APC Smart-UPS Charge Mobile Battery for Microsoft Surface Hub 2

APC Smart-UPS Charge Mobile Battery for Microsoft Surface Hub 2 Front Left
APC Smart-UPS Charge Mobile Battery for Microsoft Surface Hub 2 Front Left
APC Smart-UPS Charge Mobile Battery for Microsoft Surface Hub 2 Front Left
APC Smart-UPS Charge Mobile Battery for Microsoft Surface Hub 2 Application
APC Smart-UPS Charge Mobile Battery for Microsoft Surface Hub 2 Miscellaneous
APC Smart-UPS Charge Mobile Battery for Microsoft Surface Hub 2 Detailed
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 99ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 71ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • APC™ Smart-UPS Charge Mobile Battery is a lithium-ion battery system designed to power Microsoft Surface Hub 2 on-the-go for over 100 minutes, so you stay connected...

  • Includes: Qty 1 - DC Cable, Qty 1 - Detachable IEC C13 to C14 power cord, Qty 1 - Set of (4) Screws, USB cable, User Manual

View Product Overview

CSH2 Features

APC Smart-UPS Charge Mobile Battery for Microsoft Surface Hub 2
APC™ Smart-UPS Charge Mobile Battery is a lithium-ion battery system designed to power Microsoft Surface Hub 2 on-the-go for over 100 minutes, so you stay connected regardless of the location.
Includes: Qty 1 - DC Cable, Qty 1 - Detachable IEC C13 to C14 power cord, Qty 1 - Set of (4) Screws, USB cable, User Manual
  • LED status indicators
    Quickly understand unit and power status with visual indicators.
  • Lithium-ion battery
    Lithium-ion batteries provide twice the service life of a typical lead acid battery and are small, light and environmentally friendly.
  • USB connection
    Use your PC to access additional power protection and management features for your UPS via a USB Port.

Smart-UPS Features & Benefits

Serviceability

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Resettable circuit breakers
Enables a quick recovery from overload events.

Manageability

USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Serial connectivity
Provides management of the UPS via a serial port.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Network manageable
Provides remote power management of the UPS over the network.
LED status indicators
Quickly understand unit and power status with visual indicators.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.

Availability

Disconnected battery notification
Warns when a battery is not available to provide backup power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

Safety

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Adaptability

Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Marketing Features

Smarter productivity  with ability to tailor to your specific application needs
Intuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Avoids costly power problems by keeping your IT equipment and data safe and available
Network grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systems
Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management
Patented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.
Save time with easy and convenient remote accessibility
Network manageable via serial, USB or optional ethernet. Includes Powerchute® Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.

Product Distribution

United Arab Emirates, Austria, Belgium, Canada, Switzerland, Germany, Denmark, Spain, Finland, France, United Kingdom, Hong Kong, Ireland, Italy, South Korea, Luxembourg, Malaysia, Netherlands, Norway, Portugal, Qatar, Sweden, Singapore, Thailand, Taiwan, United States

Output

Output power capacity
388Watts / 400VA
Max Configurable Power (Watts)
388Watts / 400VA
Nominal Output Voltage
24VDC
Neutral Output Current
8A
Output Voltage Note
Output voltage follows Input voltage
Efficiency at Full Load
90.0 %
Other Output Voltages
100, 120, 220
Waveform type
DC
Output Voltage Tolerance
+/- 5% after 2ms

Input

Nominal Input Voltage
100V, 120V, 230V
Input frequency
40 - 70 Hz
Input Connections
C-13
Efficiency at Full Load
90.0 %
Maximum Input Current
8.0A

Batteries & Runtime

Battery type
Li-ion
Included Battery Modules
1
Typical recharge time
1.5hour(s)
End of Discharge Maximum Battery Current
12.0A
Expected Battery Life (years)
3 - 5
DC Overcurrent Protection
15A
Battery Volt-Amp-Hour Capacity
2
Efficiency in Battery Operation
90.0 %

Communications & Management

Interface Port(s)
USB

Physical

Maximum Height
90MM, 9.0CM
Maximum Width
430MM, 43.0CM
Maximum Depth
280MM, 28.0CM
Net Weight
11.0KG
Shipping weight
13.0KG
Shipping Height
270MM, 27.0CM
Shipping Width
650MM, 65.0CM
Shipping Depth
515MM, 51.5CM
Units per Pallet
8.0

Environmental

Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 85 %
Storage Temperature
-20 - 60 °C
Storage Relative Humidity
0 - 95 (non-condensing) %
Audible noise at 1 meter from surface of unit
31.0dBA

Conformance

Approvals
California (CEC) Battery Charger
Standard warranty
3 years repair or replace

Options

Services