InRow RD, 300mm, Fluid Cooled, 220-240V, 50Hz

InRow RD, 300mm, Fluid Cooled, 220-240V, 50Hz Front Left
InRow RD, 300mm, Fluid Cooled, 220-240V, 50Hz Front Left
InRow RD, 300mm, Fluid Cooled, 220-240V, 50Hz Front Left
InRow RD, 300mm, Fluid Cooled, 220-240V, 50Hz Detailed
InRow RD, 300mm, Fluid Cooled, 220-240V, 50Hz Detailed
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 244ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 153ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers

  • Includes: Installation guide, Operations and maintenance manual

View Product Overview

ACRD201 Features

InRow RD, 300mm, Fluid Cooled, 220-240V, 50Hz
Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers
Includes: Installation guide, Operations and maintenance manual
  • Containment system compatible
    The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency
  • Head pressure control
    Modulates refrigerant head pressure to protect from coil freeze.
  • Hot swappable fans
    Allows system to remain operational if a fan replacement is required.
  • Washable filters
    Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

InRow Direct Expansion Features & Benefits

Manageability

Real-Time capacity monitoring
Real-time display of current and available cooling.
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Microprocessor controller
Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display

Agility

Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Availability

Rack inlet temperature control
Reduces the risk of hot spots at the rack level
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Total Cost of Ownership

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Product Distribution

Afghanistan, Armenia, Argentina, Austria, Australia, Azerbaijan, Bangladesh, Belgium, Bulgaria, Brunei, Bolivia, Bhutan, Belarus, Switzerland, Cook Islands, Chile, China, Czech Republic, Germany, Denmark, Algeria, Spain, Fiji, France, United Kingdom, Georgia, Hong Kong, Hungary, Indonesia, Ireland, Israel, India, Iceland, Italy, Cambodia, South Korea, Kazakhstan, Sri Lanka, Liberia, Morocco, Moldova, Myanmar, Mongolia, Malaysia, Netherlands, Norway, Nepal, New Zealand, Papua New Guinea, Philippines, Pakistan, Poland, Portugal, Paraguay, Romania, Russia, Sweden, Singapore, Thailand, Tajikistan, Turkmenistan, Tunisia, TP, Turkey, Taiwan, Ukraine, Uruguay, Uzbekistan, Vietnam, XF, South Africa