Symmetra PX

10-500kVA -480V and 16-500kVA -400V high performance, right-sized, modular, scalable, 3 phase UPS power protection with ultra high availability and efficiency for any size data center or high density power zone.

10kVA to 500kVA
The Symmetra PX is a world class, redundant, scalable, 3 Phase UPS power protection system designed to cost effectively provide high levels of availability. Seamlessly integrating into today's state-of-the-art data center designs, the Symmetra PX is a true modular system. Made up of dedicated and redundant modules--power, intelligence, battery and bypass, all engineered into a design that is easily and efficiently serviceable, this architecture can scale power and runtime as demand grows or as higher levels of availability are required. Symmetra PX serves as the core power train that drives InfraStruXure® systems for small and medium data centers but can also power individual "zones" of larger data centers. Highly manageable, the Symmetra PX features self-diagnostic capabilities and standardized modules which mitigate the risk of human error resulting in increased overall data center reliability.

Read More
Products Part Number Est. Runtime (hrs:Min) Compare
Product Symmetra PX 160kW 400V w/ Integrated Modular Distribution Part Number SY160K160H-PD Est. Runtime (hrs:Min) 6:55
How to buy
Product Symmetra PX 160kW, without Bypass, Distribution, or Batteries, 400V Part Number SY160K160H-NB Est. Runtime (hrs:Min) N/A
How to buy
Product Symmetra PX 160kW, 400V Part Number SY160K160H Est. Runtime (hrs:Min) 6:55
How to buy
Product Symmetra PX 200kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution Part Number SY200K250DR-PD Est. Runtime (hrs:Min) 9:31
How to buy
Product Symmetra PX 200kW Scalable to 250kW without Maintenance Bypass or Distribution-Parallel Capable Part Number SY200K250D Est. Runtime (hrs:Min) 9:31
How to buy
Product Symmetra PX 250kW Scalable to 500kW w/ right mounted MBwD Part Number SY250K500DR-PD Est. Runtime (hrs:Min) 11:34
How to buy
Product Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution Part Number SY250K500DL-PD Est. Runtime (hrs:Min) 11:34
How to buy
Product Symmetra PX 250kW Scalable to 500kW without Maintenance Bypass or Distribution-Parallel Capable Part Number SY250K500D Est. Runtime (hrs:Min) 11:34
How to buy
Product Symmetra PX 300kW Scalable to 500kW with Right Mounted Maintenance Bypass and Distribution Part Number SY300K500DR-PD Est. Runtime (hrs:Min) 14:22
How to buy
Product Symmetra PX 300kW Scalable to 500kW without Maintenance Bypass or Distribution-Parallel Capable Part Number SY300K500D Est. Runtime (hrs:Min) 14:22
How to buy
Product Symmetra PX 400kW Scalable to 500kW without Maintenance Bypass or Distribution-Parallel Capable Part Number SY400K500D Est. Runtime (hrs:Min) 17:51
How to buy
Product Symmetra PX 400kW Scalable to 500kW with Right Mounted Maintenance Bypass and Distribution Part Number SY400K500DR-PD Est. Runtime (hrs:Min) 17:51
How to buy
Product Symmetra PX 500kW Scalable to 500kW with Right Mounted Maintenance Bypass and Distribution Part Number SY500K500DR-PD Est. Runtime (hrs:Min) 20:54
How to buy
Product Symmetra PX 500kW Scalable to 500kW without Maintenance Bypass or Distribution-Parallel Capable Part Number SY500K500D Est. Runtime (hrs:Min) 20:54
How to buy
Product Symmetra PX 500kW Scalable to 500kW with Maintenance Bypass Left & Distribution Part Number SY500K500DL-PD Est. Runtime (hrs:Min) 20:54
How to buy
Page:
  • 1
  • 2
Sustainability
EU CoC for UPS Ensures that UPSs sold in the EU are highly efficient
Availability
Swappable power modules Allows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.
Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Network manageable Provides remote power management of the UPS over the network.
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Configurable for N+1 internal redundancy Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Total Cost of Ownership
5x8 Start-up service included Required for full coverage of factory warranty
Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Fully-rated power kVA equals kW Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
Agility
Scalable power capacity Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
Programmable frequency Ensures compatibility with different input frequencies.
SmartSlot Customize UPS capabilities with management cards.
Manageability
Audible alarms Provides notification of changing utility power and UPS power conditions
Integrates with StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
LED status indicators Quickly understand unit and power status with visual indicators.