MasterSwitch Pwr Recept, 2U, 15A, 120V, (2)5-15

MasterSwitch Pwr Recept, 2U, 15A, 120V, (2)5-15 Front Left
MasterSwitch Pwr Recept, 2U, 15A, 120V, (2)5-15 Front Left
MasterSwitch Pwr Recept, 2U, 15A, 120V, (2)5-15 Front Left
MasterSwitch Pwr Recept, 2U, 15A, 120V, (2)5-15 Front Right
MasterSwitch Pwr Recept, 2U, 15A, 120V, (2)5-15 Front Left
MasterSwitch Pwr Recept, 2U, 15A, 120V, (2)5-15 Front Right
  • Switched Rack Power Distribution Units (Rack PDU) provide advanced load management plus on/off control at the outlet level for power cycling, delayed power sequencing ...

  • Includes: User Manual

View Product Overview

AP9510515 Features

Key Features

Rack Height
2U
Output Connections
(2) NEMA 5-15R (Battery Backup)
Nominal Output Voltage
120V
Nominal Input Voltage
120V
Input Connections
NEMA 5-15P
Cord Length
3.05meters
MasterSwitch Pwr Recept, 2U, 15A, 120V, (2)5-15
Switched Rack Power Distribution Units (Rack PDU) provide advanced load management plus on/off control at the outlet level for power cycling, delayed power sequencing, and outlet use management.
Includes: User Manual

NetShelter Switched Rack PDUs Features & Benefits

Adaptability

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Marketing features

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Manageability

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Network port sharing
Allows four rack PDUs to be connected using In and Out ports so that only one network connection is necessary.
Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Multi-tier user access
Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.
Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Product Distribution

Antigua and Barbuda, Anguilla, Netherlands Antilles, Argentina, Aruba, Barbados, Bermuda, Bolivia, Brazil, Bahamas, Belize, Canada, Chile, Colombia, Costa Rica, Cuba, Dominica, Dominican Republic, Ecuador, Falkland Islands, Grenada, Guadeloupe, Guatemala, Guyana, Honduras, Haiti, Jamaica, Saint Kitts And Nevis, Cayman Islands, Saint Lucia, Martinique, Mexico, Nicaragua, Panama, Peru, Puerto Rico, Paraguay, El Salvador, Turks And Caicos Islands, Trinidad and Tobago, United States, Uruguay, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands

Technical Specifications

Output

Overload Protection
No
Maximum Total Current Draw
12

Input

Input frequency
50/60 Hz
Acceptable Input Voltage
90-132VAC
Number of Power Cords
1
Load Capacity
1800VA
Maximum Input Current
15A
Maximum Line Current
15A

Physical

Maximum Height
84MM, 8.38CM
Maximum Width
140MM, 13.97CM
Maximum Depth
130MM, 12.95CM
Net Weight
1.82KG
Shipping weight
2.18KG
Shipping Height
330MM, 33.02CM
Shipping Width
140MM, 13.97CM
Shipping Depth
178MM, 17.78CM
Color
Beige
Units per Pallet
200.0

Environmental

Operating Temperature
0 - 45 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0-3000meters
Storage Temperature
-15 - 65 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0-9000meters

Conformance

Approvals
CSA, CSA 22.2 No. 950, UL 1950, UL Listed
Equipment protection policy
--
Standard warranty
2 years repair or replace

Options