APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE.

APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Front Left
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Front Left
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Front Left
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Front Right
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Front Straight
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Back
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Front Left
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Front Right
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Front Straight
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE. Back
RoHS
  • Includes: User manual

View Product Overview

SYBBE Features

Key Features

Rack Height
42U
APC SYMMETRA PX 250/500kW BATTERY BREAKER ENCLOSURE.
Includes: User manual
  • Global product offering
    Standardization of power distribution units across all corporate locations is easy - a variety of 1-phase and 3-phase Power Distribution Modules address the unique power requirements of data centers around the world.
  • Global safety approvals
    UL60950, CSA60950, IEC60950, EN60950 safety approvals. Meets IEC 61000-4-5 Immunity To Surge, and GR-1089-CORE, Section 4, Lightning and AC Power Faults standards.
  • Safety-agency approved
    The UPS is UL1778 Listed
  • Top and bottom cable entry (standard)
    Flexibility that allows the customer to decide - and at no extra cost.

Product Distribution

United Arab Emirates, Afghanistan, Antigua and Barbuda, Anguilla, Albania, Armenia, Netherlands Antilles, Angola, Argentina, Aruba, Azerbaijan, Bosnia and Herzegovina, Barbados, Belgium, Burkina Faso, Bahrain, Burundi, Benin, Bermuda, Bolivia, Brazil, Bahamas, Botswana, Belarus, Belize, Canada, The Democratic Republic Of Congo, Côte d'Ivoire, Chile, Cameroon, Colombia, Costa Rica, Cyprus, Czech Republic, Djibouti, Denmark, Dominica, Dominican Republic, Ecuador, Estonia, Eritrea, Ethiopia, Fiji, France, Gabon, United Kingdom, Grenada, Georgia, French Guiana, Ghana, Gambia, Guadeloupe, Guatemala, Guyana, Hong Kong, Honduras, Croatia, Haiti, India, Iraq, Iceland, Italy, Jamaica, Jordan, Kenya, Cambodia, Saint Kitts And Nevis, South Korea, Kuwait, Cayman Islands, Lebanon, Saint Lucia, Liberia, Lithuania, Luxembourg, Latvia, Morocco, Madagascar, Mali, Myanmar, Mongolia, Martinique, Mauritania, Malta, Mauritius, Malawi, Mexico, Mozambique, Namibia, Nicaragua, Norway, Oman, Panama, Peru, Philippines, Pakistan, Puerto Rico, Paraguay, Reunion, Romania, Rwanda, Slovenia, Sierra Leone, Senegal, Somalia, Suriname, El Salvador, Turks And Caicos Islands, Togo, Thailand, Tajikistan, Turkmenistan, Turkey, Trinidad and Tobago, Tanzania, Ukraine, Uganda, United States, Uruguay, Uzbekistan, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands, Yemen, Mayotte, Zambia, Zimbabwe

Technical Specifications

Batteries & Runtime

Battery type
External battery system

Physical

Maximum Height
1991MM, 199.1CM
Maximum Width
600MM, 60.0CM
Maximum Depth
1070MM, 107.0CM
Net Weight
327.0KG
Shipping weight
365.0KG
Shipping Height
2135MM, 213.5CM
Shipping Width
750MM, 75.0CM
Shipping Depth
1210MM, 121.0CM
Color
Black
Units per Pallet
1.0

Environmental

Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Operating Elevation
0 - 1015.9meters
Storage Temperature
-15 - 40 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0 - 4572meters

Conformance

Approvals
C-Tick, CE, RCM, UL listed
Standard warranty
1 year repair or replace

Sustainable Offer Status

RoHS
Compliant

Options

Services