  • Extremely reliable service bypass panels designed for APC InfraStruXure® Type A, Smart-UPS, and Symmetra UPS products.

  • Includes: Rack mounting brackets, User manual

View Product Overview

SBP1500RM Features

Key Features

Rack Height
2U
Output Connections
(8) NEMA 5-15R
Nominal Output Voltage
120V
Nominal Input Voltage
120V
Input Connections
NEMA 5-15P
Cord Length
2.4meters
APC SERVICE BYPASS PDU, 120V 15AMP W/ (8) NEMA 5-15R
Extremely reliable service bypass panels designed for APC InfraStruXure® Type A, Smart-UPS, and Symmetra UPS products.
Includes: Rack mounting brackets, User manual
  • Quick Transfer Rate
    Transfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.
  • Wrap Around System Bypass
    (3) Breaker maintenance bypass panel to isolate the UPS from the critical load

Product Distribution

Antigua and Barbuda, Anguilla, Netherlands Antilles, Aruba, Barbados, Bermuda, Brazil, Belize, Canada, Colombia, Costa Rica, Dominican Republic, Ecuador, Guatemala, Guyana, Honduras, Jamaica, Mexico, Nicaragua, Panama, Peru, Puerto Rico, El Salvador, Trinidad and Tobago, United States, Venezuela, U.S. Virgin Islands

Technical Specifications

Output

Efficiency at Full Load
99 % %
Always on Outlets
8
Overload Protection
Yes
Cord Length
1.2meters
Maximum Total Current Draw
15

Input

Input frequency
50/60 Hz
Acceptable Input Voltage
100 - 125VAC
Number of Power Cords
1
Efficiency at Full Load
99 % %
Load Power Factor Range
0 to 1
Load Capacity
1500VA
Maximum Input Current
15A
Maximum Line Current
15A

Physical

Maximum Height
89MM, 8.9CM
Maximum Width
432MM, 43.2CM
Maximum Depth
76MM, 7.6CM
Net Weight
2.95KG
Shipping weight
3.8KG
Shipping Height
151MM, 15.1CM
Shipping Width
463MM, 46.3CM
Shipping Depth
295MM, 29.5CM
Color
Black
Units per Pallet
56.0

Environmental

Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0 - 4572meters
Storage Temperature
-15 - 45 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0 - 15240meters

Conformance

Approvals
TÜV
Standard warranty
2 years repair or replace

Options

Services