InRow Pumped Refrigerant

Close-coupled, pumped refrigerant cooling for medium to large data center

The InRow Pumped Refrigerant product design closely couples the cooling with the IT heat load. This design prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available in overhead or floor mounted configurations, these products are designed to reduce power and whitespace consumption without introducing chilled water next to IT equipment. Data center operators looking to improve efficiency or deploy high density servers will benefit from the modular design of the InRow Pumped Refrigerant cooling products. The intelligent controls of the InRow Pumped Refrigerant cooling products actively adjust fan speed and refrigerant flow, with no minimum loading, to match the IT heat load to maximize efficiency and address the dynamic demands of today's IT environments.

Read More
No Results
Availability
No minimum heat load requirement Refrigerant cooling system will operate from 0 - 100% of the design capacity
Dual A-B Power Inputs Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control Rack inlet control guarantees inlet temperature to IT equipment.
Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Agility
Scalable densities Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Modular design Modular design provides scalable solutions to add cooling as demand increases.
Total Cost of Ownership
Row-based architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
Manageability
Building management system integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Real-Time Capacity Monitoring Real-time display of current and available cooling.
Serviceability
Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.