required.

Product Distribution

Andorra, Afghanistan, Albania, Armenia, Angola, Argentina, Austria, Australia, Azerbaijan, Bosnia and Herzegovina, Bangladesh, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, Brunei, Bhutan, Botswana, Belarus, Canada, Central African Republic, Congo, Switzerland, Côte d'Ivoire, Cook Islands, Chile, Cameroon, China, Serbia and Montenegro, Cyprus, Czech Republic, Germany, Djibouti, Denmark, Algeria, Estonia, Egypt, Western Sahara, Eritrea, Spain, Ethiopia, Finland, Fiji, France, Gabon, United Kingdom, Georgia, Ghana, Gibraltar, Gambia, Guinea, Equatorial Guinea, Greece, Hong Kong, Croatia, Hungary, Indonesia, Ireland, Israel, India, Iraq, Iran, Iceland, Italy, Jordan, Japan, Kenya, Cambodia, South Korea, Kuwait, Cayman Islands, Kazakhstan, Lebanon, Liechtenstein, Sri Lanka, Liberia, Lesotho, Lithuania, Luxembourg, Latvia, Morocco, Moldova, Macedonia, Mali, Myanmar, Mongolia, Mauritania, Malta, Malaysia, Mozambique, Namibia, Niger, Nigeria, Netherlands, Norway, Nepal, New Zealand, Oman, Papua New Guinea, Philippines, Pakistan, Poland, Portugal, Romania, Russia, Rwanda, Sudan, Sweden, Singapore, Slovenia, Slovakia, Sierra Leone, Senegal, Somalia, Suriname, Chad, Togo, Thailand, Tajikistan, Turkmenistan, Tunisia, TP, Turkey, Taiwan, Tanzania, Ukraine, Uganda, United States, Uzbekistan, Vietnam, XF, Yemen, South Africa, Zambia, Zimbabwe

Input

Nominal Input Voltage
200V
Input frequency
50/60 Hz
Input Connections
IEC 309 16A 2P+E
Number of Power Cords
2
Input Power
1000.0Watts

Communications & Management

Control panel
Multi-function LCD status and control console
Audible Alarm
Audible and visible alarms prioritized by severity

Physical

Maximum Height
1991MM, 199.1CM
Maximum Width
300MM, 30.0CM
Maximum Depth
1070MM, 107.0CM
Rack Height
42U
Net Weight
162.73KG
Shipping weight
193.41KG
Shipping Height
2118MM, 211.8CM
Shipping Width
746MM, 74.6CM
Shipping Depth
1137MM, 113.7CM
Color
Black
Units per Pallet
1.0

Conformance

Approvals
C-tick, CE, EN 55022 Class A, EN 55024, EN 60950, GOST, IEC 60950, IEC 61000-3-2, IEC 61000-3-3, MEA, VDE
Standard warranty
1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

General

Air Discharge Patterns
Horizontal
Air Flow
1368.64lps
Condensate Pump Capacity
0.002lps
Intake Air
Rear Return
Minimum Water Inlet Temperature
7.0 °C

Options

Services