APC Back-UPS 600VA, 120V, AVR, LAM, 4 NEMA outlets
BX600L-LM Features
Key Features
Run time for load
Min-max
W
Run time for load
Enter the total load (power draw) of all devices to be protected by the UPS here. Based on the value entered we will estimate the run time that you will have during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.
—
The total load (power draw) entered exceeds the maximum value for this product (300 W)
Please enter load to see estimated run time
The total load (power draw) entered is less than the minimum value for this product ({} W)
Max. Capacity Used
Max. Capacity Used
The maximum percentage of UPS capacity used to support your specified load.
—
Please enter load to see calculated "Max. Capacity Used"
Output power capacity
300 Watts
/ 600VA
Output Connections
(4)
NEMA 5-15R
(Battery Backup)
Nominal Output Voltage
120V
Nominal Input Voltage
120V
Input Connections
NEMA 5-15P
Cord Length
1.2meters
Maximum Input Current
8.0A
APC Back-UPS 600VA, 120V, AVR, LAM, 4 NEMA outlets
Battery Backup & Surge Protector for Electronics and Computers
-
Audible alarms
Provides notification of changing utility power and UPS power conditions
-
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
-
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
-
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
-
Overload protection
Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
-
Safety-agency approved
The UPS is UL1778 Listed
Back-UPS Features & Benefits
Marketing features
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Manageability
LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Availability
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Product Distribution
Antigua and Barbuda, Anguilla, Netherlands Antilles, Argentina, Aruba, Bermuda, Bolivia, Bahamas, Belize, Chile, Colombia, Costa Rica, Dominica, Dominican Republic, Ecuador, Grenada, Guatemala, Guyana, Honduras, Haiti, Saint Kitts And Nevis, Cayman Islands, Saint Lucia, Mexico, Nicaragua, Panama, Peru, Puerto Rico, Paraguay, El Salvador, Trinidad and Tobago, Uruguay, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands
Output
Max Configurable Power (Watts)
300 Watts
/ 600VA
Output Frequency (sync to mains)
60 Hz +/- 3 Hz Sync to mains
Topology
Line interactive
Waveform type
Stepped approximation to a sinewave
Transfer Time
6 ms typical : 10 ms maximum
Input
Input frequency
60 Hz +/- 5 Hz
Input voltage range for main operations
88 - 143V
Number of Power Cords
1
Type of Input Protection Required
GL fuse
Input Power Factor at Full Load
0.5
Batteries & Runtime
Battery type
Lead-acid battery
Included Battery Modules
1
Typical recharge time
6hour(s)
Replacement Battery
Expected Battery Life (years)
2 - 4
Battery Charge Power (Watts)
12 Watts
Runtime
Efficiency
Communications & Management
Control panel
LED Status display with on line : on battery
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating
160Joules
Physical
Maximum Height
141MM, 14.1CM
Maximum Width
101MM, 10.1CM
Maximum Depth
300MM, 30.0CM
Net Weight
4.33KG
Shipping weight
4.58KG
Shipping Height
223MM, 22.3CM
Shipping Width
143MM, 14.3CM
Shipping Depth
347MM, 34.7CM
Color
Black
Master Carton Dimensions (Length x Width x Height)
356 x 152 x 229MM
Master Carton Weight
4.6
Pallet Dimensions
47 x 39 x 45inches
Pallet Weight
892.87lbs.
SCC Codes
40731304323189
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0 - 609.6meters
Storage Temperature
-20 - 50 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0 - 4572meters
Audible noise at 1 meter from surface of unit
40.0dBA
Conformance
Approvals
cTUVus, NOM
Standard warranty
2 years repair or replace
Sustainable Offer Status
RoHS
Compliant