InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz

InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Front Left
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Front Left
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Front Left
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Front Left
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Front Right
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Front Straight
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Back
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Application
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Application
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Miscellaneous
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Miscellaneous
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Miscellaneous
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Miscellaneous
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Miscellaneous
InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz Miscellaneous
  • Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers

  • Includes: Exhaust Duct Kit, Installation Guide, Operations and Maintenance Manual

View Product Overview

ACSC100 Features

InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz
Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers
Includes: Exhaust Duct Kit, Installation Guide, Operations and Maintenance Manual
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Automatic restart
    Returns the unit to its last operating status in the event of a power failure.
  • Dry contact output
    Provides remote notification of failures when used with APC environmental monitoring unit or system.
  • Easy to install
    Innovative design allows for fast, easy installation by almost anybody.
  • Fault-tolerant fan system
    In the event of a fan failure, the remaining fan(s) will continue to operate.
  • Field replaceable components
    Fans and electronics module can be readily replaced without uninstalling the unit.
  • Horizontal airflow pattern
    Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.

InRow Direct Expansion Features & Benefits

Availability

Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Rack inlet temperature control
Reduces the risk of hot spots at the rack level
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Total Cost of Ownership

Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Serviceability

Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Agility

Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Manageability

Microprocessor controller
Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time capacity monitoring
Real-time display of current and available cooling.

Product Distribution

Antigua and Barbuda, Anguilla, Netherlands Antilles, Aruba, Barbados, Bermuda, Brazil, Belize, Canada, Colombia, Costa Rica, Cuba, Dominican Republic, Ecuador, Falkland Islands, Guatemala, Guyana, Honduras, Jamaica, Japan, Cayman Islands, Mexico, Nicaragua, Panama, Peru, Puerto Rico, El Salvador, Trinidad and Tobago, United States, Venezuela, U.S. Virgin Islands

Input

Input frequency
60 Hz
Input Connections
NEMA L6-20P
Number of Power Cords
1
Input Power
2940.0Watts

Communications & Management

Control panel
Multi-function LCD status and control console

Physical

Maximum Height
1991MM, 199.1CM
Maximum Width
300MM, 30.0CM
Maximum Depth
1069MM, 106.9CM
Rack Height
42U
Net Weight
165.92KG
Shipping weight
216.0KG
Shipping Height
2156MM, 215.6CM
Shipping Width
762MM, 76.2CM
Shipping Depth
1138MM, 113.8CM
Color
Black

Environmental

Storage Temperature
0 - 40 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0-4500meters
Audible noise at 1 meter from surface of unit
80.0dBA

Conformance

Approvals
BSMI, EN 55022 Class A, FCC Part 15 Class A, ICES-003, UL Listed, VCCI, VDE
Standard warranty
1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

Sustainable Offer Status

Other Environmental Compliance
China RoHS
Proposition 65 Warning
Available in Documentation tab

General

Air Discharge Patterns
Horizontal
Air Flow
566.34lps
Amp Draw In-Rush
56.0A
Compressor Type
Rotary
Condensate Pump Capacity
0.002lps
Intake Air
Rear Return
Refrigerant Charge
1.36pounds

Options

Services