APC Back-UPS ES 6 Outlet 425VA, 120V, LAM

APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Front Left
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Front Left
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Front Left
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Front Right
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Application
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Detailed
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Front Left
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Front Right
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Application
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM Detailed
  • Battery Backup & Surge Protector for Electronics and Computers

  • Includes: User Manual

View Product Overview
Replacement battery
User replaceable battery not available

BE425M-LM Features

Key Features

Run time for load W
Run time for load
Enter the total load (power draw) of all devices to be protected by the UPS here. Based on the value entered we will estimate the run time that you will have during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.

The total load (power draw) entered exceeds the maximum value for this product (255W)

Please enter load to see estimated run time

Max. Capacity Used
Max. Capacity Used
The maximum percentage of UPS capacity used to support your specified load.

Please enter load to see calculated "Max. Capacity Used"

Output power capacity
255 Watts / 425VA
Output Connections
(4) NEMA 5-15R (Battery Backup)
(2) NEMA 5-15R (Surge Protection)
Nominal Output Voltage
120V
Nominal Input Voltage
120V
Input Connections
NEMA 5-15P
Cord Length
1.52meters
Maximum Input Current
5.0A
APC Back-UPS ES 6 Outlet 425VA, 120V, LAM
Battery Backup & Surge Protector for Electronics and Computers
Includes: User Manual
  • Audible alarms
    Provides notification of changing utility power and UPS power conditions
  • Building Wiring Fault Indicator
    This LED informs users of potentially dangerous wiring problems in the wall circuit.

Back-UPS Features & Benefits

Manageability

Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status display
Quickly understand unit and power status with visual indicators.

Availability

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Protection

Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.

Safety

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Marketing features

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Product Distribution

Antigua and Barbuda, Anguilla, Netherlands Antilles, Argentina, Aruba, Barbados, Bermuda, Bolivia, Bahamas, Belize, Chile, Colombia, Costa Rica, Cuba, Dominica, Dominican Republic, Ecuador, Falkland Islands, Grenada, Guatemala, Guyana, Honduras, Haiti, Jamaica, Saint Kitts And Nevis, Cayman Islands, Saint Lucia, Mexico, Nicaragua, Panama, Peru, Puerto Rico, Paraguay, El Salvador, Trinidad and Tobago, Uruguay, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands

Technical Specifications

Output

Max Configurable Power (Watts)
255 Watts / 425VA
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Topology
Standby
Waveform type
Square wave
Transfer Time
6ms typical : 10ms maximum

Input

Input frequency
50 Hz +/- 3 Hz, 60 Hz +/- 3 Hz
Input voltage range for main operations
88 - 139V
Number of Power Cords
1

Batteries & Runtime

Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time
8hour(s)
Expected Battery Life (years)
3 - 5
Battery Charge Power (Watts)
6 Watts
Battery Volt-Amp-Hour Capacity
47

Communications & Management

Control panel
LED Status display with On Line : On Battery
Audible Alarm
Alarm when on battery : distinctive low battery alarm

Surge Protection and Filtering

Surge energy rating
180Joules

Physical

Maximum Height
140MM, 14.0CM
Maximum Width
253MM, 25.3CM
Maximum Depth
105MM, 10.5CM
Net Weight
2.6KG
Shipping weight
3.0KG
Shipping Height
220MM, 22.0CM
Shipping Width
315MM, 31.5CM
Shipping Depth
140MM, 14.0CM
Color
Black
Master Carton Units
2.0
Master Carton Weight
6.5
Units per Pallet
96.0
SCC Codes
1073130432936 4

Environmental

Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0-3000meters
Storage Temperature
-20 - 50 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0-15000meters

Conformance

Approvals
cTUVus, FCC Part 15 Class B
Equipment protection policy
Lifetime : $75000
Standard warranty
3 years repair or replace

Sustainable Offer Status

RoHS
Compliant
REACH
REACH: Contains SVHCs