InRow Chilled Water Cooling

Close-coupled, chilled water cooling for medium to large data centers

Explore InRow RC600 in 3D animation.
The InRow Chilled Water family closely couples the cooling with the heat source, improving predictability and efficiency. Intelligent controls actively adjust to match the load, addressing the dynamic demands of today's IT environments. Available in various configurations, these units meet the diverse requirements for data center cooling. IT operators looking to improve efficiency or deploy higher density equipment will benefit from the modular design of the InRow Chilled Water products

Read More
Manageability
Real-Time Capacity Monitoring Real-time display of current and available cooling.
Building management system integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Agility
Modular design Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Casters Provides flexibility to move the unit to wherever cooling is required.
Serviceability
Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Availability
Rack inlet control Rack inlet control guarantees inlet temperature to IT equipment.
Dual A-B power inputs Draws power from the UPS for power protection with dual feeds for redundancy.
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Total Cost of Ownership
Row-based architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.