Nos marques

APC - Rack pdu switched 1u 15a 100 120v

APC - Rack pdu switched 1u 15a 100 120v Avant gauche
APC - Rack pdu switched 1u 15a 100 120v Avant gauche
APC - Rack pdu switched 1u 15a 100 120v Avant gauche
APC - Rack pdu switched 1u 15a 100 120v Avant gauche
APC - Rack pdu switched 1u 15a 100 120v Avant gauche
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Back
APC - Rack pdu switched 1u 15a 100 120v Back
APC - Rack pdu switched 1u 15a 100 120v Detailed
APC - Rack pdu switched 1u 15a 100 120v Avant gauche
APC - Rack pdu switched 1u 15a 100 120v Avant gauche
APC - Rack pdu switched 1u 15a 100 120v Avant gauche
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Avant droit
APC - Rack pdu switched 1u 15a 100 120v Back
APC - Rack pdu switched 1u 15a 100 120v Back
APC - Rack pdu switched 1u 15a 100 120v Detailed
RoHS
  • This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality ...

  • Inclut: Support(s) de retenue de câble, Supports pour montage horizontal, Guide d'installation, User manual

Voir la présentation du produit
Nos partenaires

AP7900B Caractéristiques

Principales fonctionnalités

Hauteur du rack
1U
Connexions de sortie
(8) NEMA 5-15R
Tension nominale de sortie
120V
Tension d’Entrée Nominale
100V, 120V
Type de connexion en entrée
NEMA 5-15P
Longueur du cordon
3.7mètres
APC - Rack pdu switched 1u 15a 100 120v
This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality. The output and input connections are (8)5-15. Network management capabilities allow you to configure and manage rack PDUs from remote locations. It has has a local current monitoring display that gives a visible warning in case of an overload. The remote individual outlet control provides real-time monitoring of connected loads. It has a multi-tier user access that enables you to restrict unauthorized use of outlets. This rack has a single input power source making it easy to install.
Inclut: Support(s) de retenue de câble, Supports pour montage horizontal, Guide d'installation, User manual

Unités de distribution d'alimentation en rack commuté NetShelter Caractéristiques et avantages

Simplicité de gestion

Outlet Level Grouping
Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility.
Seuils de déclenchement de l'alarme
Définissez des seuils d’alarme afin d’éviter la surcharge des circuits. Des alarmes réseau et visuelles notifient les problèmes potentiels à l’utilisateur.
1% Metering Accuracy
Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs.
Partage de port réseau
Permet de raccorder quatre onduleurs en rack au moyen des ports d'entrée et de sortie, si bien qu'une seule connexion réseau est nécessaire.
Fonctions de gestion de réseau
Interfaces de gestion de réseau riches en fonctionnalités qui assurent une gestion standard via le Web, SNMP et Telnet. Permet aux utilisateurs d’accéder aux unités, de les configurer et de les gérer à partir d’emplacements distants et de gagner ainsi un temps précieux. A cette fonctionnalité est associée la possibilité de mettre à niveau facilement et rapidement le microprogramme via un téléchargement réseau vers les unités installées pour des améliorations futures du produit.
Accès multi-utilisateurs
Prise en charge de quatre niveaux d'accès maximum (Administrateur, Utilisateur du dispositif, Utilisateur en lecture seule, Utilisateur Réseau uniquement) et demande d'un nom d'utilisateur et d'un mot de passe.
EcoStruxure IT Ready
Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere.
Seuils de déclenchement de l'alarme
Définissez des seuils d'alarme afin d'éviter la surcharge des circuits. Des alarmes réseau et visuelles signalent les problèmes potentiels à l'utilisateur. (Remarque : uniquement disponible sur les unités dotées de capacités de surveillance du courant. Veuillez consulter les spécifications de SKU pour connaître la disponibilité)
Gigabit Ethernet Connectivity
9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity.
Enhanced Cybersecurity
9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind.

Disponibilité

C13/C15 and C19/C21 Hybrid Outlets
Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.
Hydraulic Magnetic Circuit Breakers
Provide increased availability by maintaining trip current over a wide temperature range.
60C Operating Temperature
All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).
High Retention Outlets
With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.
Field-replaceable NMC
Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.

Souplesse

Mémoire flash extensible
Mettez facilement et rapidement à niveau votre micrologiciel par téléchargement via le réseau afin de bénéficier des futures améliorations de produit. Élimine la nécessité de remplacer les produits déjà installés sur le terrain lorsque de nouvelles fonctions sont disponibles. (Remarque : unités mises en réseau uniquement)

Adaptabilité

Source d'alimentation en entrée unique
Fournit l'alimentation d'un fouet de branchement à plusieurs équipements montés en rack. Permet un gain de temps et d'argent durant l'installation en utilisant un fouet de branchement et des connexions standard.
Montable en rack
Possibilités de montage horizontal, vertical et sans aucun outil. Amène l’alimentation là où elle est le plus utile : dans les racks.
Large éventail de connexions d'entrée et de sortie
La gamme de produit comprend diverses connexions d'entrée et de sortie afin de distribuer une alimentation de 120, 208 ou 230 V à plusieurs sorties. La disponibilité de diverses entrées et sorties permet aux utilisateurs de s'adapter à différents besoins électriques. APC propose des unités délivrant jusqu'à 5,7 kW via un seul fouet de branchement.

Distribution des produits

Antigua et Barbuda, Anguilla, Antilles Néerlandaises, Argentine, Autriche, Aruba, Barbade, Belgique, Bermudes, Bolivie, Bahamas, Bélize, Canada, Colombie, Costa Rica, Serbie et Monténégro, République Tchèque, Allemagne, Dominique, République Dominicaine, Equateur, France, Grenade, Grèce, Guatemala, Guyana, Honduras, Haïti, Italie, Jamaïque, Japon, Saint-Christophe-et-Niévès, Îles Caïmans, Sainte-Lucie, Mexique, Nicaragua, Pays-Bas, Panama, Pérou, Porto Rico, Paraguay, Slovaquie, El Salvador, Turquie, Trinité-et-Tobago, Taiwan, Etats-Unis, Uruguay, Saint-Vincent-et-les Grenadines, Vénézuela, Iles Vierges Américaines

Sortie

Dessin de courant total maximal
15

Entrée

Fréquence d'entrée
90 - 264 V
Tension d'entrée acceptable
100 - 120VAC
Nombre de cordons d'alimentation
1
Capacité de charge
1440VA
Courant d'entrée maximal
15A
Courant de catégorie réglementaire en entrée (Amérique du Nord)
12A

Physique

Hauteur max.
44mm, 4.4cm
Largeur max.
445mm, 44.5cm
Profondeur max.
108mm, 10.8cm
Poids net
2.27kg
Poids avec emballage
3.45kg
Hauteur de transport
70mm, 7.0cm
Largeur de transport
470mm, 47.0cm
Profondeur de transport
343mm, 34.3cm
Couleur
Noir

Environnemental

Température de fonctionnement
0 - 45 °C
Humidité relative en fonctionnement
0 - 95 %
Altitude en fonctionnement
0 - 3048mètres
Température de stockage
-25 - 65 °C
Humidité relative de stockage
0 - 95 %
Altitude de stockage
0 - 15240mètres

Conformité

Approbation
Répertorié cUL, FCC partie 15 classe A, ICES-003, listé UL
Garantie standard
1 an, réparation ou remplacement

Offre durable Etat

RoHS
Conforme

Options

Services