Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord

Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord 左前方
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord 左前方
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord 左前方
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord Back
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord Detailed
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord Detailed
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord 左前方
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord Back
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord Detailed
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord Detailed
RoHS
  • APC公司的计量式机架配电单元(PDU)具有主动计量功能,能够进行能源优化和电路保护。用户自定义的报警阈值通过实时本地和远程报警来警告潜在的电路过载,从而能够降低风险。计量式机架PDU能够提供用电数据,可以让数据中心管理人员对于负载平衡和确定IT环境的规模作出明智的决策,从而降低总体拥有成本。计量式机架PDU包括实际功率监控、温度/湿度传感器端口、锁紧型IEC插座以及非常紧凑的断路器。用户可以通过安全的Web、SNMP或Telnet界面来访问和配置机架PDU,使用InfraStruxure ...

  • 包括: 安装指南, 架式安装支架, 安全指南, 串行配置电缆

查看产品概述

AP8886X630 特点

关键特性

输出连接
(12) IEC 60320 C19
(30) IEC 60320 C13
额定输出电压
230V
额定输入电压
400V 3PH
输入端子类型
IEC 60309 32 A 3P + N + E
线缆长度
1.8米
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V, (30) C13 & (12) C19, 10ft Cord
APC公司的计量式机架配电单元(PDU)具有主动计量功能,能够进行能源优化和电路保护。用户自定义的报警阈值通过实时本地和远程报警来警告潜在的电路过载,从而能够降低风险。计量式机架PDU能够提供用电数据,可以让数据中心管理人员对于负载平衡和确定IT环境的规模作出明智的决策,从而降低总体拥有成本。计量式机架PDU包括实际功率监控、温度/湿度传感器端口、锁紧型IEC插座以及非常紧凑的断路器。用户可以通过安全的Web、SNMP或Telnet界面来访问和配置机架PDU,使用InfraStruxure Central(集中管理)、Operations(运行管理)、Capacity(容量管理)和Energy Efficiency(能源效率)软件的APC公司InfraStruXure中央管理平台对这些界面赞赏有加。
包括: 安装指南, 架式安装支架, 安全指南, 串行配置电缆

产品分销

United Arab Emirates, Afghanistan, Antigua and Barbuda, Anguilla, Albania, Armenia, Netherlands Antilles, Angola, Argentina, Austria, Australia, Aruba, Azerbaijan, Bosnia and Herzegovina, Barbados, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, Bermuda, Bolivia, Brazil, Bahamas, Botswana, Belarus, Belize, The Democratic Republic Of Congo, Switzerland, Côte d'Ivoire, Chile, Cameroon, China, Colombia, Costa Rica, Cyprus, Czech Republic, Germany, Djibouti, Denmark, Dominica, Dominican Republic, Algeria, Ecuador, Estonia, Egypt, Eritrea, Spain, Ethiopia, Finland, Fiji, France, Gabon, Grenada, Georgia, French Guiana, Ghana, Gambia, Guadeloupe, Greece, Guatemala, Guyana, Hong Kong, Honduras, Croatia, Haiti, Hungary, Indonesia, Ireland, Israel, India, Iraq, Iceland, Italy, Jamaica, Jordan, Kenya, Cambodia, Saint Kitts And Nevis, South Korea, Kuwait, Cayman Islands, Lebanon, Saint Lucia, Liberia, Lithuania, Luxembourg, Latvia, Morocco, Madagascar, Macedonia, Mali, Myanmar, Mongolia, Martinique, Mauritania, Malta, Mauritius, Malawi, Mexico, Malaysia, Mozambique, Namibia, Nigeria, Nicaragua, Netherlands, Norway, New Zealand, Oman, Panama, Peru, Philippines, Pakistan, Poland, Puerto Rico, Portugal, Paraguay, Reunion, Romania, Russia, Rwanda, Saudi Arabia, Sweden, Singapore, Slovenia, Slovakia, Sierra Leone, Senegal, Somalia, Suriname, El Salvador, Turks And Caicos Islands, Togo, Thailand, Tajikistan, Turkmenistan, Turkey, Trinidad and Tobago, Tanzania, Ukraine, Uganda, Uruguay, Uzbekistan, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands, Vietnam, Yemen, Mayotte, South Africa, Zambia, Zimbabwe

输出

常通插座
42
过载保护
是的
最大总电流消耗
32

输入

输入频率
90 - 264 V
承载能力
22000VA
最大输入电流
32A
最大线路电流
32A

物理参数

1829mm, 182.9cm
56mm, 5.6cm
51mm, 5.1cm
净重
8.72kg
毛重
11.55kg
装运高度
2050mm, 205.0cm
装运宽度
170mm, 17.0cm
装运深度
112mm, 11.2cm
颜色
黑色

环境

工作温度
0 - 50 °C
工作相对湿度
5 - 95 %
操作高度
0 - 3048米
存储温度
-25 - 65 °C
存储相对湿度
5 - 95 %
存储高度
0 - 15240米

相符性

管理机构认证
EN 55022 A 级, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 部分 A 级, ICES-003, VCCI A 类, VDE
标准质保
2年内维修或更换

可持续提供状态\

RoHS
符合

选项

服务