APC SurgeArrest + Battery Backup 325VA German

APC SurgeArrest + Battery Backup 325VA German Front Left
APC SurgeArrest + Battery Backup 325VA German Front Left
APC SurgeArrest + Battery Backup 325VA German Front Left
APC SurgeArrest + Battery Backup 325VA German Front Left
APC SurgeArrest + Battery Backup 325VA German Front Left
APC SurgeArrest + Battery Backup 325VA German Front Right
APC SurgeArrest + Battery Backup 325VA German Front Straight
APC SurgeArrest + Battery Backup 325VA German Back
APC SurgeArrest + Battery Backup 325VA German Front Left
APC SurgeArrest + Battery Backup 325VA German Front Left
APC SurgeArrest + Battery Backup 325VA German Front Left
APC SurgeArrest + Battery Backup 325VA German Front Right
APC SurgeArrest + Battery Backup 325VA German Front Straight
APC SurgeArrest + Battery Backup 325VA German Back
Green Premium™
RoHS
  • Battery Backup & Surge Protector for Electronics and Computers

  • Includes: User manual

View Product Overview

BE325-GR Features

Key Features

Run time for load W
Run time for load
Enter the total load (power draw) of all devices to be protected by the UPS here. Based on the value entered we will estimate the run time that you will have during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.

The total load (power draw) entered exceeds the maximum value for this product (185W)

Please enter load to see estimated run time

Max. Capacity Used
Max. Capacity Used
The maximum percentage of UPS capacity used to support your specified load.

Please enter load to see calculated "Max. Capacity Used"

Output power capacity
185 Watts / 325VA
Output Connections
(2) Schuko CEE 7 (Battery Backup)
(2) Schuko CEE 7 (Surge Protection)
Nominal Output Voltage
230V
Nominal Input Voltage
230V
Input Connections
Schuko CEE 7/7P
Cord Length
1.8meters
Maximum Input Current
4.0A
APC SurgeArrest + Battery Backup 325VA German
Battery Backup & Surge Protector for Electronics and Computers
Includes: User manual

Back-UPS Features & Benefits

Safety

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Availability

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Manageability

Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status display
Quickly understand unit and power status with visual indicators.

Protection

Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.

Marketing features

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Product Distribution

Albania, Netherlands Antilles, Angola, Austria, Azerbaijan, Bosnia and Herzegovina, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, The Democratic Republic Of Congo, Côte d'Ivoire, Cameroon, Czech Republic, Germany, Estonia, Egypt, Eritrea, Ethiopia, Finland, Gabon, Greece, Croatia, Hungary, Ireland, Israel, Iraq, Iceland, Jordan, Cambodia, Kuwait, Kazakhstan, Lebanon, Liberia, Lithuania, Luxembourg, Latvia, Morocco, Macedonia, Mongolia, Mauritania, Mozambique, Netherlands, Norway, Oman, Pakistan, Romania, Rwanda, Sweden, Slovenia, Slovakia, Senegal, Somalia, Suriname, Turkmenistan, Tunisia, Uganda

Technical Specifications

Output

Max Configurable Power (Watts)
185 Watts / 325VA
Output Frequency (sync to mains)
47 - 63 Hz Sync to mains
Topology
Standby
Waveform type
Stepped approximation to a sinewave
Maximum Output Current
4
Transfer Time
4 ms typical : 8 ms maximum

Input

Input frequency
50 Hz +/- 3 Hz
Input voltage range for main operations
180 - 266V
Number of Power Cords
1

Batteries & Runtime

Battery type
Lead-acid battery
Typical recharge time
24hour(s)
Replacement Battery
Expected Battery Life (years)
3 - 5
RBC Quantity
1
Battery Charge Power (Watts)
2 Watts
Battery Volt-Amp-Hour Capacity
43

Communications & Management

Control panel
LED Status display with on line : on battery
Audible Alarm
Alarm when on battery : distinctive low battery alarm

Surge Protection and Filtering

Surge energy rating
310Joules
Data Line Protection
RJ11 modem/fax/DSL protection (two wire single line)

Physical

Maximum Height
115MM, 11.5CM
Maximum Width
360MM, 36.0CM
Maximum Depth
95MM, 9.5CM
Net Weight
4.0KG
Shipping weight
4.6KG
Shipping Height
153MM, 15.3CM
Shipping Width
465MM, 46.5CM
Shipping Depth
116MM, 11.6CM
Color
Charcoal
Master Carton Dimensions (Length x Width x Height)
245MM
Master Carton Units
1.0
Master Carton Weight
18.76
Units per Pallet
64.0
SCC Codes
10731304211140

Environmental

Operating Temperature
0 - 40 °C
Operating Relative Humidity
5 - 95 %
Operating Elevation
0 - 3048meters
Storage Temperature
-15 - 45 °C
Storage Elevation
0 - 15240meters
Audible noise at 1 meter from surface of unit
45.0dBA
Online thermal dissipation
31.0BTU/hr

Conformance

Approvals
CE, EN 50091-1, EN 50091-2, GS Mark, NEMKO
Equipment protection policy
Lifetime : 75000 euros
Standard warranty
2 years repair or replace

Sustainable Offer Status

RoHS
Compliant
PEP
Available in Documentation tab
EOLI
Available in Documentation tab

Options