APC WW 10KVA Isolation Transformer
-
The Step-Down Transformer converts high voltage (208 or 200 VAC) output into low voltage (120 or 100 VAC) output for powering low voltage AC equipment.
-
Includes: Documentation CD, Hardwire panel, Installation guide, Mounting hardware, Rack mounting brackets, User manual
APTF10KW01 Features
Key Features
Rack Height
4U
Output Connections
(1)
Hard wire 3-wire (H N + E)
Nominal Output Voltage
120V, 208V, 230V, 240V
Nominal Input Voltage
208V, 230V, 240V
Input Connections
Hard wire 3-wire (1P + N + E), Hard wire 3-wire (2P + E)
APC WW 10KVA Isolation Transformer
The Step-Down Transformer converts high voltage (208 or 200 VAC) output into low voltage (120 or 100 VAC) output for powering low voltage AC equipment.
Includes: Documentation CD, Hardwire panel, Installation guide, Mounting hardware, Rack mounting brackets, User manual
-
Rack-Mountable
Occupys only 1U of valuable rack space. Puts the power where it is needed most - in the rack near the equipment.
-
Transformer for Step-down or Step-up or Isolation
Step down transformer placed upstream of the UPS to avoid inrush current and saturation eliminating need to oversize transformer
Product Distribution
United Arab Emirates, Afghanistan, Antigua & Barbuda, Anguilla, Albania, Armenia, Netherlands Antilles, Angola, Argentina, Austria, Australia, Azerbaijan, Bosnia & Herzegovina, Barbados, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, Bermuda, Bolivia, Brazil, Bahamas, Botswana, Belarus, Belize, Canada, Congo - Kinshasa, Switzerland, Côte d’Ivoire, Chile, Cameroon, China, Colombia, Costa Rica, Cyprus, Czechia, Germany, Djibouti, Denmark, Dominica, Dominican Republic, Algeria, Ecuador, Estonia, Egypt, Eritrea, Spain, Ethiopia, Finland, Fiji, Gabon, Grenada, Georgia, French Guiana, Ghana, Gambia, Guadeloupe, Greece, Guatemala, Guyana, Hong Kong SAR China, Honduras, Croatia, Haiti, Hungary, Indonesia, Ireland, Israel, India, Iraq, Iceland, Italy, Jamaica, Jordan, Japan, Kenya, Cambodia, St. Kitts & Nevis, South Korea, Kuwait, Cayman Islands, Kazakhstan, Lebanon, St. Lucia, Liberia, Lithuania, Luxembourg, Latvia, Morocco, Madagascar, North Macedonia, Mali, Myanmar (Burma), Mongolia, Martinique, Mauritania, Malta, Mauritius, Malawi, Mexico, Malaysia, Mozambique, Namibia, Nigeria, Nicaragua, Netherlands, Norway, Oman, Panama, Peru, Philippines, Pakistan, Poland, Puerto Rico, Portugal, Paraguay, Réunion, Romania, Rwanda, Saudi Arabia, Sweden, Singapore, Slovenia, Slovakia, Sierra Leone, Senegal, Somalia, Suriname, El Salvador, Turks & Caicos Islands, Togo, Thailand, Tajikistan, Turkmenistan, Tunisia, Turkey, Trinidad & Tobago, Taiwan, Tanzania, Ukraine, Uganda, United States, Uruguay, Uzbekistan, St. Vincent & Grenadines, Venezuela, U.S. Virgin Islands, Vietnam, Yemen, Mayotte, South Africa, Zambia, Zimbabwe
Output
Efficiency at Full Load
95 % %
Maximum Total Current Draw
60
Input
Input frequency
45 - 65 Hz
Efficiency at Full Load
95 % %
Load Capacity
10000VA
Maximum Input Current
60A
Maximum Line Current
60A
Physical
Maximum Height
175MM, 17.5CM
Maximum Width
432MM, 43.2CM
Maximum Depth
749MM, 74.9CM
Net Weight
100.0KG
Shipping weight
124.74KG
Shipping Height
406MM, 40.6CM
Shipping Width
600MM, 60.0CM
Shipping Depth
1000MM, 100.0CM
Color
Black
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0 - 3048meters
Storage Temperature
-25 - 65 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0 - 15240meters
Conformance
Approvals
CSA, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, UL listed
Standard warranty