APC Back-UPS 700VA, 120V, AVR, USB Charging, NEMA Sockets

APC Back-UPS 700VA, 120V, AVR, USB Charging,  NEMA Sockets Front Right
APC Back-UPS 700VA, 120V, AVR, USB Charging,  NEMA Sockets Front Right
APC Back-UPS 700VA, 120V, AVR, USB Charging,  NEMA Sockets Front Right
APC Back-UPS 700VA, 120V, AVR, USB Charging,  NEMA Sockets Front Straight
APC Back-UPS 700VA, 120V, AVR, USB Charging,  NEMA Sockets Back
APC Back-UPS 700VA, 120V, AVR, USB Charging,  NEMA Sockets Front Right
APC Back-UPS 700VA, 120V, AVR, USB Charging,  NEMA Sockets Front Straight
APC Back-UPS 700VA, 120V, AVR, USB Charging,  NEMA Sockets Back
RoHS
  • Battery Backup & Surge Protector for Electronics and Computers

View Product Overview

BVX700LU-LM Features

Key Features

Run time for load
Min-max
W
Run time for load
Enter the total load (power draw) of all devices to be protected by the UPS here. Based on the value entered we will estimate the run time that you will have during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.

The total load (power draw) entered exceeds the maximum value for this product (360 W)

Please enter load to see estimated run time

The total load (power draw) entered is less than the minimum value for this product ({} W)

Max. Capacity Used
Max. Capacity Used
The maximum percentage of UPS capacity used to support your specified load.

Please enter load to see calculated "Max. Capacity Used"

Output power capacity
360 Watts / 700VA
Output Connections
(4) NEMA 5-15R (Battery Backup)
Input Connections
NEMA 5-15P
Cord Length
1.5meters
APC Back-UPS 700VA, 120V, AVR, USB Charging, NEMA Sockets
Battery Backup & Surge Protector for Electronics and Computers

Back-UPS Features & Benefits

Availability

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Manageability

Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status display
Quickly understand unit and power status with visual indicators.

Marketing features

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Protection

Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .

Safety

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Product Distribution

Antigua and Barbuda, Anguilla, Netherlands Antilles, Argentina, Aruba, Barbados, Bermuda, Bolivia, Brazil, Bahamas, Belize, Chile, Colombia, Costa Rica, Cyprus, Dominica, Dominican Republic, Ecuador, Grenada, Guatemala, Guyana, Honduras, Haiti, Saint Kitts And Nevis, Cayman Islands, Saint Lucia, Mexico, Nicaragua, Panama, Peru, Puerto Rico, Paraguay, Suriname, El Salvador, Turks And Caicos Islands, Trinidad and Tobago, Uruguay, Saint Vincent And The Grenadines, Venezuela, U.S. Virgin Islands

Technical Specifications

Output

Max Configurable Power (Watts)
360 Watts / 700VA
Efficiency at Full Load
97.0 %
Output Frequency (sync to mains)
50/60 Hz +/- 1 Hz Sync to mains
Topology
Line interactive
Waveform type
Stepped approximation to a sinewave
Transfer Time
6 ms typical : 10 ms maximum

Input

Input frequency
50/60 Hz +/- 5 Hz Auto-sensing
Input voltage range for main operations
89 - 145 (120 V) ACV
Number of Power Cords
1
Efficiency at Full Load
97.0 %
Type of Input Protection Required
Circuit breaker
Input Power Factor at Full Load
0.51

Batteries & Runtime

Battery type
Lead-acid battery
Typical recharge time
8hour(s)
Nominal Battery Voltage
12 V
Expected Battery Life (years)
2 - 3

Communications & Management

Control panel
LED Status display with on line : on battery
Audible Alarm
Alarm when on battery : distinctive low battery alarm

Surge Protection and Filtering

Surge energy rating
350Joules

Physical

Maximum Height
138MM, 13.8CM
Maximum Width
98MM, 9.8CM
Maximum Depth
310MM, 31.0CM
Net Weight
4.2KG
Shipping weight
4.6KG
Shipping Height
222MM, 22.2CM
Shipping Width
142MM, 14.2CM
Shipping Depth
346MM, 34.6CM
Color
Black
# of Layers per Pallet
8.0
# of Units per Layer per Pallet
20.0
SCC Codes
10731304417658

Environmental

Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 (Non-condensing) %
Operating Elevation
0 - 3000meters
Storage Temperature
-15 - 40 °C
Storage Relative Humidity
0 - 95 (Non-condensing) %
Storage Elevation
0 - 3000meters
Audible noise at 1 meter from surface of unit
40.0dBA
Protection Class
IP20

Conformance

Approvals
NOM, UL 1778 5th edition

Sustainable Offer Status

RoHS
Compliant

Options